STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE

The paper presents the results of a preliminary study on the structural analysis of the pelvic girdle, comparing results for the analysis performed before and after the hip replacement procedure with taking into account changes in the mechanical properties of the articular cartilage of the joint. Ba...

Full description

Bibliographic Details
Main Authors: Ja. Zubrzycki, R. Karpinski, L. Jaworski, A. M. Ausiyevich, N. Smidova
Format: Article
Language:Russian
Published: Belarusian National Technical University 2018-04-01
Series:Nauka i Tehnika
Subjects:
Online Access:https://sat.bntu.by/jour/article/view/1504
id doaj-e755e0cc324b4effb15179d5ca7ab4ae
record_format Article
spelling doaj-e755e0cc324b4effb15179d5ca7ab4ae2021-07-29T08:29:35ZrusBelarusian National Technical UniversityNauka i Tehnika2227-10312414-03922018-04-0117216517210.21122/2227-1031-2018-17-2-165-1721408STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDUREJa. Zubrzycki0R. Karpinski1L. Jaworski2A. M. Ausiyevich3N. Smidova4Lublin University of TechnologyLublin University of TechnologyPoznan University of TechnologyBelarusian National Technical UniversityTechnical University of KošiceThe paper presents the results of a preliminary study on the structural analysis of the pelvic girdle, comparing results for the analysis performed before and after the hip replacement procedure with taking into account changes in the mechanical properties of the articular cartilage of the joint. Basic anatomy and biomechanics of the hip joint is introduced. The mechanical analysis of the hip joint model in each case is conducted. Final results of analysis are presented. The numerical model of the tested objects was made on the basis of CT and CAD modeling. Hip bone models were made using specialist software such as Materialise Mimics. The model is made in the program was then exported to a data exchange file in order to obtain the editable CAD files. Thus obtained models were the starting point for the implementation of the numerical model of personalized hip replacement. Numerical models of bone and implant were performed in Solidworks environment.Mechanical analysis was carried out using finite element analysis. During performing of calculations with the use of finite element analysis other physical quantities are also being discretized: loads, tensions, restraints or other examples represented in the system with the use of continuous function. While performing the process of discretization software aims at maximally approximation of discreet and continuous form using approximation methods.https://sat.bntu.by/jour/article/view/1504hip jointpelvisfemurendoprosthesisfinite element analysis
collection DOAJ
language Russian
format Article
sources DOAJ
author Ja. Zubrzycki
R. Karpinski
L. Jaworski
A. M. Ausiyevich
N. Smidova
spellingShingle Ja. Zubrzycki
R. Karpinski
L. Jaworski
A. M. Ausiyevich
N. Smidova
STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE
Nauka i Tehnika
hip joint
pelvis
femur
endoprosthesis
finite element analysis
author_facet Ja. Zubrzycki
R. Karpinski
L. Jaworski
A. M. Ausiyevich
N. Smidova
author_sort Ja. Zubrzycki
title STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE
title_short STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE
title_full STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE
title_fullStr STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE
title_full_unstemmed STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE
title_sort structural analysis of the pelvic girdle before and after hip replacement procedure
publisher Belarusian National Technical University
series Nauka i Tehnika
issn 2227-1031
2414-0392
publishDate 2018-04-01
description The paper presents the results of a preliminary study on the structural analysis of the pelvic girdle, comparing results for the analysis performed before and after the hip replacement procedure with taking into account changes in the mechanical properties of the articular cartilage of the joint. Basic anatomy and biomechanics of the hip joint is introduced. The mechanical analysis of the hip joint model in each case is conducted. Final results of analysis are presented. The numerical model of the tested objects was made on the basis of CT and CAD modeling. Hip bone models were made using specialist software such as Materialise Mimics. The model is made in the program was then exported to a data exchange file in order to obtain the editable CAD files. Thus obtained models were the starting point for the implementation of the numerical model of personalized hip replacement. Numerical models of bone and implant were performed in Solidworks environment.Mechanical analysis was carried out using finite element analysis. During performing of calculations with the use of finite element analysis other physical quantities are also being discretized: loads, tensions, restraints or other examples represented in the system with the use of continuous function. While performing the process of discretization software aims at maximally approximation of discreet and continuous form using approximation methods.
topic hip joint
pelvis
femur
endoprosthesis
finite element analysis
url https://sat.bntu.by/jour/article/view/1504
work_keys_str_mv AT jazubrzycki structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure
AT rkarpinski structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure
AT ljaworski structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure
AT amausiyevich structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure
AT nsmidova structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure
_version_ 1721255466693033984