Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit Breaker
The low-voltage circuit breakers are widely used to protect loads in the distribution system. Interruption reliability of circuit breakers is important because they are a protective device close to the customer. In particular, the re-ignition phenomenon leads to over-current blocking failure due to...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-12-01
|
Series: | Electronics |
Subjects: | |
Online Access: | https://www.mdpi.com/2079-9292/9/12/2148 |
id |
doaj-ea5dd1ff7fde4e82adc242e1f5c68159 |
---|---|
record_format |
Article |
spelling |
doaj-ea5dd1ff7fde4e82adc242e1f5c681592020-12-16T00:03:40ZengMDPI AGElectronics2079-92922020-12-0192148214810.3390/electronics9122148Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit BreakerYoung-Maan Cho0Kun-A Lee1Reliability Assessment Center, Hyundai Electric & Energy System Co., LTD., 17-10 Mabuk-ro, 240 bean-gil, Giheung-gu, Yongin-si 16891, Gyeonggi-do, KoreaDepartment of Electrical Engineering, DongShin University, 34-22 Dongsindae-gil, Naju-si 58245, Jeollanam-do, KoreaThe low-voltage circuit breakers are widely used to protect loads in the distribution system. Interruption reliability of circuit breakers is important because they are a protective device close to the customer. In particular, the re-ignition phenomenon leads to over-current blocking failure due to the arc re-formed between electrodes despite the normal trip of the circuit breaker. In this paper, in order to improve the interruption performance against re-ignition, the dielectric recovery voltage measurement system of the circuit breaker is used and the experiment of changing the splitter plate is carried out. Two experiments are carried out by changing the splitter plate, especially changing the material of splitter plate and the number of lower plates of the splitter plate. In the case of changing the material of the splitter plate, the analysis is conducted according to the thermal conductance. In the case of changing the number of lower plates of the splitter plate, the number of plates and their spacing are variables. Analyzing the results of the dielectric recovery voltage experiment, in the initial period, copper plates have the best value that shows 102.1% improvement compared to normal and Al shows 59.8% improvement compared to normal. These increases are related to the thermal conductivity of the three electrode materials. In the case of changing the number of lower plates of the splitter plate, the 8-plates and 9-plates show 84.5% and 36.1% increases compared to normal, respectively, in the initial period. It can be seen that too many plates interfere with heat dissipation. Since this study studies performance improvement during the initial period, there is not much difference in the later period. This is consistent with the experimental results. In this study, an experimental basis is provided for the dielectric recovery strength from a low-voltage circuit breaker. It is expected that this will contribute to the research to improve the dielectric recovery capability of the circuit breaker.https://www.mdpi.com/2079-9292/9/12/2148dielectric recovery strengthmolded case circuit breakerexperimental study |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Young-Maan Cho Kun-A Lee |
spellingShingle |
Young-Maan Cho Kun-A Lee Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit Breaker Electronics dielectric recovery strength molded case circuit breaker experimental study |
author_facet |
Young-Maan Cho Kun-A Lee |
author_sort |
Young-Maan Cho |
title |
Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit Breaker |
title_short |
Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit Breaker |
title_full |
Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit Breaker |
title_fullStr |
Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit Breaker |
title_full_unstemmed |
Experimental Study on Splitter Plate for Improving the Dielectric Recovery Strength of Low-Voltage Circuit Breaker |
title_sort |
experimental study on splitter plate for improving the dielectric recovery strength of low-voltage circuit breaker |
publisher |
MDPI AG |
series |
Electronics |
issn |
2079-9292 |
publishDate |
2020-12-01 |
description |
The low-voltage circuit breakers are widely used to protect loads in the distribution system. Interruption reliability of circuit breakers is important because they are a protective device close to the customer. In particular, the re-ignition phenomenon leads to over-current blocking failure due to the arc re-formed between electrodes despite the normal trip of the circuit breaker. In this paper, in order to improve the interruption performance against re-ignition, the dielectric recovery voltage measurement system of the circuit breaker is used and the experiment of changing the splitter plate is carried out. Two experiments are carried out by changing the splitter plate, especially changing the material of splitter plate and the number of lower plates of the splitter plate. In the case of changing the material of the splitter plate, the analysis is conducted according to the thermal conductance. In the case of changing the number of lower plates of the splitter plate, the number of plates and their spacing are variables. Analyzing the results of the dielectric recovery voltage experiment, in the initial period, copper plates have the best value that shows 102.1% improvement compared to normal and Al shows 59.8% improvement compared to normal. These increases are related to the thermal conductivity of the three electrode materials. In the case of changing the number of lower plates of the splitter plate, the 8-plates and 9-plates show 84.5% and 36.1% increases compared to normal, respectively, in the initial period. It can be seen that too many plates interfere with heat dissipation. Since this study studies performance improvement during the initial period, there is not much difference in the later period. This is consistent with the experimental results. In this study, an experimental basis is provided for the dielectric recovery strength from a low-voltage circuit breaker. It is expected that this will contribute to the research to improve the dielectric recovery capability of the circuit breaker. |
topic |
dielectric recovery strength molded case circuit breaker experimental study |
url |
https://www.mdpi.com/2079-9292/9/12/2148 |
work_keys_str_mv |
AT youngmaancho experimentalstudyonsplitterplateforimprovingthedielectricrecoverystrengthoflowvoltagecircuitbreaker AT kunalee experimentalstudyonsplitterplateforimprovingthedielectricrecoverystrengthoflowvoltagecircuitbreaker |
_version_ |
1724381929063579648 |