NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the Field
The protective structure is designed to protect the live force against the impact of a shock wave and projectiles, it cannot be diagnosed by the destructive method which devalues the protective structure by sampling. The authors are looking for a combination of suitable non-destructive technology (N...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-11-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/10/22/8161 |
id |
doaj-eb9b53997fcf4984b599436924c1eb4c |
---|---|
record_format |
Article |
spelling |
doaj-eb9b53997fcf4984b599436924c1eb4c2020-11-25T04:11:11ZengMDPI AGApplied Sciences2076-34172020-11-01108161816110.3390/app10228161NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the FieldZezulová Eva0Hasilová Kamila1Komárková Tereza2Stoniš Patrik3Štoller Jiří4Anton Ondřej5Faculty of Military Technology, University of Defence in Brno, Kounicova 65, 602 00 Brno, Czech RepublicFaculty of Military Leadership, University of Defence in Brno, Kounicova 65, 602 00 Brno, Czech RepublicFaculty of Civil Engineering, Brno University of Technology, Veveří 331/95, 602 00 Brno, Czech RepublicFaculty of Military Technology, University of Defence in Brno, Kounicova 65, 602 00 Brno, Czech RepublicFaculty of Military Technology, University of Defence in Brno, Kounicova 65, 602 00 Brno, Czech RepublicFaculty of Civil Engineering, Brno University of Technology, Veveří 331/95, 602 00 Brno, Czech RepublicThe protective structure is designed to protect the live force against the impact of a shock wave and projectiles, it cannot be diagnosed by the destructive method which devalues the protective structure by sampling. The authors are looking for a combination of suitable non-destructive technology (NDT) methods that would be used in the future to prove the degree of damage to cement-based protective structures after an explosion. This article represents the first part of an experiment designed to verify the applicability of NDT methods, to evaluate the degree of damage of the protective structure in the field. The experiment consists of three parts. The first part is a laboratory verification of the initial material characteristics of the materials used. The first test set of structural elements is made of steel fiber-reinforced concrete. The elements are evaluated using NDT methods and for comparison by destructive laboratory methods. The second part is the impact of structures using explosion and evaluation of the condition of structures using NDT methods in the field. The last part is used to verify the results of the NDT method, which ensures the residual strength of the structure in the laboratory and try to find the relationship between changes in the results of NDT methods and the residual strength. Radiography was included in the introductory and concluding parts of the experiment to verify the results. Although this method is not suitable for using in-situ, it is the only standardized method of the NDT methods used.https://www.mdpi.com/2076-3417/10/22/8161steel fiber-reinforced concrete (SFRC)ultrasonic testingradiographyelectromagnetic testingNDT evaluation in situmilitary fortification construction |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zezulová Eva Hasilová Kamila Komárková Tereza Stoniš Patrik Štoller Jiří Anton Ondřej |
spellingShingle |
Zezulová Eva Hasilová Kamila Komárková Tereza Stoniš Patrik Štoller Jiří Anton Ondřej NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the Field Applied Sciences steel fiber-reinforced concrete (SFRC) ultrasonic testing radiography electromagnetic testing NDT evaluation in situ military fortification construction |
author_facet |
Zezulová Eva Hasilová Kamila Komárková Tereza Stoniš Patrik Štoller Jiří Anton Ondřej |
author_sort |
Zezulová Eva |
title |
NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the Field |
title_short |
NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the Field |
title_full |
NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the Field |
title_fullStr |
NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the Field |
title_full_unstemmed |
NDT Methods Suitable for Evaluation the Condition of Military Fortification Construction in the Field |
title_sort |
ndt methods suitable for evaluation the condition of military fortification construction in the field |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2020-11-01 |
description |
The protective structure is designed to protect the live force against the impact of a shock wave and projectiles, it cannot be diagnosed by the destructive method which devalues the protective structure by sampling. The authors are looking for a combination of suitable non-destructive technology (NDT) methods that would be used in the future to prove the degree of damage to cement-based protective structures after an explosion. This article represents the first part of an experiment designed to verify the applicability of NDT methods, to evaluate the degree of damage of the protective structure in the field. The experiment consists of three parts. The first part is a laboratory verification of the initial material characteristics of the materials used. The first test set of structural elements is made of steel fiber-reinforced concrete. The elements are evaluated using NDT methods and for comparison by destructive laboratory methods. The second part is the impact of structures using explosion and evaluation of the condition of structures using NDT methods in the field. The last part is used to verify the results of the NDT method, which ensures the residual strength of the structure in the laboratory and try to find the relationship between changes in the results of NDT methods and the residual strength. Radiography was included in the introductory and concluding parts of the experiment to verify the results. Although this method is not suitable for using in-situ, it is the only standardized method of the NDT methods used. |
topic |
steel fiber-reinforced concrete (SFRC) ultrasonic testing radiography electromagnetic testing NDT evaluation in situ military fortification construction |
url |
https://www.mdpi.com/2076-3417/10/22/8161 |
work_keys_str_mv |
AT zezulovaeva ndtmethodssuitableforevaluationtheconditionofmilitaryfortificationconstructioninthefield AT hasilovakamila ndtmethodssuitableforevaluationtheconditionofmilitaryfortificationconstructioninthefield AT komarkovatereza ndtmethodssuitableforevaluationtheconditionofmilitaryfortificationconstructioninthefield AT stonispatrik ndtmethodssuitableforevaluationtheconditionofmilitaryfortificationconstructioninthefield AT stollerjiri ndtmethodssuitableforevaluationtheconditionofmilitaryfortificationconstructioninthefield AT antonondrej ndtmethodssuitableforevaluationtheconditionofmilitaryfortificationconstructioninthefield |
_version_ |
1724418517244051456 |