SSR Analysis of DFIG-Based Wind Farm With VSM Control Strategy

The wind turbine is usually integrated into the power grid via back to back converter, and the inertia is decreased. Virtual synchronous machine (VSM) control was proposed to improve inertia of the wind farm. While for the doubly-fed induction generator (DFIG)-based wind farm with traditional contro...

Full description

Bibliographic Details
Main Authors: Kanghui Gu, Feng Wu, Xiao-Ping Zhang, Ping Ju, Haiqiang Zhou, Jiajie Luo, Jianing Li
Format: Article
Language:English
Published: IEEE 2019-01-01
Series:IEEE Access
Subjects:
SSR
VSM
Online Access:https://ieeexplore.ieee.org/document/8809702/
id doaj-e974f9b5ca7d42cc92b18a764bb125a1
record_format Article
spelling doaj-e974f9b5ca7d42cc92b18a764bb125a12021-03-30T00:01:11ZengIEEEIEEE Access2169-35362019-01-01711870211871110.1109/ACCESS.2019.29368728809702SSR Analysis of DFIG-Based Wind Farm With VSM Control StrategyKanghui Gu0https://orcid.org/0000-0002-8709-7962Feng Wu1Xiao-Ping Zhang2https://orcid.org/0000-0003-0995-4989Ping Ju3https://orcid.org/0000-0002-9827-1241Haiqiang Zhou4Jiajie Luo5Jianing Li6College of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaDepartment of Electronic, Electrical and System Engineering, University of Birmingham, Birmingham, U.K.College of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaCollege of Energy and Electrical Engineering, Hohai University, Nanjing, ChinaDepartment of Electronic, Electrical and System Engineering, University of Birmingham, Birmingham, U.K.Department of Electronic, Electrical and System Engineering, University of Birmingham, Birmingham, U.K.The wind turbine is usually integrated into the power grid via back to back converter, and the inertia is decreased. Virtual synchronous machine (VSM) control was proposed to improve inertia of the wind farm. While for the doubly-fed induction generator (DFIG)-based wind farm with traditional control strategy, sub-synchronous resonance (SSR) has become a significant problem when it is connected to series compensation transmission lines. Therefore, the impacts of VSM control strategy for DFIG on SSR need to be investigated. In this paper, a detailed small-signal stability analysis model of the VSM control strategy is first established and eigenvalue analysis is then carried out. SSR in the wind farm with the VSM control under different series compensation levels, controller parameters and wind speeds is analyzed, and it is also compared to that in the wind farm with the conventional vector control strategy (VC). Simulations are performed in PSCAD/EMTDC to verify the result of SSR analysis.https://ieeexplore.ieee.org/document/8809702/SSRVSMeigenvalue analysiswind power plant
collection DOAJ
language English
format Article
sources DOAJ
author Kanghui Gu
Feng Wu
Xiao-Ping Zhang
Ping Ju
Haiqiang Zhou
Jiajie Luo
Jianing Li
spellingShingle Kanghui Gu
Feng Wu
Xiao-Ping Zhang
Ping Ju
Haiqiang Zhou
Jiajie Luo
Jianing Li
SSR Analysis of DFIG-Based Wind Farm With VSM Control Strategy
IEEE Access
SSR
VSM
eigenvalue analysis
wind power plant
author_facet Kanghui Gu
Feng Wu
Xiao-Ping Zhang
Ping Ju
Haiqiang Zhou
Jiajie Luo
Jianing Li
author_sort Kanghui Gu
title SSR Analysis of DFIG-Based Wind Farm With VSM Control Strategy
title_short SSR Analysis of DFIG-Based Wind Farm With VSM Control Strategy
title_full SSR Analysis of DFIG-Based Wind Farm With VSM Control Strategy
title_fullStr SSR Analysis of DFIG-Based Wind Farm With VSM Control Strategy
title_full_unstemmed SSR Analysis of DFIG-Based Wind Farm With VSM Control Strategy
title_sort ssr analysis of dfig-based wind farm with vsm control strategy
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2019-01-01
description The wind turbine is usually integrated into the power grid via back to back converter, and the inertia is decreased. Virtual synchronous machine (VSM) control was proposed to improve inertia of the wind farm. While for the doubly-fed induction generator (DFIG)-based wind farm with traditional control strategy, sub-synchronous resonance (SSR) has become a significant problem when it is connected to series compensation transmission lines. Therefore, the impacts of VSM control strategy for DFIG on SSR need to be investigated. In this paper, a detailed small-signal stability analysis model of the VSM control strategy is first established and eigenvalue analysis is then carried out. SSR in the wind farm with the VSM control under different series compensation levels, controller parameters and wind speeds is analyzed, and it is also compared to that in the wind farm with the conventional vector control strategy (VC). Simulations are performed in PSCAD/EMTDC to verify the result of SSR analysis.
topic SSR
VSM
eigenvalue analysis
wind power plant
url https://ieeexplore.ieee.org/document/8809702/
work_keys_str_mv AT kanghuigu ssranalysisofdfigbasedwindfarmwithvsmcontrolstrategy
AT fengwu ssranalysisofdfigbasedwindfarmwithvsmcontrolstrategy
AT xiaopingzhang ssranalysisofdfigbasedwindfarmwithvsmcontrolstrategy
AT pingju ssranalysisofdfigbasedwindfarmwithvsmcontrolstrategy
AT haiqiangzhou ssranalysisofdfigbasedwindfarmwithvsmcontrolstrategy
AT jiajieluo ssranalysisofdfigbasedwindfarmwithvsmcontrolstrategy
AT jianingli ssranalysisofdfigbasedwindfarmwithvsmcontrolstrategy
_version_ 1724188824130551808