Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements

The application of hydrodynamically closed capillary zone electrophoresis combined with convenient ultraviolet (UV) detection allows fast, simple, environmentally friendly and cost-effective analysis of ions or ionisable molecules. This technique has been used to determine two selected B vitamins (t...

Full description

Bibliographic Details
Main Authors: Matuskova M., Cizmarova I., Chalova P., Mikus P., Piestansky J.
Format: Article
Language:English
Published: Sciendo 2021-07-01
Series:European Pharmaceutical Journal
Subjects:
Online Access:https://doi.org/10.2478/afpuc-2021-0002
id doaj-e88d76fecf024fd1a385b08e96a35ff1
record_format Article
spelling doaj-e88d76fecf024fd1a385b08e96a35ff12021-10-03T07:42:44ZengSciendoEuropean Pharmaceutical Journal2453-67252021-07-01681596210.2478/afpuc-2021-0002Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplementsMatuskova M.0Cizmarova I.1Chalova P.2Mikus P.3Piestansky J.4Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicThe application of hydrodynamically closed capillary zone electrophoresis combined with convenient ultraviolet (UV) detection allows fast, simple, environmentally friendly and cost-effective analysis of ions or ionisable molecules. This technique has been used to determine two selected B vitamins (thiamine, pyridoxine) in various drug formulations. The developed method was characterised by excellent validation parameters, such as linearity, precision, accuracy, limit of detection and limit of quantification. The total time of analysis was lower than 13.5 min. The results indicate that the method is suitable for implementation in routine quality control of selected B vitamins in pharmaceutical and food samples.https://doi.org/10.2478/afpuc-2021-0002capillary zone electrophoresishydrodynamically closed systemultraviolet detectionthiaminepyridoxinequality control
collection DOAJ
language English
format Article
sources DOAJ
author Matuskova M.
Cizmarova I.
Chalova P.
Mikus P.
Piestansky J.
spellingShingle Matuskova M.
Cizmarova I.
Chalova P.
Mikus P.
Piestansky J.
Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements
European Pharmaceutical Journal
capillary zone electrophoresis
hydrodynamically closed system
ultraviolet detection
thiamine
pyridoxine
quality control
author_facet Matuskova M.
Cizmarova I.
Chalova P.
Mikus P.
Piestansky J.
author_sort Matuskova M.
title Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements
title_short Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements
title_full Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements
title_fullStr Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements
title_full_unstemmed Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements
title_sort rapid and simple cze-uv method for quality control of b1 and b6 vitamins in drugs and dietary supplements
publisher Sciendo
series European Pharmaceutical Journal
issn 2453-6725
publishDate 2021-07-01
description The application of hydrodynamically closed capillary zone electrophoresis combined with convenient ultraviolet (UV) detection allows fast, simple, environmentally friendly and cost-effective analysis of ions or ionisable molecules. This technique has been used to determine two selected B vitamins (thiamine, pyridoxine) in various drug formulations. The developed method was characterised by excellent validation parameters, such as linearity, precision, accuracy, limit of detection and limit of quantification. The total time of analysis was lower than 13.5 min. The results indicate that the method is suitable for implementation in routine quality control of selected B vitamins in pharmaceutical and food samples.
topic capillary zone electrophoresis
hydrodynamically closed system
ultraviolet detection
thiamine
pyridoxine
quality control
url https://doi.org/10.2478/afpuc-2021-0002
work_keys_str_mv AT matuskovam rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements
AT cizmarovai rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements
AT chalovap rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements
AT mikusp rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements
AT piestanskyj rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements
_version_ 1716845844644233216