Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units

Background and purpose : Instalation of protective barrier against diagnostic x-ray is generally done based on the recommendations of NCRP49. There are analytic methods for designing protective barriers howerer, they lack sufficient efficiency and considering the NCRP49 reports, designing mechanical...

Full description

Bibliographic Details
Main Authors: S.A. Rahimi, S. Sarkar, M.J. Abolhasani, S. Salar
Format: Article
Language:English
Published: Mazandaran University of Medical Sciences 2005-01-01
Series:Journal of Mazandaran University of Medical Sciences
Subjects:
Online Access:http://www.mazums.ac.ir/files/onlineJournals_2165814=rahimi.pdf
id doaj-e47325cf78014102874ed3d73065a39b
record_format Article
spelling doaj-e47325cf78014102874ed3d73065a39b2020-11-24T20:52:21ZengMazandaran University of Medical SciencesJournal of Mazandaran University of Medical Sciences1735-92602005-01-011547Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray unitsS.A. RahimiS. SarkarM.J. AbolhasaniS. SalarBackground and purpose : Instalation of protective barrier against diagnostic x-ray is generally done based on the recommendations of NCRP49. There are analytic methods for designing protective barriers howerer, they lack sufficient efficiency and considering the NCRP49 reports, designing mechanical protective barrier in order to protect the initial x-ray radiation and absorption of the ray quality of such radiation is different.Therefore, the protective barrier for each radiation is measured separately. In this study, a computer software was designed to calculate the needed barrier with high accuracy.Materials and methods: Calculation of required protective barrier particularly when two or more generators are in use at diagnostic x-ray units and or installed diagnostic equipments do not have proper room space and the limitations for other clanges in parameters which are time- consuming and impossible to be manually calculated. For proper determination of thichness of the protective barrier, relevant information about curves of radiation weakness, dose limit etc should be entered. This program was done in windows and designed in such a way that the operator works easily, flexibility of the program is acceptable and its accuracy and sensitivity is high.Results : Results of this program indicate that, in most cases, in x-ray units required protective barrier was not used. Meanwhile sometimes shielding is more than what required which lacks technical standards and cost effectiveness. When the application index is contrasting zero, thichness of NCRP49 calculation is about 20% less than the calculated rate done by the method of this study. When the applied index is equal to zero (that is the only situation where the second barrier is considered), thickness of requined barrier is about 15% less than the lead barrier and concrete barrier calculated in this project is 8% less than that calculated by McGuire method.Conclusion : In this study proper determination of required protective thickness for weakening of radiation to the permitable level is proposed. The multi radiation sources in a single room are considered and non garanteed radiation of NCRP49 hypothesis are removed. Difference between the the oritical and calculated rates this of method is X2=10-5 which indicates accuracy and high efficiency of this software. http://www.mazums.ac.ir/files/onlineJournals_2165814=rahimi.pdfAdditional Shieldingdiagnostic x-rayattenuation curvebuilding Materials
collection DOAJ
language English
format Article
sources DOAJ
author S.A. Rahimi
S. Sarkar
M.J. Abolhasani
S. Salar
spellingShingle S.A. Rahimi
S. Sarkar
M.J. Abolhasani
S. Salar
Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units
Journal of Mazandaran University of Medical Sciences
Additional Shielding
diagnostic x-ray
attenuation curve
building Materials
author_facet S.A. Rahimi
S. Sarkar
M.J. Abolhasani
S. Salar
author_sort S.A. Rahimi
title Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units
title_short Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units
title_full Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units
title_fullStr Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units
title_full_unstemmed Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units
title_sort design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units
publisher Mazandaran University of Medical Sciences
series Journal of Mazandaran University of Medical Sciences
issn 1735-9260
publishDate 2005-01-01
description Background and purpose : Instalation of protective barrier against diagnostic x-ray is generally done based on the recommendations of NCRP49. There are analytic methods for designing protective barriers howerer, they lack sufficient efficiency and considering the NCRP49 reports, designing mechanical protective barrier in order to protect the initial x-ray radiation and absorption of the ray quality of such radiation is different.Therefore, the protective barrier for each radiation is measured separately. In this study, a computer software was designed to calculate the needed barrier with high accuracy.Materials and methods: Calculation of required protective barrier particularly when two or more generators are in use at diagnostic x-ray units and or installed diagnostic equipments do not have proper room space and the limitations for other clanges in parameters which are time- consuming and impossible to be manually calculated. For proper determination of thichness of the protective barrier, relevant information about curves of radiation weakness, dose limit etc should be entered. This program was done in windows and designed in such a way that the operator works easily, flexibility of the program is acceptable and its accuracy and sensitivity is high.Results : Results of this program indicate that, in most cases, in x-ray units required protective barrier was not used. Meanwhile sometimes shielding is more than what required which lacks technical standards and cost effectiveness. When the application index is contrasting zero, thichness of NCRP49 calculation is about 20% less than the calculated rate done by the method of this study. When the applied index is equal to zero (that is the only situation where the second barrier is considered), thickness of requined barrier is about 15% less than the lead barrier and concrete barrier calculated in this project is 8% less than that calculated by McGuire method.Conclusion : In this study proper determination of required protective thickness for weakening of radiation to the permitable level is proposed. The multi radiation sources in a single room are considered and non garanteed radiation of NCRP49 hypothesis are removed. Difference between the the oritical and calculated rates this of method is X2=10-5 which indicates accuracy and high efficiency of this software.
topic Additional Shielding
diagnostic x-ray
attenuation curve
building Materials
url http://www.mazums.ac.ir/files/onlineJournals_2165814=rahimi.pdf
work_keys_str_mv AT sarahimi designofacomputersoftwareforcalculationofrequiredbarrieragainstradiationatthediagnosticxrayunits
AT ssarkar designofacomputersoftwareforcalculationofrequiredbarrieragainstradiationatthediagnosticxrayunits
AT mjabolhasani designofacomputersoftwareforcalculationofrequiredbarrieragainstradiationatthediagnosticxrayunits
AT ssalar designofacomputersoftwareforcalculationofrequiredbarrieragainstradiationatthediagnosticxrayunits
_version_ 1716799971448061952