RADON-222 DETECTION USING BETA-DECAY PRODUCTS
The paper shows the possibility of determining of the radon by the radiometer on a base of multi-channel time analyzer of beta – decay products of radon. The radiometer consist of an electrostatic aerosol collector combined with the air intake, Geiger-Muller counter for detection of beta particles a...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
V.N. Karazin Kharkiv National University Publishing
2016-08-01
|
Series: | East European Journal of Physics |
Subjects: | |
Online Access: | https://periodicals.karazin.ua/eejp/article/view/6192 |
id |
doaj-ea07443f499543ffadad5e67676ad02a |
---|---|
record_format |
Article |
spelling |
doaj-ea07443f499543ffadad5e67676ad02a2020-11-24T22:01:23ZengV.N. Karazin Kharkiv National University PublishingEast European Journal of Physics2312-43342312-45392016-08-013265696192RADON-222 DETECTION USING BETA-DECAY PRODUCTSI. I. Yakimenko0N. G. Styervoyedov1A. F. Shchus2G. M. Onyshchenko3V.N. Karazin Kharkiv National University Svobody Sq. 4, 61022, Kharkiv, UkrainеV.N. Karazin Kharkiv National University Svobody Sq. 4, 61022, Kharkiv, UkrainеV.N. Karazin Kharkiv National University Svobody Sq. 4, 61022, Kharkiv, UkrainеV.N. Karazin Kharkiv National University Svobody Sq. 4, 61022, Kharkiv, UkrainеThe paper shows the possibility of determining of the radon by the radiometer on a base of multi-channel time analyzer of beta – decay products of radon. The radiometer consist of an electrostatic aerosol collector combined with the air intake, Geiger-Muller counter for detection of beta particles and multi-channel time analyzer. Accumulation time of aerosol sample takes up to 20 min, the time data processing is done by the radiometer about 5 hours. The data processing is at off-line mode using the computer decomposition process of decay spectrum.https://periodicals.karazin.ua/eejp/article/view/6192beta activityradiometerRadon-222multi-channel time analyzer |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
I. I. Yakimenko N. G. Styervoyedov A. F. Shchus G. M. Onyshchenko |
spellingShingle |
I. I. Yakimenko N. G. Styervoyedov A. F. Shchus G. M. Onyshchenko RADON-222 DETECTION USING BETA-DECAY PRODUCTS East European Journal of Physics beta activity radiometer Radon-222 multi-channel time analyzer |
author_facet |
I. I. Yakimenko N. G. Styervoyedov A. F. Shchus G. M. Onyshchenko |
author_sort |
I. I. Yakimenko |
title |
RADON-222 DETECTION USING BETA-DECAY PRODUCTS |
title_short |
RADON-222 DETECTION USING BETA-DECAY PRODUCTS |
title_full |
RADON-222 DETECTION USING BETA-DECAY PRODUCTS |
title_fullStr |
RADON-222 DETECTION USING BETA-DECAY PRODUCTS |
title_full_unstemmed |
RADON-222 DETECTION USING BETA-DECAY PRODUCTS |
title_sort |
radon-222 detection using beta-decay products |
publisher |
V.N. Karazin Kharkiv National University Publishing |
series |
East European Journal of Physics |
issn |
2312-4334 2312-4539 |
publishDate |
2016-08-01 |
description |
The paper shows the possibility of determining of the radon by the radiometer on a base of multi-channel time analyzer of beta – decay products of radon. The radiometer consist of an electrostatic aerosol collector combined with the air intake, Geiger-Muller counter for detection of beta particles and multi-channel time analyzer. Accumulation time of aerosol sample takes up to 20 min, the time data processing is done by the radiometer about 5 hours. The data processing is at off-line mode using the computer decomposition process of decay spectrum. |
topic |
beta activity radiometer Radon-222 multi-channel time analyzer |
url |
https://periodicals.karazin.ua/eejp/article/view/6192 |
work_keys_str_mv |
AT iiyakimenko radon222detectionusingbetadecayproducts AT ngstyervoyedov radon222detectionusingbetadecayproducts AT afshchus radon222detectionusingbetadecayproducts AT gmonyshchenko radon222detectionusingbetadecayproducts |
_version_ |
1725839967778766848 |