Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography

<b>AIM:</b>To investigate peripapillary retinal nerve fiber layer (RNFL), macula and ganglion cell layer thicknesses (GCC) in amblyopic eyes with spectral domain optical coherence tomography (SD-OCT).<b>METHODS:</b>Thirty six patients with a history of unilateral amblyopia an...

Full description

Bibliographic Details
Main Author: Penpe Gul Firat
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2013-02-01
Series:International Journal of Ophthalmology
Subjects:
Online Access:http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3580258/
id doaj-e30700f46e2c4ad8a2303bed775e4025
record_format Article
spelling doaj-e30700f46e2c4ad8a2303bed775e40252020-11-24T22:43:50ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982013-02-0161909410.3980/j.issn.2222-3959.2013.01.19Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomographyPenpe Gul Firat<b>AIM:</b>To investigate peripapillary retinal nerve fiber layer (RNFL), macula and ganglion cell layer thicknesses (GCC) in amblyopic eyes with spectral domain optical coherence tomography (SD-OCT).<b>METHODS:</b>Thirty six patients with a history of unilateral amblyopia and thirty two children who had emmetropia without amblyopia were included in this study.In this institutional study, 36 eyes of 36 patients with amblyopia (AE), 36 fellow eyes without amblyopia (FE), and 32 eyes of 32 normal subjects (NE) were included. RNFL, GCC and macular thickness measurements were performed with RS-3000 OCT Retina Scan (Nidek Inc CA. USA).<b>RESULTS:</b>The mean global thicknesses of the RNFL were 113.22±21.47, 111.57±18.25, 109.96±11.31µm in the AE, FE, and NE, respectively. There was no statistically significant difference for mean global RNFL thickness among the eyes (<i>P</i>=0.13). The mean thicknesses of the macula were 258.25±18.31, 258.75±19.54, 248.62±10.57μm in the AE, FE and NE, respectively. There was no statistically significant difference for thickness of macula among the eyes (<i>P</i>=0.06). The GCC was investigated into two parts:superior and inferior. The mean thicknesses of superior GCC were 102.57±13.32, 103.32±10.64, 100.52±5.88μm in the AE, FE, and NE, respectively. The mean thicknesses of inferior GCC were 103.82±12.60, 107.82±12.33, 105.86±10.79μm in the AE, FE and NE, respectively. There was no statistically significant difference for thickness of superior and inferior GCC between the eyes (<i>P</i>=0.63, <i>P</i>=0.46).<b>CONCLUSION:</b>The macular thicknesses of AE and FEwere greater than the NE, although it was not statistically significant. Amblyopia does not seem to have a profound effect on the RNFL, macula and GCC.http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3580258/amblyopiaretinal nerve fiber layermaculaganglion cell complex
collection DOAJ
language English
format Article
sources DOAJ
author Penpe Gul Firat
spellingShingle Penpe Gul Firat
Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
International Journal of Ophthalmology
amblyopia
retinal nerve fiber layer
macula
ganglion cell complex
author_facet Penpe Gul Firat
author_sort Penpe Gul Firat
title Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
title_short Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
title_full Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
title_fullStr Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
title_full_unstemmed Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
title_sort evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series International Journal of Ophthalmology
issn 2222-3959
2227-4898
publishDate 2013-02-01
description <b>AIM:</b>To investigate peripapillary retinal nerve fiber layer (RNFL), macula and ganglion cell layer thicknesses (GCC) in amblyopic eyes with spectral domain optical coherence tomography (SD-OCT).<b>METHODS:</b>Thirty six patients with a history of unilateral amblyopia and thirty two children who had emmetropia without amblyopia were included in this study.In this institutional study, 36 eyes of 36 patients with amblyopia (AE), 36 fellow eyes without amblyopia (FE), and 32 eyes of 32 normal subjects (NE) were included. RNFL, GCC and macular thickness measurements were performed with RS-3000 OCT Retina Scan (Nidek Inc CA. USA).<b>RESULTS:</b>The mean global thicknesses of the RNFL were 113.22±21.47, 111.57±18.25, 109.96±11.31µm in the AE, FE, and NE, respectively. There was no statistically significant difference for mean global RNFL thickness among the eyes (<i>P</i>=0.13). The mean thicknesses of the macula were 258.25±18.31, 258.75±19.54, 248.62±10.57μm in the AE, FE and NE, respectively. There was no statistically significant difference for thickness of macula among the eyes (<i>P</i>=0.06). The GCC was investigated into two parts:superior and inferior. The mean thicknesses of superior GCC were 102.57±13.32, 103.32±10.64, 100.52±5.88μm in the AE, FE, and NE, respectively. The mean thicknesses of inferior GCC were 103.82±12.60, 107.82±12.33, 105.86±10.79μm in the AE, FE and NE, respectively. There was no statistically significant difference for thickness of superior and inferior GCC between the eyes (<i>P</i>=0.63, <i>P</i>=0.46).<b>CONCLUSION:</b>The macular thicknesses of AE and FEwere greater than the NE, although it was not statistically significant. Amblyopia does not seem to have a profound effect on the RNFL, macula and GCC.
topic amblyopia
retinal nerve fiber layer
macula
ganglion cell complex
url http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3580258/