Can ozone be used to calibrate aerosol photoacoustic spectrometers?

<p>Photoacoustic spectroscopy (PAS) has become a popular technique for measuring absorption of light by atmospheric aerosols in both the laboratory and field campaigns. It has low detection limits, measures suspended aerosols, and is insensitive to scattering. But PAS requires rigorous calibra...

Full description

Bibliographic Details
Main Authors: D. A. Fischer, G. D. Smith
Format: Article
Language:English
Published: Copernicus Publications 2018-12-01
Series:Atmospheric Measurement Techniques
Online Access:https://www.atmos-meas-tech.net/11/6419/2018/amt-11-6419-2018.pdf
id doaj-e56069364e1242998ea88eb6decd9cbe
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author D. A. Fischer
D. A. Fischer
G. D. Smith
spellingShingle D. A. Fischer
D. A. Fischer
G. D. Smith
Can ozone be used to calibrate aerosol photoacoustic spectrometers?
Atmospheric Measurement Techniques
author_facet D. A. Fischer
D. A. Fischer
G. D. Smith
author_sort D. A. Fischer
title Can ozone be used to calibrate aerosol photoacoustic spectrometers?
title_short Can ozone be used to calibrate aerosol photoacoustic spectrometers?
title_full Can ozone be used to calibrate aerosol photoacoustic spectrometers?
title_fullStr Can ozone be used to calibrate aerosol photoacoustic spectrometers?
title_full_unstemmed Can ozone be used to calibrate aerosol photoacoustic spectrometers?
title_sort can ozone be used to calibrate aerosol photoacoustic spectrometers?
publisher Copernicus Publications
series Atmospheric Measurement Techniques
issn 1867-1381
1867-8548
publishDate 2018-12-01
description <p>Photoacoustic spectroscopy (PAS) has become a popular technique for measuring absorption of light by atmospheric aerosols in both the laboratory and field campaigns. It has low detection limits, measures suspended aerosols, and is insensitive to scattering. But PAS requires rigorous calibration to be applied quantitatively. Often, a PAS instrument is either filled with a gas of known concentration and absorption cross section, such that the absorption in the cell can be calculated from the product of the two, or the absorption is measured independently with a technique such as cavity ring-down spectroscopy. Then, the PAS signal can be regressed upon the known absorption to determine a calibration slope that reflects the sensitivity constant of the cell and microphone. Ozone has been used for calibrating PAS instruments due to its well-known UV–visible absorption spectrum and the ease with which it can be generated. However, it is known to photodissociate up to approximately 1120&thinsp;nm via the <span class="inline-formula">O<sub>3</sub></span> <span class="inline-formula">+</span> <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M3" display="inline" overflow="scroll" dspmath="mathml"><mrow><mi>h</mi><mi mathvariant="italic">ν</mi><mspace linebreak="nobreak" width="0.25em"/><mo>(</mo><mo>&gt;</mo><mn mathvariant="normal">1.1</mn><mi mathvariant="normal">eV</mi><mo>)</mo><mo>→</mo><mrow class="chem"><msub><mi mathvariant="normal">O</mi><mn mathvariant="normal">2</mn></msub></mrow><msup><mo>(</mo><mn mathvariant="normal">3</mn></msup><msubsup><mi mathvariant="normal">Σ</mi><mi>g</mi><mo>-</mo></msubsup><mo>)</mo></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="117pt" height="17pt" class="svg-formula" dspmath="mathimg" md5hash="2540a17128385cdeb672d3ea6820a4f8"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-11-6419-2018-ie00001.svg" width="117pt" height="17pt" src="amt-11-6419-2018-ie00001.png"/></svg:svg></span></span> <span class="inline-formula">+</span> <span class="inline-formula">O(<sup>3</sup>P)</span> pathway, which is likely to lead to inaccuracies in aerosol measurements. Two recent studies have investigated the use of <span class="inline-formula">O<sub>3</sub></span> for PAS calibration but have reached seemingly contradictory conclusions with one finding that it results in a sensitivity that is a factor of 2 low and the other concluding that it is accurate. The present work is meant to add to this discussion by exploring the extent to which <span class="inline-formula">O<sub>3</sub></span> photodissociates in the PAS cell and the role that the identity of the bath gas plays in determining the PAS sensitivity. We find a 5&thinsp;% loss in PAS signal attributable to photodissociation at 532&thinsp;nm in <span class="inline-formula">N<sub>2</sub></span> but no loss in a 5&thinsp;% mixture of <span class="inline-formula">O<sub>2</sub></span> in <span class="inline-formula">N<sub>2</sub></span>. Furthermore, we discovered a dramatic increase of more than a factor of 2 in the PAS sensitivity as we increased the <span class="inline-formula">O<sub>2</sub></span> fraction in the bath gas, which reached an asymptote near 100&thinsp;% <span class="inline-formula">O<sub>2</sub></span> that nearly matched the sensitivity measured with both <span class="inline-formula">NO<sub>2</sub></span> and nigrosin particles. We interpret this dependence with a kinetic model that suggests the reason for the observed results is a more efficient transfer of energy from excited <span class="inline-formula">O<sub>3</sub></span> to <span class="inline-formula">O<sub>2</sub></span> than to <span class="inline-formula">N<sub>2</sub></span> by a factor of 22–55 depending on excitation wavelength. Notably, the two prior studies on this topic used different bath gas compositions, and although the results presented here do not fully resolve the differences in their results, they may at least partially explain them.</p>
