Defining the power system load frequency static response slope based on transient synchrophasor data

The method is proposed for defining the power system load frequency static response based on synchrophasor measurements during transients accompanied by frequency deviations. The method was successfully validated involving four events resulting in frequency deviations in the Northern part of Tyumen...

Full description

Bibliographic Details
Main Authors: Berdin Alexander, Kovalenko Pavel
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201820804002
id doaj-e4b666b4d28c42ad9d6c964ada57e0ba
record_format Article
spelling doaj-e4b666b4d28c42ad9d6c964ada57e0ba2021-04-02T11:38:05ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-012080400210.1051/matecconf/201820804002matecconf_icmie2018_04002Defining the power system load frequency static response slope based on transient synchrophasor dataBerdin AlexanderKovalenko PavelThe method is proposed for defining the power system load frequency static response based on synchrophasor measurements during transients accompanied by frequency deviations. The method was successfully validated involving four events resulting in frequency deviations in the Northern part of Tyumen region of up to 0.06 Hz magnitude and recorded by means of the System operator WAMS.https://doi.org/10.1051/matecconf/201820804002
collection DOAJ
language English
format Article
sources DOAJ
author Berdin Alexander
Kovalenko Pavel
spellingShingle Berdin Alexander
Kovalenko Pavel
Defining the power system load frequency static response slope based on transient synchrophasor data
MATEC Web of Conferences
author_facet Berdin Alexander
Kovalenko Pavel
author_sort Berdin Alexander
title Defining the power system load frequency static response slope based on transient synchrophasor data
title_short Defining the power system load frequency static response slope based on transient synchrophasor data
title_full Defining the power system load frequency static response slope based on transient synchrophasor data
title_fullStr Defining the power system load frequency static response slope based on transient synchrophasor data
title_full_unstemmed Defining the power system load frequency static response slope based on transient synchrophasor data
title_sort defining the power system load frequency static response slope based on transient synchrophasor data
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2018-01-01
description The method is proposed for defining the power system load frequency static response based on synchrophasor measurements during transients accompanied by frequency deviations. The method was successfully validated involving four events resulting in frequency deviations in the Northern part of Tyumen region of up to 0.06 Hz magnitude and recorded by means of the System operator WAMS.
url https://doi.org/10.1051/matecconf/201820804002
work_keys_str_mv AT berdinalexander definingthepowersystemloadfrequencystaticresponseslopebasedontransientsynchrophasordata
AT kovalenkopavel definingthepowersystemloadfrequencystaticresponseslopebasedontransientsynchrophasordata
_version_ 1724164313690669056