Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortion

With the development of new energy, three-phase grid connected converter has been widely applied. In order to meet the requirement of synchronous signals extraction under the condition of asymmetry, dc components and harmonic distortion, the positive and negative sequence components, amplitude and f...

Full description

Bibliographic Details
Main Authors: Xuhu Ren, Zhengyang Lyu, Dewen Li, Zhen Zhang, Shengkun Zhang
Format: Article
Language:English
Published: Taylor & Francis Group 2018-09-01
Series:Systems Science & Control Engineering
Subjects:
Online Access:http://dx.doi.org/10.1080/21642583.2018.1554843
id doaj-eaf938d5cb6548c0a0b462312730a111
record_format Article
spelling doaj-eaf938d5cb6548c0a0b462312730a1112020-11-25T01:35:48ZengTaylor & Francis GroupSystems Science & Control Engineering2164-25832018-09-016330531310.1080/21642583.2018.15548431554843Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortionXuhu Ren0Zhengyang Lyu1Dewen Li2Zhen Zhang3Shengkun Zhang4China University of Petroleum (Eastern China)China University of Petroleum (Eastern China)China University of Petroleum (Eastern China)China University of Petroleum (Eastern China)China University of Petroleum (Eastern China)With the development of new energy, three-phase grid connected converter has been widely applied. In order to meet the requirement of synchronous signals extraction under the condition of asymmetry, dc components and harmonic distortion, the positive and negative sequence components, amplitude and fundamental frequency of the voltage signal need to be extracted accurately. Based on dual second order generalized integrator frequency locked loop (DSOGI-FLL), the synchronization signal can be extracted under voltage asymmetry and distortion. But when the three-phase voltage is asymmetrical, dc components and multiple harmonics are influenced by the DSOGI-FLL method, the synchronous signal cannot be extracted accurately. In this paper, the structure of second order generalized integrator (SOGI)is improved, and the difference node and adaptive filter are added on the basis of SOGI, and the method of synchronous signal extraction based on improved dual self-turning second order generalized integrator frequency locked loop (DSSOGI-FLL) is proposed. This method can eliminate the effect of asymmetrical, dc components and multiple harmonics, and can extract the positive and negative sequence components, phase and frequency information accurately and quickly. The accuracy and effectiveness of the improved DSSOGI-FLL method are verified by simulation analysis.http://dx.doi.org/10.1080/21642583.2018.1554843Synchronous signalpositive sequence componentfundamental frequencysecond order generalized integratorfrequency locked loop
collection DOAJ
language English
format Article
sources DOAJ
author Xuhu Ren
Zhengyang Lyu
Dewen Li
Zhen Zhang
Shengkun Zhang
spellingShingle Xuhu Ren
Zhengyang Lyu
Dewen Li
Zhen Zhang
Shengkun Zhang
Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortion
Systems Science & Control Engineering
Synchronous signal
positive sequence component
fundamental frequency
second order generalized integrator
frequency locked loop
author_facet Xuhu Ren
Zhengyang Lyu
Dewen Li
Zhen Zhang
Shengkun Zhang
author_sort Xuhu Ren
title Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortion
title_short Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortion
title_full Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortion
title_fullStr Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortion
title_full_unstemmed Synchronization signal extraction method based on enhanced DSSOGI-FLL in power grid distortion
title_sort synchronization signal extraction method based on enhanced dssogi-fll in power grid distortion
publisher Taylor & Francis Group
series Systems Science & Control Engineering
issn 2164-2583
publishDate 2018-09-01
description With the development of new energy, three-phase grid connected converter has been widely applied. In order to meet the requirement of synchronous signals extraction under the condition of asymmetry, dc components and harmonic distortion, the positive and negative sequence components, amplitude and fundamental frequency of the voltage signal need to be extracted accurately. Based on dual second order generalized integrator frequency locked loop (DSOGI-FLL), the synchronization signal can be extracted under voltage asymmetry and distortion. But when the three-phase voltage is asymmetrical, dc components and multiple harmonics are influenced by the DSOGI-FLL method, the synchronous signal cannot be extracted accurately. In this paper, the structure of second order generalized integrator (SOGI)is improved, and the difference node and adaptive filter are added on the basis of SOGI, and the method of synchronous signal extraction based on improved dual self-turning second order generalized integrator frequency locked loop (DSSOGI-FLL) is proposed. This method can eliminate the effect of asymmetrical, dc components and multiple harmonics, and can extract the positive and negative sequence components, phase and frequency information accurately and quickly. The accuracy and effectiveness of the improved DSSOGI-FLL method are verified by simulation analysis.
topic Synchronous signal
positive sequence component
fundamental frequency
second order generalized integrator
frequency locked loop
url http://dx.doi.org/10.1080/21642583.2018.1554843
work_keys_str_mv AT xuhuren synchronizationsignalextractionmethodbasedonenhanceddssogifllinpowergriddistortion
AT zhengyanglyu synchronizationsignalextractionmethodbasedonenhanceddssogifllinpowergriddistortion
AT dewenli synchronizationsignalextractionmethodbasedonenhanceddssogifllinpowergriddistortion
AT zhenzhang synchronizationsignalextractionmethodbasedonenhanceddssogifllinpowergriddistortion
AT shengkunzhang synchronizationsignalextractionmethodbasedonenhanceddssogifllinpowergriddistortion
_version_ 1725066197999812608