Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.

To prospectively examine the feasibility and accuracy of Contrast Enhanced Ultrasound (CEUS) in the assessment of Crohn's disease (CD) activity in the terminal ileum in comparison to Magnetic Resonance Enterography (MRE), using endoscopy as a reference standard.105 consecutive patients with all...

Full description

Bibliographic Details
Main Authors: C S Horjus Talabur Horje, R Bruijnen, L Roovers, M J M Groenen, F B M Joosten, P J Wahab
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4556376?pdf=render
id doaj-e42998ef60194bc88f181f0682004779
record_format Article
spelling doaj-e42998ef60194bc88f181f06820047792020-11-24T21:56:53ZengPublic Library of Science (PLoS)PLoS ONE1932-62032015-01-01108e013610510.1371/journal.pone.0136105Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.C S Horjus Talabur HorjeR BruijnenL RooversM J M GroenenF B M JoostenP J WahabTo prospectively examine the feasibility and accuracy of Contrast Enhanced Ultrasound (CEUS) in the assessment of Crohn's disease (CD) activity in the terminal ileum in comparison to Magnetic Resonance Enterography (MRE), using endoscopy as a reference standard.105 consecutive patients with alleged clinically active CD were assessed by MRE and CEUS. CEUS of the terminal ileum was performed using an intravenous microbubble contrast enhancer. Accuracy values of CEUS and MRE for the presence of active terminal ileitis were evaluated using the Receiver Operating Characteristic method, using endoscopic findings as a reference standard. Sensitivity and specificity values of MRE and CEUS were compared by the McNemar test.CEUS was feasible in 98% of patients, MRE in all. Optimal diagnostic accuracy in CEUS was obtained at a peak intensity value of 10%, showing 100% sensitivity, 92% specificity and an accuracy of 99% in demonstrating ileal mucosal inflammation. For MRE, overall sensitivity, specificity and accuracy were, 87%, 100%, and 88%, respectively. CEUS and MRE were highly correlated in assessing length and wall thickness of the terminal ileum. CEUS identified 11 of 16 MRE-detected strictures, but no fistulae.The accuracy of CEUS is comparable to that of MRE in the assessment of active, uncomplicated terminal ileal CD and therefore a valuable bedside alternative to MRE in the follow-up of these patients.http://europepmc.org/articles/PMC4556376?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author C S Horjus Talabur Horje
R Bruijnen
L Roovers
M J M Groenen
F B M Joosten
P J Wahab
spellingShingle C S Horjus Talabur Horje
R Bruijnen
L Roovers
M J M Groenen
F B M Joosten
P J Wahab
Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.
PLoS ONE
author_facet C S Horjus Talabur Horje
R Bruijnen
L Roovers
M J M Groenen
F B M Joosten
P J Wahab
author_sort C S Horjus Talabur Horje
title Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.
title_short Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.
title_full Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.
title_fullStr Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.
title_full_unstemmed Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.
title_sort contrast enhanced abdominal ultrasound in the assessment of ileal inflammation in crohn's disease: a comparison with mr enterography.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2015-01-01
description To prospectively examine the feasibility and accuracy of Contrast Enhanced Ultrasound (CEUS) in the assessment of Crohn's disease (CD) activity in the terminal ileum in comparison to Magnetic Resonance Enterography (MRE), using endoscopy as a reference standard.105 consecutive patients with alleged clinically active CD were assessed by MRE and CEUS. CEUS of the terminal ileum was performed using an intravenous microbubble contrast enhancer. Accuracy values of CEUS and MRE for the presence of active terminal ileitis were evaluated using the Receiver Operating Characteristic method, using endoscopic findings as a reference standard. Sensitivity and specificity values of MRE and CEUS were compared by the McNemar test.CEUS was feasible in 98% of patients, MRE in all. Optimal diagnostic accuracy in CEUS was obtained at a peak intensity value of 10%, showing 100% sensitivity, 92% specificity and an accuracy of 99% in demonstrating ileal mucosal inflammation. For MRE, overall sensitivity, specificity and accuracy were, 87%, 100%, and 88%, respectively. CEUS and MRE were highly correlated in assessing length and wall thickness of the terminal ileum. CEUS identified 11 of 16 MRE-detected strictures, but no fistulae.The accuracy of CEUS is comparable to that of MRE in the assessment of active, uncomplicated terminal ileal CD and therefore a valuable bedside alternative to MRE in the follow-up of these patients.
url http://europepmc.org/articles/PMC4556376?pdf=render
work_keys_str_mv AT cshorjustalaburhorje contrastenhancedabdominalultrasoundintheassessmentofilealinflammationincrohnsdiseaseacomparisonwithmrenterography
AT rbruijnen contrastenhancedabdominalultrasoundintheassessmentofilealinflammationincrohnsdiseaseacomparisonwithmrenterography
AT lroovers contrastenhancedabdominalultrasoundintheassessmentofilealinflammationincrohnsdiseaseacomparisonwithmrenterography
AT mjmgroenen contrastenhancedabdominalultrasoundintheassessmentofilealinflammationincrohnsdiseaseacomparisonwithmrenterography
AT fbmjoosten contrastenhancedabdominalultrasoundintheassessmentofilealinflammationincrohnsdiseaseacomparisonwithmrenterography
AT pjwahab contrastenhancedabdominalultrasoundintheassessmentofilealinflammationincrohnsdiseaseacomparisonwithmrenterography
_version_ 1725856588978192384