Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements
The application of hydrodynamically closed capillary zone electrophoresis combined with convenient ultraviolet (UV) detection allows fast, simple, environmentally friendly and cost-effective analysis of ions or ionisable molecules. This technique has been used to determine two selected B vitamins (t...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sciendo
2021-07-01
|
Series: | European Pharmaceutical Journal |
Subjects: | |
Online Access: | https://doi.org/10.2478/afpuc-2021-0002 |
id |
doaj-e88d76fecf024fd1a385b08e96a35ff1 |
---|---|
record_format |
Article |
spelling |
doaj-e88d76fecf024fd1a385b08e96a35ff12021-10-03T07:42:44ZengSciendoEuropean Pharmaceutical Journal2453-67252021-07-01681596210.2478/afpuc-2021-0002Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplementsMatuskova M.0Cizmarova I.1Chalova P.2Mikus P.3Piestansky J.4Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicDepartment of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojárov 10, SK-832 32Bratislava, Slovak RepublicThe application of hydrodynamically closed capillary zone electrophoresis combined with convenient ultraviolet (UV) detection allows fast, simple, environmentally friendly and cost-effective analysis of ions or ionisable molecules. This technique has been used to determine two selected B vitamins (thiamine, pyridoxine) in various drug formulations. The developed method was characterised by excellent validation parameters, such as linearity, precision, accuracy, limit of detection and limit of quantification. The total time of analysis was lower than 13.5 min. The results indicate that the method is suitable for implementation in routine quality control of selected B vitamins in pharmaceutical and food samples.https://doi.org/10.2478/afpuc-2021-0002capillary zone electrophoresishydrodynamically closed systemultraviolet detectionthiaminepyridoxinequality control |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Matuskova M. Cizmarova I. Chalova P. Mikus P. Piestansky J. |
spellingShingle |
Matuskova M. Cizmarova I. Chalova P. Mikus P. Piestansky J. Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements European Pharmaceutical Journal capillary zone electrophoresis hydrodynamically closed system ultraviolet detection thiamine pyridoxine quality control |
author_facet |
Matuskova M. Cizmarova I. Chalova P. Mikus P. Piestansky J. |
author_sort |
Matuskova M. |
title |
Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements |
title_short |
Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements |
title_full |
Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements |
title_fullStr |
Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements |
title_full_unstemmed |
Rapid and simple CZE-UV method for quality control of B1 and B6 vitamins in drugs and dietary supplements |
title_sort |
rapid and simple cze-uv method for quality control of b1 and b6 vitamins in drugs and dietary supplements |
publisher |
Sciendo |
series |
European Pharmaceutical Journal |
issn |
2453-6725 |
publishDate |
2021-07-01 |
description |
The application of hydrodynamically closed capillary zone electrophoresis combined with convenient ultraviolet (UV) detection allows fast, simple, environmentally friendly and cost-effective analysis of ions or ionisable molecules. This technique has been used to determine two selected B vitamins (thiamine, pyridoxine) in various drug formulations. The developed method was characterised by excellent validation parameters, such as linearity, precision, accuracy, limit of detection and limit of quantification. The total time of analysis was lower than 13.5 min. The results indicate that the method is suitable for implementation in routine quality control of selected B vitamins in pharmaceutical and food samples. |
topic |
capillary zone electrophoresis hydrodynamically closed system ultraviolet detection thiamine pyridoxine quality control |
url |
https://doi.org/10.2478/afpuc-2021-0002 |
work_keys_str_mv |
AT matuskovam rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements AT cizmarovai rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements AT chalovap rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements AT mikusp rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements AT piestanskyj rapidandsimpleczeuvmethodforqualitycontrolofb1andb6vitaminsindrugsanddietarysupplements |
_version_ |
1716845844644233216 |