Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedure
Some aspects of the application of electrochemical impedance spectroscopy to studies of solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous soluti...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidade Estadual Paulista
2018-05-01
|
Series: | Eclética Química |
Online Access: | https://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/520 |
id |
doaj-ea7678379933426895b0dd4bee295a8a |
---|---|
record_format |
Article |
spelling |
doaj-ea7678379933426895b0dd4bee295a8a2020-11-25T01:38:01ZengUniversidade Estadual PaulistaEclética Química1678-46182018-05-01282294010.26850/1678-4618eqj.v28.2.2003.p29-40520Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedureA. de J. Motheo0R. M. P. Saldanha1R. de S. Neves2E. de Robertis3A. Sadkowski4Instituto de Química de São Carlos - Universidade de São Paulo – CEP 13566-590 – São Carlos SP - BrasilInstituto de Química de São Carlos - Universidade de São Paulo – CEP 13566-590 – São Carlos SP - BrasilInstituto de Química de São Carlos - Universidade de São Paulo – CEP 13566-590 – São Carlos SP - BrasilInstituto de Química de São Carlos - Universidade de São Paulo – CEP 13566-590 – São Carlos SP - BrasilInstitute of Physical Chemistry of the Polish Academy of Science - Kasprzaka 44/52 - 01-224 – Warsaw - PolandSome aspects of the application of electrochemical impedance spectroscopy to studies of solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous solution containing 10 mmol dm -3 KF, as supporting electrolyte, and a pyridine concentration varying from 0.01 to 4.6 mmol dm -3 , were used. The experimental data was analysed by using EQUIVCRT software, which utilises non-linear least squares routines, attributing to the solid electrode / solution interface behaviour described by an equivalent circuit with a resistance in series with a constant phase element. The results of this fitting procedure were analysed by the dependence on the electrode potential on two parameters: the pre-exponential factor, Y 0 , and the exponent n f , related with the phase angle shift. By this analysis it was possible to observe that the pyridine adsorption is strongly affected by the crystallographic orientation of the electrode surface and that the extent of deviation from ideal capacitive behaviour is mainly of interfacial origin.https://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/520 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A. de J. Motheo R. M. P. Saldanha R. de S. Neves E. de Robertis A. Sadkowski |
spellingShingle |
A. de J. Motheo R. M. P. Saldanha R. de S. Neves E. de Robertis A. Sadkowski Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedure Eclética Química |
author_facet |
A. de J. Motheo R. M. P. Saldanha R. de S. Neves E. de Robertis A. Sadkowski |
author_sort |
A. de J. Motheo |
title |
Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedure |
title_short |
Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedure |
title_full |
Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedure |
title_fullStr |
Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedure |
title_full_unstemmed |
Characteristics of pyridine adsorption on Au(111) and Au(210) by EIS parameters fitting procedure |
title_sort |
characteristics of pyridine adsorption on au(111) and au(210) by eis parameters fitting procedure |
publisher |
Universidade Estadual Paulista |
series |
Eclética Química |
issn |
1678-4618 |
publishDate |
2018-05-01 |
description |
Some aspects of the application of electrochemical impedance spectroscopy to studies of
solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform
this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous solution
containing 10 mmol dm -3 KF, as supporting electrolyte, and a pyridine concentration varying from 0.01
to 4.6 mmol dm -3 , were used. The experimental data was analysed by using EQUIVCRT software, which
utilises non-linear least squares routines, attributing to the solid electrode / solution interface behaviour
described by an equivalent circuit with a resistance in series with a constant phase element. The results
of this fitting procedure were analysed by the dependence on the electrode potential on two parameters:
the pre-exponential factor, Y 0 , and the exponent n f , related with the phase angle shift. By this analysis it
was possible to observe that the pyridine adsorption is strongly affected by the crystallographic orientation
of the electrode surface and that the extent of deviation from ideal capacitive behaviour is mainly of
interfacial origin. |
url |
https://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/520 |
work_keys_str_mv |
AT adejmotheo characteristicsofpyridineadsorptiononau111andau210byeisparametersfittingprocedure AT rmpsaldanha characteristicsofpyridineadsorptiononau111andau210byeisparametersfittingprocedure AT rdesneves characteristicsofpyridineadsorptiononau111andau210byeisparametersfittingprocedure AT ederobertis characteristicsofpyridineadsorptiononau111andau210byeisparametersfittingprocedure AT asadkowski characteristicsofpyridineadsorptiononau111andau210byeisparametersfittingprocedure |
_version_ |
1725055622714490880 |