Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform Method

The present paper gives a new computational framework within which radiative transfer in a varying refractive index biological tissue can be studied. In our previous works, Legendre transform was used as an innovative view to handle the angular derivative terms in the case of uniform refractive inde...

Full description

Bibliographic Details
Main Author: M. Gantri
Format: Article
Language:English
Published: Hindawi Limited 2014-01-01
Series:Computational and Mathematical Methods in Medicine
Online Access:http://dx.doi.org/10.1155/2014/814929
id doaj-e34cbcc7e2984b3287a817a71097cef7
record_format Article
spelling doaj-e34cbcc7e2984b3287a817a71097cef72020-11-24T21:13:31ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-670X1748-67182014-01-01201410.1155/2014/814929814929Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform MethodM. Gantri0Unit of Thermal Radiation, Department of Physics, Faculty of Sciences of Tunis, Tunis El-Manar University, 1060 Tunis, TunisiaThe present paper gives a new computational framework within which radiative transfer in a varying refractive index biological tissue can be studied. In our previous works, Legendre transform was used as an innovative view to handle the angular derivative terms in the case of uniform refractive index spherical medium. In biomedical optics, our analysis can be considered as a forward problem solution in a diffuse optical tomography imaging scheme. We consider a rectangular biological tissue-like domain with spatially varying refractive index submitted to a near infrared continuous light source. Interaction of radiation with the biological material into the medium is handled by a radiative transfer model. In the studied situation, the model displays two angular redistribution terms that are treated with Legendre integral transform. The model is used to study a possible detection of abnormalities in a general biological tissue. The effect of the embedded nonhomogeneous objects on the transmitted signal is studied. Particularly, detection of targets of localized heterogeneous inclusions within the tissue is discussed. Results show that models accounting for variation of refractive index can yield useful predictions about the target and the location of abnormal inclusions within the tissue.http://dx.doi.org/10.1155/2014/814929
collection DOAJ
language English
format Article
sources DOAJ
author M. Gantri
spellingShingle M. Gantri
Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform Method
Computational and Mathematical Methods in Medicine
author_facet M. Gantri
author_sort M. Gantri
title Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform Method
title_short Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform Method
title_full Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform Method
title_fullStr Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform Method
title_full_unstemmed Solution of Radiative Transfer Equation with a Continuous and Stochastic Varying Refractive Index by Legendre Transform Method
title_sort solution of radiative transfer equation with a continuous and stochastic varying refractive index by legendre transform method
publisher Hindawi Limited
series Computational and Mathematical Methods in Medicine
issn 1748-670X
1748-6718
publishDate 2014-01-01
description The present paper gives a new computational framework within which radiative transfer in a varying refractive index biological tissue can be studied. In our previous works, Legendre transform was used as an innovative view to handle the angular derivative terms in the case of uniform refractive index spherical medium. In biomedical optics, our analysis can be considered as a forward problem solution in a diffuse optical tomography imaging scheme. We consider a rectangular biological tissue-like domain with spatially varying refractive index submitted to a near infrared continuous light source. Interaction of radiation with the biological material into the medium is handled by a radiative transfer model. In the studied situation, the model displays two angular redistribution terms that are treated with Legendre integral transform. The model is used to study a possible detection of abnormalities in a general biological tissue. The effect of the embedded nonhomogeneous objects on the transmitted signal is studied. Particularly, detection of targets of localized heterogeneous inclusions within the tissue is discussed. Results show that models accounting for variation of refractive index can yield useful predictions about the target and the location of abnormal inclusions within the tissue.
url http://dx.doi.org/10.1155/2014/814929
work_keys_str_mv AT mgantri solutionofradiativetransferequationwithacontinuousandstochasticvaryingrefractiveindexbylegendretransformmethod
_version_ 1716748928814153728