Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

PurposeTo validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol.MethodsForty-fi...

Full description

Bibliographic Details
Main Authors: Chong Guk Lee, Hyang Mi Park, Hye Jung Shin, Jin Soo Moon, Yeong Mi Hong, Nam Soo Kim, Il Soo Ha, Myeong Jin Chang, Kyeong Won Oh
Format: Article
Language:English
Published: Korean Pediatric Society 2011-11-01
Series:Korean Journal of Pediatrics
Subjects:
Online Access:http://kjp.or.kr/upload/pdf/kjped-54-463.pdf
id doaj-e6146676fef6467b8499c3253d0e83eb
record_format Article
spelling doaj-e6146676fef6467b8499c3253d0e83eb2020-11-24T20:45:57ZengKorean Pediatric SocietyKorean Journal of Pediatrics1738-10612092-72582011-11-01541146346910.3345/kjp.2011.54.11.4632011541105Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescentsChong Guk Lee0Hyang Mi Park1Hye Jung Shin2Jin Soo Moon3Yeong Mi Hong4Nam Soo Kim5Il Soo Ha6Myeong Jin Chang7Kyeong Won Oh8Department of Pediatrics, Inje University Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Korea.Department of Pediatrics, National Medical Center, Seoul, Korea.Department of Pediatrics, National Medical Center, Seoul, Korea.Department of Pediatrics, Inje University Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Korea.Department of Pediatrics, Ewha Womans University Mockdong Hospital, Ewha Womans University School of Medicine, Seoul, Korea.Department of Pediatrics, Hanyang University Seoul Hospital, Hanyang University College of Medicine, Seoul, Korea.Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea.Department of Chronic Disease Investigation, Korea Center for Disease and Prevention, Seoul, Korea.Department of Chronic Disease Investigation, Korea Center for Disease and Prevention, Seoul, Korea.PurposeTo validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol.MethodsForty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2.ResultsThe mean (±SD) difference in the absolute BP values between test device and mercury sphygmomanometer readings was 1.85±1.65 mmHg for systolic BP (SBP) and 4.41±3.53 mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean±SD below 5±8 mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed.ConclusionAlthough the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated.http://kjp.or.kr/upload/pdf/kjped-54-463.pdfBlood pressureOscillometric deviceDinamapValidation studiesInternational protocol
collection DOAJ
language English
format Article
sources DOAJ
author Chong Guk Lee
Hyang Mi Park
Hye Jung Shin
Jin Soo Moon
Yeong Mi Hong
Nam Soo Kim
Il Soo Ha
Myeong Jin Chang
Kyeong Won Oh
spellingShingle Chong Guk Lee
Hyang Mi Park
Hye Jung Shin
Jin Soo Moon
Yeong Mi Hong
Nam Soo Kim
Il Soo Ha
Myeong Jin Chang
Kyeong Won Oh
Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
Korean Journal of Pediatrics
Blood pressure
Oscillometric device
Dinamap
Validation studies
International protocol
author_facet Chong Guk Lee
Hyang Mi Park
Hye Jung Shin
Jin Soo Moon
Yeong Mi Hong
Nam Soo Kim
Il Soo Ha
Myeong Jin Chang
Kyeong Won Oh
author_sort Chong Guk Lee
title Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_short Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_full Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_fullStr Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_full_unstemmed Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
title_sort validation study of the dinamap procare 200 upper arm blood pressure monitor in children and adolescents
publisher Korean Pediatric Society
series Korean Journal of Pediatrics
issn 1738-1061
2092-7258
publishDate 2011-11-01
description PurposeTo validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol.MethodsForty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2.ResultsThe mean (±SD) difference in the absolute BP values between test device and mercury sphygmomanometer readings was 1.85±1.65 mmHg for systolic BP (SBP) and 4.41±3.53 mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean±SD below 5±8 mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed.ConclusionAlthough the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated.
topic Blood pressure
Oscillometric device
Dinamap
Validation studies
International protocol
url http://kjp.or.kr/upload/pdf/kjped-54-463.pdf
work_keys_str_mv AT chongguklee validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT hyangmipark validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT hyejungshin validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT jinsoomoon validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT yeongmihong validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT namsookim validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT ilsooha validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT myeongjinchang validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
AT kyeongwonoh validationstudyofthedinamapprocare200upperarmbloodpressuremonitorinchildrenandadolescents
_version_ 1716813644935725056