Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study

Abstract Background Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of...

Full description

Bibliographic Details
Main Authors: Jacobo Rodríguez-Sanz, Carlos López-de-Celis, César Hidalgo-García, Max Canet-Vintró, Pablo Fanlo-Mazas, Albert Pérez-Bellmunt
Format: Article
Language:English
Published: BMC 2021-02-01
Series:BMC Musculoskeletal Disorders
Subjects:
Online Access:https://doi.org/10.1186/s12891-020-03918-7
id doaj-e8e93537e1f346afb7c7eff6926942b1
record_format Article
spelling doaj-e8e93537e1f346afb7c7eff6926942b12021-02-07T12:18:52ZengBMCBMC Musculoskeletal Disorders1471-24742021-02-012211810.1186/s12891-020-03918-7Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric studyJacobo Rodríguez-Sanz0Carlos López-de-Celis1César Hidalgo-García2Max Canet-Vintró3Pablo Fanlo-Mazas4Albert Pérez-Bellmunt5Universitat Internacional de Catalunya. Actium functional anatomy group. Faculty of Medicine and Health SciencesUniversitat Internacional de Catalunya. Actium functional anatomy group. Faculty of Medicine and Health SciencesFacultad de Ciencias de la Salud de la Universidad de Zaragoza, Unidad de Investigación en FisioterapiaUniversitat Internacional de Catalunya. Actium functional anatomy group. Faculty of Medicine and Health SciencesFacultad de Ciencias de la Salud de la Universidad de Zaragoza, Unidad de Investigación en FisioterapiaUniversitat Internacional de Catalunya. Actium functional anatomy group. Faculty of Medicine and Health SciencesAbstract Background Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of temperature and current flow in the shoulder tissues during two different areas of application of the movable capacitive-resistive electric transfer electrode. Methods A cross-sectional study designed, five fresh cryopreserved cadavers (10 shoulders) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) were performed for 5 min each by a diathermy “T-Plus” device in two shoulder regions: postero-superior and antero-lateral. Supraspinatus tendon, glenohumeral capsule and superficial temperatures were recorded at 1-min intervals and 5 min after treatment. Results A statistically significant difference was found only for the superficial area and time interaction, with high power-resistive application at the postero-superior shoulder area (P< 0.035). All the applications showed a 5 min after treatment temperature increase compared with the basal data, in all the application points. Superficial temperature in the high power-resistive application showed the greatest percent increase (42.93% ± 22.58), followed by the temperature in the tendon area with the same high power-resistive application (22.97% ± 14.70). The high power-resistive application showed the greatest percent of temperature increase in the applications, reaching 65.9% ± 22.96 at 5-min at the superficial level, and 32% ± 24.25 at 4-min at the level of the supraspinatus tendon. At the capsule level, high power-resistive was also the application that showed the greatest percent of increase, with 21.52% ± 16.16. The application with the lowest percent of temperature increase was the low power-capacitive, with a mean value of 4.86% at supraspinatus tendon level and 7.47% at capsular level. Conclusion The shoulder postero-superior or antero-lateral areas of application of capacitive-resistive electric transfer did not cause statistically significant differences in the temperature changes in either supraspinatus tendon or glenohumeral capsule tissues in cadaveric samples. The high power-resistive application in the postero-superior area significantly increased superficial temperature compared with the same application in the antero-lateral position area.https://doi.org/10.1186/s12891-020-03918-7Supraspinatus tendonCadaverCRetShoulderGlenohumeral capsulePhysical therapy
collection DOAJ
language English
format Article
sources DOAJ
author Jacobo Rodríguez-Sanz
Carlos López-de-Celis
César Hidalgo-García
Max Canet-Vintró
Pablo Fanlo-Mazas
Albert Pérez-Bellmunt
spellingShingle Jacobo Rodríguez-Sanz
Carlos López-de-Celis
César Hidalgo-García
Max Canet-Vintró
Pablo Fanlo-Mazas
Albert Pérez-Bellmunt
Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
BMC Musculoskeletal Disorders
Supraspinatus tendon
Cadaver
CRet
Shoulder
Glenohumeral capsule
Physical therapy
author_facet Jacobo Rodríguez-Sanz
Carlos López-de-Celis
César Hidalgo-García
Max Canet-Vintró
Pablo Fanlo-Mazas
Albert Pérez-Bellmunt
author_sort Jacobo Rodríguez-Sanz
title Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
title_short Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
title_full Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
title_fullStr Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
title_full_unstemmed Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
title_sort temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
publisher BMC
series BMC Musculoskeletal Disorders
issn 1471-2474
publishDate 2021-02-01
description Abstract Background Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of temperature and current flow in the shoulder tissues during two different areas of application of the movable capacitive-resistive electric transfer electrode. Methods A cross-sectional study designed, five fresh cryopreserved cadavers (10 shoulders) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) were performed for 5 min each by a diathermy “T-Plus” device in two shoulder regions: postero-superior and antero-lateral. Supraspinatus tendon, glenohumeral capsule and superficial temperatures were recorded at 1-min intervals and 5 min after treatment. Results A statistically significant difference was found only for the superficial area and time interaction, with high power-resistive application at the postero-superior shoulder area (P< 0.035). All the applications showed a 5 min after treatment temperature increase compared with the basal data, in all the application points. Superficial temperature in the high power-resistive application showed the greatest percent increase (42.93% ± 22.58), followed by the temperature in the tendon area with the same high power-resistive application (22.97% ± 14.70). The high power-resistive application showed the greatest percent of temperature increase in the applications, reaching 65.9% ± 22.96 at 5-min at the superficial level, and 32% ± 24.25 at 4-min at the level of the supraspinatus tendon. At the capsule level, high power-resistive was also the application that showed the greatest percent of increase, with 21.52% ± 16.16. The application with the lowest percent of temperature increase was the low power-capacitive, with a mean value of 4.86% at supraspinatus tendon level and 7.47% at capsular level. Conclusion The shoulder postero-superior or antero-lateral areas of application of capacitive-resistive electric transfer did not cause statistically significant differences in the temperature changes in either supraspinatus tendon or glenohumeral capsule tissues in cadaveric samples. The high power-resistive application in the postero-superior area significantly increased superficial temperature compared with the same application in the antero-lateral position area.
topic Supraspinatus tendon
Cadaver
CRet
Shoulder
Glenohumeral capsule
Physical therapy
url https://doi.org/10.1186/s12891-020-03918-7
work_keys_str_mv AT jacoborodriguezsanz temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy
AT carloslopezdecelis temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy
AT cesarhidalgogarcia temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy
AT maxcanetvintro temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy
AT pablofanlomazas temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy
AT albertperezbellmunt temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy
_version_ 1724281383490158592