url https://www.atmos-meas-tech.net/11/6419/2018/amt-11-6419-2018.pdf
work_keys_str_mv AT dafischer canozonebeusedtocalibrateaerosolphotoacousticspectrometers
AT dafischer canozonebeusedtocalibrateaerosolphotoacousticspectrometers
AT gdsmith canozonebeusedtocalibrateaerosolphotoacousticspectrometers
_version_ 1716789791670927360
spelling doaj-e56069364e1242998ea88eb6decd9cbe2020-11-24T20:56:24ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482018-12-01116419642710.5194/amt-11-6419-2018Can ozone be used to calibrate aerosol photoacoustic spectrometers?D. A. Fischer0D. A. Fischer1G. D. Smith2Department of Chemistry, University of Georgia, 140 Cedar Street, Athens, Georgia 30602, USAcurrent address: Department of Chemistry and Physics, Western Carolina University, 111 Memorial Drive, Cullowhee, NC 28723, USADepartment of Chemistry, University of Georgia, 140 Cedar Street, Athens, Georgia 30602, USA<p>Photoacoustic spectroscopy (PAS) has become a popular technique for measuring absorption of light by atmospheric aerosols in both the laboratory and field campaigns. It has low detection limits, measures suspended aerosols, and is insensitive to scattering. But PAS requires rigorous calibration to be applied quantitatively. Often, a PAS instrument is either filled with a gas of known concentration and absorption cross section, such that the absorption in the cell can be calculated from the product of the two, or the absorption is measured independently with a technique such as cavity ring-down spectroscopy. Then, the PAS signal can be regressed upon the known absorption to determine a calibration slope that reflects the sensitivity constant of the cell and microphone. Ozone has been used for calibrating PAS instruments due to its well-known UV–visible absorption spectrum and the ease with which it can be generated. However, it is known to photodissociate up to approximately 1120&thinsp;nm via the <span class="inline-formula">O<sub>3</sub></span> <span class="inline-formula">+</span> <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M3" display="inline" overflow="scroll" dspmath="mathml"><mrow><mi>h</mi><mi mathvariant="italic">ν</mi><mspace linebreak="nobreak" width="0.25em"/><mo>(</mo><mo>&gt;</mo><mn mathvariant="normal">1.1</mn><mi mathvariant="normal">eV</mi><mo>)</mo><mo>→</mo><mrow class="chem"><msub><mi mathvariant="normal">O</mi><mn mathvariant="normal">2</mn></msub></mrow><msup><mo>(</mo><mn mathvariant="normal">3</mn></msup><msubsup><mi mathvariant="normal">Σ</mi><mi>g</mi><mo>-</mo></msubsup><mo>)</mo></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="117pt" height="17pt" class="svg-formula" dspmath="mathimg" md5hash="2540a17128385cdeb672d3ea6820a4f8"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-11-6419-2018-ie00001.svg" width="117pt" height="17pt" src="amt-11-6419-2018-ie00001.png"/></svg:svg></span></span> <span class="inline-formula">+</span> <span class="inline-formula">O(<sup>3</sup>P)</span> pathway, which is likely to lead to inaccuracies in aerosol measurements. Two recent studies have investigated the use of <span class="inline-formula">O<sub>3</sub></span> for PAS calibration but have reached seemingly contradictory conclusions with one finding that it results in a sensitivity that is a factor of 2 low and the other concluding that it is accurate. The present work is meant to add to this discussion by exploring the extent to which <span class="inline-formula">O<sub>3</sub></span> photodissociates in the PAS cell and the role that the identity of the bath gas plays in determining the PAS sensitivity. We find a 5&thinsp;% loss in PAS signal attributable to photodissociation at 532&thinsp;nm in <span class="inline-formula">N<sub>2</sub></span> but no loss in a 5&thinsp;% mixture of <span class="inline-formula">O<sub>2</sub></span> in <span class="inline-formula">N<sub>2</sub></span>. Furthermore, we discovered a dramatic increase of more than a factor of 2 in the PAS sensitivity as we increased the <span class="inline-formula">O<sub>2</sub></span> fraction in the bath gas, which reached an asymptote near 100&thinsp;% <span class="inline-formula">O<sub>2</sub></span> that nearly matched the sensitivity measured with both <span class="inline-formula">NO<sub>2</sub></span> and nigrosin particles. We interpret this dependence with a kinetic model that suggests the reason for the observed results is a more efficient transfer of energy from excited <span class="inline-formula">O<sub>3</sub></span> to <span class="inline-formula">O<sub>2</sub></span> than to <span class="inline-formula">N<sub>2</sub></span> by a factor of 22–55 depending on excitation wavelength. Notably, the two prior studies on this topic used different bath gas compositions, and although the results presented here do not fully resolve the differences in their results, they may at least partially explain them.</p>https://www.atmos-meas-tech.net/11/6419/2018/amt-11-6419-2018.pdf