iStent trabecular micro-bypass stent for open-angle glaucoma

Kim Le, Hady Saheb Department of Ophthalmology, McGill University, Montreal, QC, Canada Abstract: Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outf...

Full description

Bibliographic Details
Main Authors: Le K, Saheb H
Format: Article
Language:English
Published: Dove Medical Press 2014-09-01
Series:Clinical Ophthalmology
Online Access:http://www.dovepress.com/istent-trabecular-micro-bypass-stent-for-open-angle-glaucoma-peer-reviewed-article-OPTH
id doaj-e7c62e33d73d4192b2a56bfcedf3c825
record_format Article
spelling doaj-e7c62e33d73d4192b2a56bfcedf3c8252020-11-25T01:48:47ZengDove Medical PressClinical Ophthalmology1177-54832014-09-012014default1937194518467iStent trabecular micro-bypass stent for open-angle glaucomaLe KSaheb H Kim Le, Hady Saheb Department of Ophthalmology, McGill University, Montreal, QC, Canada Abstract: Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm’s canal. iStents are typically implanted at the time of phacoemulsification for patients with open-angle glaucoma and visually significant cataracts. This review summarizes the published data regarding the efficacy, safety, and cost considerations of trabecular micro-bypass stents. Most studies found statistically significant reductions in mean IOP and ocular medication use after combined phacoemulsification with single or double iStent implantation. The devices were found to be very safe, with a safety profile similar to that of cataract surgery. Complications were infrequent, with the most common complications being temporary stent obstruction or malposition, which resolved with observation or secondary procedures. Future studies are needed to evaluate long-term outcomes, patient satisfaction, cost effectiveness, and expanded indications. Keywords: iStent, trabecular micro-bypass, glaucoma, MIGS, ab interno, surgeryhttp://www.dovepress.com/istent-trabecular-micro-bypass-stent-for-open-angle-glaucoma-peer-reviewed-article-OPTH
collection DOAJ
language English
format Article
sources DOAJ
author Le K
Saheb H
spellingShingle Le K
Saheb H
iStent trabecular micro-bypass stent for open-angle glaucoma
Clinical Ophthalmology
author_facet Le K
Saheb H
author_sort Le K
title iStent trabecular micro-bypass stent for open-angle glaucoma
title_short iStent trabecular micro-bypass stent for open-angle glaucoma
title_full iStent trabecular micro-bypass stent for open-angle glaucoma
title_fullStr iStent trabecular micro-bypass stent for open-angle glaucoma
title_full_unstemmed iStent trabecular micro-bypass stent for open-angle glaucoma
title_sort istent trabecular micro-bypass stent for open-angle glaucoma
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2014-09-01
description Kim Le, Hady Saheb Department of Ophthalmology, McGill University, Montreal, QC, Canada Abstract: Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm’s canal. iStents are typically implanted at the time of phacoemulsification for patients with open-angle glaucoma and visually significant cataracts. This review summarizes the published data regarding the efficacy, safety, and cost considerations of trabecular micro-bypass stents. Most studies found statistically significant reductions in mean IOP and ocular medication use after combined phacoemulsification with single or double iStent implantation. The devices were found to be very safe, with a safety profile similar to that of cataract surgery. Complications were infrequent, with the most common complications being temporary stent obstruction or malposition, which resolved with observation or secondary procedures. Future studies are needed to evaluate long-term outcomes, patient satisfaction, cost effectiveness, and expanded indications. Keywords: iStent, trabecular micro-bypass, glaucoma, MIGS, ab interno, surgery
url http://www.dovepress.com/istent-trabecular-micro-bypass-stent-for-open-angle-glaucoma-peer-reviewed-article-OPTH
work_keys_str_mv AT lek istenttrabecularmicrobypassstentforopenangleglaucoma
AT sahebh istenttrabecularmicrobypassstentforopenangleglaucoma
_version_ 1725010121198665728