STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE
The paper presents the results of a preliminary study on the structural analysis of the pelvic girdle, comparing results for the analysis performed before and after the hip replacement procedure with taking into account changes in the mechanical properties of the articular cartilage of the joint. Ba...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2018-04-01
|
Series: | Nauka i Tehnika |
Subjects: | |
Online Access: | https://sat.bntu.by/jour/article/view/1504 |
id |
doaj-e755e0cc324b4effb15179d5ca7ab4ae |
---|---|
record_format |
Article |
spelling |
doaj-e755e0cc324b4effb15179d5ca7ab4ae2021-07-29T08:29:35ZrusBelarusian National Technical UniversityNauka i Tehnika2227-10312414-03922018-04-0117216517210.21122/2227-1031-2018-17-2-165-1721408STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDUREJa. Zubrzycki0R. Karpinski1L. Jaworski2A. M. Ausiyevich3N. Smidova4Lublin University of TechnologyLublin University of TechnologyPoznan University of TechnologyBelarusian National Technical UniversityTechnical University of KošiceThe paper presents the results of a preliminary study on the structural analysis of the pelvic girdle, comparing results for the analysis performed before and after the hip replacement procedure with taking into account changes in the mechanical properties of the articular cartilage of the joint. Basic anatomy and biomechanics of the hip joint is introduced. The mechanical analysis of the hip joint model in each case is conducted. Final results of analysis are presented. The numerical model of the tested objects was made on the basis of CT and CAD modeling. Hip bone models were made using specialist software such as Materialise Mimics. The model is made in the program was then exported to a data exchange file in order to obtain the editable CAD files. Thus obtained models were the starting point for the implementation of the numerical model of personalized hip replacement. Numerical models of bone and implant were performed in Solidworks environment.Mechanical analysis was carried out using finite element analysis. During performing of calculations with the use of finite element analysis other physical quantities are also being discretized: loads, tensions, restraints or other examples represented in the system with the use of continuous function. While performing the process of discretization software aims at maximally approximation of discreet and continuous form using approximation methods.https://sat.bntu.by/jour/article/view/1504hip jointpelvisfemurendoprosthesisfinite element analysis |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
Ja. Zubrzycki R. Karpinski L. Jaworski A. M. Ausiyevich N. Smidova |
spellingShingle |
Ja. Zubrzycki R. Karpinski L. Jaworski A. M. Ausiyevich N. Smidova STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE Nauka i Tehnika hip joint pelvis femur endoprosthesis finite element analysis |
author_facet |
Ja. Zubrzycki R. Karpinski L. Jaworski A. M. Ausiyevich N. Smidova |
author_sort |
Ja. Zubrzycki |
title |
STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE |
title_short |
STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE |
title_full |
STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE |
title_fullStr |
STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE |
title_full_unstemmed |
STRUCTURAL ANALYSIS OF THE PELVIC GIRDLE BEFORE AND AFTER HIP REPLACEMENT PROCEDURE |
title_sort |
structural analysis of the pelvic girdle before and after hip replacement procedure |
publisher |
Belarusian National Technical University |
series |
Nauka i Tehnika |
issn |
2227-1031 2414-0392 |
publishDate |
2018-04-01 |
description |
The paper presents the results of a preliminary study on the structural analysis of the pelvic girdle, comparing results for the analysis performed before and after the hip replacement procedure with taking into account changes in the mechanical properties of the articular cartilage of the joint. Basic anatomy and biomechanics of the hip joint is introduced. The mechanical analysis of the hip joint model in each case is conducted. Final results of analysis are presented. The numerical model of the tested objects was made on the basis of CT and CAD modeling. Hip bone models were made using specialist software such as Materialise Mimics. The model is made in the program was then exported to a data exchange file in order to obtain the editable CAD files. Thus obtained models were the starting point for the implementation of the numerical model of personalized hip replacement. Numerical models of bone and implant were performed in Solidworks environment.Mechanical analysis was carried out using finite element analysis. During performing of calculations with the use of finite element analysis other physical quantities are also being discretized: loads, tensions, restraints or other examples represented in the system with the use of continuous function. While performing the process of discretization software aims at maximally approximation of discreet and continuous form using approximation methods. |
topic |
hip joint pelvis femur endoprosthesis finite element analysis |
url |
https://sat.bntu.by/jour/article/view/1504 |
work_keys_str_mv |
AT jazubrzycki structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure AT rkarpinski structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure AT ljaworski structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure AT amausiyevich structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure AT nsmidova structuralanalysisofthepelvicgirdlebeforeandafterhipreplacementprocedure |
_version_ |
1721255466693033984 |