Phasor Estimation of Transient Electrical Signals Composed of Harmonics and Interharmonics
Numerical relays have become essential tools for carrying out the protection and surveillance tasks of electrical power systems. These relays implement their functions from the phasors of the electrical network signals, estimated by digital processing using digital filters. Digital filters must meet...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-08-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/16/5166 |
id |
doaj-e75dee2d525148feaa198f66977bfeb1 |
---|---|
record_format |
Article |
spelling |
doaj-e75dee2d525148feaa198f66977bfeb12021-08-26T13:43:40ZengMDPI AGEnergies1996-10732021-08-01145166516610.3390/en14165166Phasor Estimation of Transient Electrical Signals Composed of Harmonics and InterharmonicsJon Vazquez0Jose Felix Miñambres1Miguel Angel Zorrozua2Jorge Lázaro3Department of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, Plaza Ingeniero Torres Quevedo 1, 48013 Bilbao, SpainDepartment of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, Plaza Ingeniero Torres Quevedo 1, 48013 Bilbao, SpainDepartment of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, Plaza Ingeniero Torres Quevedo 1, 48013 Bilbao, SpainDepartment of Applied Mathematics, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, Plaza Ingeniero Torres Quevedo 1, 48013 Bilbao, SpainNumerical relays have become essential tools for carrying out the protection and surveillance tasks of electrical power systems. These relays implement their functions from the phasors of the electrical network signals, estimated by digital processing using digital filters. Digital filters must meet certain requirements, such as providing a fast and effective response to increasingly complex transient signals made up of components that make the estimation process difficult. In addition to the decreasing exponential (decaying dc offset), harmonics, and signal noise, it must be added that the interharmonic components that in recent years have acquired great relevance, mainly because of the increase in non-linear loads and the extensive use of power electronic systems. The presence of these interharmonic components causes a poor response in most of the filters implemented today. This article presents the design of a new digital filter, C-CharmDF (Cleaned Characteristic Harmonic Digital Filter) for phasor estimation on noisy transient signals with decreasing exponential components, harmonics, and interharmonics. A detailed study was carried out for severe transient situations and stationary signals. It was found that the method can be suitable for relays that implement both fault location functions and system protection functions.https://www.mdpi.com/1996-1073/14/16/5166digital filtersignal processingtransient eventfault signalfault localizationdecaying dc offset |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jon Vazquez Jose Felix Miñambres Miguel Angel Zorrozua Jorge Lázaro |
spellingShingle |
Jon Vazquez Jose Felix Miñambres Miguel Angel Zorrozua Jorge Lázaro Phasor Estimation of Transient Electrical Signals Composed of Harmonics and Interharmonics Energies digital filter signal processing transient event fault signal fault localization decaying dc offset |
author_facet |
Jon Vazquez Jose Felix Miñambres Miguel Angel Zorrozua Jorge Lázaro |
author_sort |
Jon Vazquez |
title |
Phasor Estimation of Transient Electrical Signals Composed of Harmonics and Interharmonics |
title_short |
Phasor Estimation of Transient Electrical Signals Composed of Harmonics and Interharmonics |
title_full |
Phasor Estimation of Transient Electrical Signals Composed of Harmonics and Interharmonics |
title_fullStr |
Phasor Estimation of Transient Electrical Signals Composed of Harmonics and Interharmonics |
title_full_unstemmed |
Phasor Estimation of Transient Electrical Signals Composed of Harmonics and Interharmonics |
title_sort |
phasor estimation of transient electrical signals composed of harmonics and interharmonics |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2021-08-01 |
description |
Numerical relays have become essential tools for carrying out the protection and surveillance tasks of electrical power systems. These relays implement their functions from the phasors of the electrical network signals, estimated by digital processing using digital filters. Digital filters must meet certain requirements, such as providing a fast and effective response to increasingly complex transient signals made up of components that make the estimation process difficult. In addition to the decreasing exponential (decaying dc offset), harmonics, and signal noise, it must be added that the interharmonic components that in recent years have acquired great relevance, mainly because of the increase in non-linear loads and the extensive use of power electronic systems. The presence of these interharmonic components causes a poor response in most of the filters implemented today. This article presents the design of a new digital filter, C-CharmDF (Cleaned Characteristic Harmonic Digital Filter) for phasor estimation on noisy transient signals with decreasing exponential components, harmonics, and interharmonics. A detailed study was carried out for severe transient situations and stationary signals. It was found that the method can be suitable for relays that implement both fault location functions and system protection functions. |
topic |
digital filter signal processing transient event fault signal fault localization decaying dc offset |
url |
https://www.mdpi.com/1996-1073/14/16/5166 |
work_keys_str_mv |
AT jonvazquez phasorestimationoftransientelectricalsignalscomposedofharmonicsandinterharmonics AT josefelixminambres phasorestimationoftransientelectricalsignalscomposedofharmonicsandinterharmonics AT miguelangelzorrozua phasorestimationoftransientelectricalsignalscomposedofharmonicsandinterharmonics AT jorgelazaro phasorestimationoftransientelectricalsignalscomposedofharmonicsandinterharmonics |
_version_ |
1721193756349169664 |