MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced Condition

Unbalanced input source voltages generate extra current harmonics in addition to non-linear loads which distorts the power quality in the entire power systems. Three-phase multi-level neutral point clamped (NPC) converter based shunt active harmonic filter (SAHF) are used as a solution to overcome p...

Full description

Bibliographic Details
Main Authors: Haider Muhamad Husen, Salar Ahmed Qadir
Format: Article
Language:English
Published: Sulaimani Polytechnic University 2020-06-01
Series:Kurdistan Journal of Applied Research
Subjects:
Online Access:http://www.kjar.spu.edu.iq/index.php/kjar/article/view/463
id doaj-e98bb77bc3ec45aa94aa6dd0d624fb5e
record_format Article
spelling doaj-e98bb77bc3ec45aa94aa6dd0d624fb5e2020-11-25T03:48:38ZengSulaimani Polytechnic UniversityKurdistan Journal of Applied Research2411-76842411-77062020-06-015114916310.24017/science.2020.1.8463MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced ConditionHaider Muhamad Husen0Salar Ahmed Qadir1Electrical Department, Kalar Technical Institute, Sulaimani Polytechnic University, Kalar, IraqElectrical Department, Kalar Technical Institute, Sulaimani Polytechnic University, Kalar, IraqUnbalanced input source voltages generate extra current harmonics in addition to non-linear loads which distorts the power quality in the entire power systems. Three-phase multi-level neutral point clamped (NPC) converter based shunt active harmonic filter (SAHF) are used as a solution to overcome problems due to current harmonics. In this work, synchronous reference frame (d-q) algorithm is selected to detect the harmonic current components, Proportional-integral (PI) controller is utilized to ameliorate the storage of energy in the dc-link capacitor and the multilevel space vector pulse width modulation (MSVPWM) strategy determines the switching pulses of NPC inverter. Under balanced input supply voltages condition, the proposed MSVPWM achieved a mitigation of source current THD of 3.58 % as compared to 28.57 % prior to compensation on non-linear load. Furthermore, the MSVPWM technique was compared with and without compensation under unbalanced input source voltages and the results shows that the proposed method achieved reduction in source current THD of 3.96 % as compared to 29.76 % after and before compensation respectively. The proposed MSVPWM based-SAPF model was also compared with conventional SVPWM under balanced and unbalanced input supply voltages conditions. The results show that MSVPWM performed better than CSVPWM. The simulated results obtained by MATLAB/SIMULINK power system environment. All the results for the presented work are within IEEE-519 harmonics standard with non-linear loads under balanced and unbalanced voltages condition.http://www.kjar.spu.edu.iq/index.php/kjar/article/view/463harmonics, dq-theory, multilevel inverter (mli), diode clamping inverter, csvpwm, sahf.
collection DOAJ
language English
format Article
sources DOAJ
author Haider Muhamad Husen
Salar Ahmed Qadir
spellingShingle Haider Muhamad Husen
Salar Ahmed Qadir
MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced Condition
Kurdistan Journal of Applied Research
harmonics, dq-theory, multilevel inverter (mli), diode clamping inverter, csvpwm, sahf.
author_facet Haider Muhamad Husen
Salar Ahmed Qadir
author_sort Haider Muhamad Husen
title MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced Condition
title_short MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced Condition
title_full MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced Condition
title_fullStr MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced Condition
title_full_unstemmed MSVPWM Based-SAPF For Harmonic Mitigation in The Distribution Network Under Unbalanced Condition
title_sort msvpwm based-sapf for harmonic mitigation in the distribution network under unbalanced condition
publisher Sulaimani Polytechnic University
series Kurdistan Journal of Applied Research
issn 2411-7684
2411-7706
publishDate 2020-06-01
description Unbalanced input source voltages generate extra current harmonics in addition to non-linear loads which distorts the power quality in the entire power systems. Three-phase multi-level neutral point clamped (NPC) converter based shunt active harmonic filter (SAHF) are used as a solution to overcome problems due to current harmonics. In this work, synchronous reference frame (d-q) algorithm is selected to detect the harmonic current components, Proportional-integral (PI) controller is utilized to ameliorate the storage of energy in the dc-link capacitor and the multilevel space vector pulse width modulation (MSVPWM) strategy determines the switching pulses of NPC inverter. Under balanced input supply voltages condition, the proposed MSVPWM achieved a mitigation of source current THD of 3.58 % as compared to 28.57 % prior to compensation on non-linear load. Furthermore, the MSVPWM technique was compared with and without compensation under unbalanced input source voltages and the results shows that the proposed method achieved reduction in source current THD of 3.96 % as compared to 29.76 % after and before compensation respectively. The proposed MSVPWM based-SAPF model was also compared with conventional SVPWM under balanced and unbalanced input supply voltages conditions. The results show that MSVPWM performed better than CSVPWM. The simulated results obtained by MATLAB/SIMULINK power system environment. All the results for the presented work are within IEEE-519 harmonics standard with non-linear loads under balanced and unbalanced voltages condition.
topic harmonics, dq-theory, multilevel inverter (mli), diode clamping inverter, csvpwm, sahf.
url http://www.kjar.spu.edu.iq/index.php/kjar/article/view/463
work_keys_str_mv AT haidermuhamadhusen msvpwmbasedsapfforharmonicmitigationinthedistributionnetworkunderunbalancedcondition
AT salarahmedqadir msvpwmbasedsapfforharmonicmitigationinthedistributionnetworkunderunbalancedcondition
_version_ 1724497861777817600