Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac Arrest

Background: Implantable Cardioverter-defibrillators (ICD) reduce mortality in survivors of cardiac arrest (CA). We investigated the predictors of mortality after ICD implantation in survivors of CA. Methods: Retrospective review of clinical records and social security death index of all patients wh...

Full description

Bibliographic Details
Main Authors: Sunil K. Agarwal, Ish Singla, Haitham Hreybe, Samir Saba
Format: Article
Language:English
Published: Elsevier 2007-10-01
Series:Indian Pacing and Electrophysiology Journal
Subjects:
Online Access:http://www.ipej.org/0704/saba2.htm
id doaj-e9f3a4ca3622456fb759553697cc1d4c
record_format Article
spelling doaj-e9f3a4ca3622456fb759553697cc1d4c2020-11-24T23:36:36ZengElsevierIndian Pacing and Electrophysiology Journal0972-62922007-10-0174218224Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac ArrestSunil K. AgarwalIsh SinglaHaitham HreybeSamir SabaBackground: Implantable Cardioverter-defibrillators (ICD) reduce mortality in survivors of cardiac arrest (CA). We investigated the predictors of mortality after ICD implantation in survivors of CA. Methods: Retrospective review of clinical records and social security death index of all patients who received an ICD in a preexisting database of survivors of CA at the University of Pittsburgh Medical Center was performed. Multivariate analyses using the Cox proportional hazard model were performed with backward elimination to identify independent predictors of the time to death, and Kaplan-Meier curves were plotted.Results: Eighty patients (64 men) with a mean age of 64.4±12.5 years were followed for 4.7±2.3 years after ICD implantation. Survival rates were 93.8%, 65% and 50% at 1, 5, and 10 years, respectively. Independent predictors of time to death were determined to include age (hazard ratio (HR) = 1.91 per 10-year increase, p = 0.003), serum creatinine ≥ 1.3 mg/dL (HR = 2.56, p = 0.004), and QRS width >120 ms (HR = 5.14, p = 0.012). Conclusions: In this sample of ICD recipients secondary to CA, older age, elevated serum creatinine, and wider QRS duration were independent predictors of mortality. The presence of more than one risk factor in the same patient was associated with higher mortality rates. Whether interventions such as biventricular pacing can offset this increase risk of death warrants further investigation.http://www.ipej.org/0704/saba2.htmImplantable Cardioverter DefibrillatorsCardiac ArrestMortalityPredictors
collection DOAJ
language English
format Article
sources DOAJ
author Sunil K. Agarwal
Ish Singla
Haitham Hreybe
Samir Saba
spellingShingle Sunil K. Agarwal
Ish Singla
Haitham Hreybe
Samir Saba
Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac Arrest
Indian Pacing and Electrophysiology Journal
Implantable Cardioverter Defibrillators
Cardiac Arrest
Mortality
Predictors
author_facet Sunil K. Agarwal
Ish Singla
Haitham Hreybe
Samir Saba
author_sort Sunil K. Agarwal
title Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac Arrest
title_short Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac Arrest
title_full Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac Arrest
title_fullStr Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac Arrest
title_full_unstemmed Predictors of Mortality Amongst Recipients of Implantable Cardioverter Defibrillators for Secondary Prevention of Cardiac Arrest
title_sort predictors of mortality amongst recipients of implantable cardioverter defibrillators for secondary prevention of cardiac arrest
publisher Elsevier
series Indian Pacing and Electrophysiology Journal
issn 0972-6292
publishDate 2007-10-01
description Background: Implantable Cardioverter-defibrillators (ICD) reduce mortality in survivors of cardiac arrest (CA). We investigated the predictors of mortality after ICD implantation in survivors of CA. Methods: Retrospective review of clinical records and social security death index of all patients who received an ICD in a preexisting database of survivors of CA at the University of Pittsburgh Medical Center was performed. Multivariate analyses using the Cox proportional hazard model were performed with backward elimination to identify independent predictors of the time to death, and Kaplan-Meier curves were plotted.Results: Eighty patients (64 men) with a mean age of 64.4±12.5 years were followed for 4.7±2.3 years after ICD implantation. Survival rates were 93.8%, 65% and 50% at 1, 5, and 10 years, respectively. Independent predictors of time to death were determined to include age (hazard ratio (HR) = 1.91 per 10-year increase, p = 0.003), serum creatinine ≥ 1.3 mg/dL (HR = 2.56, p = 0.004), and QRS width >120 ms (HR = 5.14, p = 0.012). Conclusions: In this sample of ICD recipients secondary to CA, older age, elevated serum creatinine, and wider QRS duration were independent predictors of mortality. The presence of more than one risk factor in the same patient was associated with higher mortality rates. Whether interventions such as biventricular pacing can offset this increase risk of death warrants further investigation.
topic Implantable Cardioverter Defibrillators
Cardiac Arrest
Mortality
Predictors
url http://www.ipej.org/0704/saba2.htm
work_keys_str_mv AT sunilkagarwal predictorsofmortalityamongstrecipientsofimplantablecardioverterdefibrillatorsforsecondarypreventionofcardiacarrest
AT ishsingla predictorsofmortalityamongstrecipientsofimplantablecardioverterdefibrillatorsforsecondarypreventionofcardiacarrest
AT haithamhreybe predictorsofmortalityamongstrecipientsofimplantablecardioverterdefibrillatorsforsecondarypreventionofcardiacarrest
AT samirsaba predictorsofmortalityamongstrecipientsofimplantablecardioverterdefibrillatorsforsecondarypreventionofcardiacarrest
_version_ 1725522537568272384