Summary: | Abstract The study of spray combustion is difficult due to the multiplicity of inter-dependent variables, such as pressure, temperature, droplet size, droplet size distribution, etc, especially industrial cases. Therefore, a combustion vessel developed to study the combustion of droplet clouds from a fundamental point of view has been chosen for the present work. However, it was required a full characterization of the aerosols produced before any combustion study could be undertaken. The distribution of droplets within the mixture, without combustion, was characterised using several laser diagnostics, variables such as Sauter mean diameter, number density, gas and liquid equivalence ratios were determined. Nearly mono-sized droplet clouds were obtained in this vessel and the droplet diameter was a well defined function of time<br>Resumen Estudiar la combustión de atomizados es difícil debido a la multiplicidad de variables interdependientes involucradas, tales como presión, temperatura, tamaño de gotas, distribución del tamaño de gotas, etc., especialmente en equipos industriales. Por ello, se ha seleccionado para el presente estudio un equipo para ensayos fundamentales de la combustión en nubes de gotas. Antes de efectuar un estudio de la combustión es indispensable caracterizar los aerosoles producidos en este equipo. La distribución de gotas dentro de la mezcla sin combustión se caracterizó usando varios diagnósticos con laser y se determinaron variables como diámetro medio Sauter, número densidad y relación de equivalencia gaseosa y de líquido. En este recipiente, se obtuvieron nubes de gotas prácticamente de tamaño único, siendo el tamaño de estas una función del tiempo muy bien definida
|