Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis

Introduction: Surgical approaches to treat patients with abnormal pro-inflammatory parameters remain controversial, and the debate on the correlation between hematological parameter alteration in cardiac implantable electronic device (CIED) infection and the increase in mortality continues.Methods:...

Full description

Bibliographic Details
Main Authors: Stefania Zerbo, Giulio Perrone, Clio Bilotta, Valeria Adelfio, Ginevra Malta, Pietro Di Pasquale, Emiliano Maresi, Antonina Argo
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-05-01
Series:Frontiers in Cardiovascular Medicine
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fcvm.2021.602275/full
id doaj-e78e438d58e84d16bf28c6584717ac3e
record_format Article
spelling doaj-e78e438d58e84d16bf28c6584717ac3e2021-05-03T04:24:08ZengFrontiers Media S.A.Frontiers in Cardiovascular Medicine2297-055X2021-05-01810.3389/fcvm.2021.602275602275Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-AnalysisStefania Zerbo0Giulio Perrone1Clio Bilotta2Valeria Adelfio3Ginevra Malta4Pietro Di Pasquale5Emiliano Maresi6Antonina Argo7Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, ItalyDepartment of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, ItalyDepartment of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, ItalyDepartment of Economics, Business and Statistics, University of Palermo, Palermo, ItalyDepartment of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, ItalyDivision of Cardiology, Paolo Borsellino, G.F. Ingrassia Hospital, Palermo, ItalyDepartment of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, ItalyDepartment of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, ItalyIntroduction: Surgical approaches to treat patients with abnormal pro-inflammatory parameters remain controversial, and the debate on the correlation between hematological parameter alteration in cardiac implantable electronic device (CIED) infection and the increase in mortality continues.Methods: We performed a systematic review using the PubMed, Scopus, and Cochrane Library databases. Twenty-two articles from May 2007 to April 2020 were selected and divided according to the following topics: prevalence of microbes in patients with CIED infection; characteristics of patients with CIED infection; comparison between patients who underwent and did not undergo replantation after device extraction; and correlation between alteration of hematological parameters and poor prognosis analysis.Results: Epidemiological analysis confirmed high prevalence of male sex, staphylococcal infection, and coagulase-negative staphylococci (CoNS). The most common comorbidity was heart failure. Complete removal of CIED and antimicrobial therapy combination are the gold standard. CIED replacement was associated with higher survival. High preoperative white blood cell count and C-reactive protein levels increased the risk of right ventricular failure (RVF) development. Increased red blood cell distribution width (RDW) value or decreased platelet count was correlated with poor prognosis. No correlation was noted between preoperative leukocytosis and CIED infection.Discussion: A relevant correlation between leukocytosis and RVF was observed. Heart failure may be related to high RDW values and decreased platelet count. Data on the correlation between hematological parameter alteration and poor prognosis are missing in many studies because of delayed implantation in patients showing signs of infection.https://www.frontiersin.org/articles/10.3389/fcvm.2021.602275/fullmicrobiologyheart failureinflammatory markersrisk factorsCIED infection
collection DOAJ
language English
format Article
sources DOAJ
author Stefania Zerbo
Giulio Perrone
Clio Bilotta
Valeria Adelfio
Ginevra Malta
Pietro Di Pasquale
Emiliano Maresi
Antonina Argo
spellingShingle Stefania Zerbo
Giulio Perrone
Clio Bilotta
Valeria Adelfio
Ginevra Malta
Pietro Di Pasquale
Emiliano Maresi
Antonina Argo
Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis
Frontiers in Cardiovascular Medicine
microbiology
heart failure
inflammatory markers
risk factors
CIED infection
author_facet Stefania Zerbo
Giulio Perrone
Clio Bilotta
Valeria Adelfio
Ginevra Malta
Pietro Di Pasquale
Emiliano Maresi
Antonina Argo
author_sort Stefania Zerbo
title Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis
title_short Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis
title_full Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis
title_fullStr Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis
title_full_unstemmed Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis
title_sort cardiovascular implantable electronic device infection and new insights about correlation between pro-inflammatory markers and heart failure: a systematic literature review and meta-analysis
publisher Frontiers Media S.A.
series Frontiers in Cardiovascular Medicine
issn 2297-055X
publishDate 2021-05-01
description Introduction: Surgical approaches to treat patients with abnormal pro-inflammatory parameters remain controversial, and the debate on the correlation between hematological parameter alteration in cardiac implantable electronic device (CIED) infection and the increase in mortality continues.Methods: We performed a systematic review using the PubMed, Scopus, and Cochrane Library databases. Twenty-two articles from May 2007 to April 2020 were selected and divided according to the following topics: prevalence of microbes in patients with CIED infection; characteristics of patients with CIED infection; comparison between patients who underwent and did not undergo replantation after device extraction; and correlation between alteration of hematological parameters and poor prognosis analysis.Results: Epidemiological analysis confirmed high prevalence of male sex, staphylococcal infection, and coagulase-negative staphylococci (CoNS). The most common comorbidity was heart failure. Complete removal of CIED and antimicrobial therapy combination are the gold standard. CIED replacement was associated with higher survival. High preoperative white blood cell count and C-reactive protein levels increased the risk of right ventricular failure (RVF) development. Increased red blood cell distribution width (RDW) value or decreased platelet count was correlated with poor prognosis. No correlation was noted between preoperative leukocytosis and CIED infection.Discussion: A relevant correlation between leukocytosis and RVF was observed. Heart failure may be related to high RDW values and decreased platelet count. Data on the correlation between hematological parameter alteration and poor prognosis are missing in many studies because of delayed implantation in patients showing signs of infection.
topic microbiology
heart failure
inflammatory markers
risk factors
CIED infection
url https://www.frontiersin.org/articles/10.3389/fcvm.2021.602275/full
work_keys_str_mv AT stefaniazerbo cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
AT giulioperrone cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
AT cliobilotta cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
AT valeriaadelfio cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
AT ginevramalta cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
AT pietrodipasquale cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
AT emilianomaresi cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
AT antoninaargo cardiovascularimplantableelectronicdeviceinfectionandnewinsightsaboutcorrelationbetweenproinflammatorymarkersandheartfailureasystematicliteraturereviewandmetaanalysis
_version_ 1721484296928100352