Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification

The inter-turn short circuit is a common fault in the synchronous generator. This fault is not easily detected at early stage. However, with the development of the fault, it will pose a threat to the safe operation of the generator. To detect the inter-turn short circuit of rotor winding, the feasib...

Full description

Bibliographic Details
Main Authors: Luo Wang, Yonggang Li, Junqing Li
Format: Article
Language:English
Published: MDPI AG 2018-09-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/11/10/2524
id doaj-e2464a401afc40f4836579342349c369
record_format Article
spelling doaj-e2464a401afc40f4836579342349c3692020-11-24T21:46:37ZengMDPI AGEnergies1996-10732018-09-011110252410.3390/en11102524en11102524Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel IdentificationLuo Wang0Yonggang Li1Junqing Li2State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, ChinaThe inter-turn short circuit is a common fault in the synchronous generator. This fault is not easily detected at early stage. However, with the development of the fault, it will pose a threat to the safe operation of the generator. To detect the inter-turn short circuit of rotor winding, the feasibility of identifying the stator branch characteristics of synchronous generator during inter-turn short circuit was analyzed. In this paper, an on-line fault identification method based on Volterra kernel identification is presented. This method uses the stator branch voltage and stator unbalance branch current collected from the generator as input and output signals of the series model. Recursive batch least squares method is applied to calculate the three kernels of Volterra series. When the generator is in normal state or fault state, the Volterra kernel will change accordingly. Through the identification of the time-domain kernel of the nonlinear transfer model, the inter-turn short circuit fault of the synchronous generator is diagnosed. The correctness and effectiveness of this method is verified by using the data of fault experimental synchronous generator.http://www.mdpi.com/1996-1073/11/10/2524synchronous generatorinter-turn short circuitstator unbalance branch currentVolterra seriesfault diagnosis
collection DOAJ
language English
format Article
sources DOAJ
author Luo Wang
Yonggang Li
Junqing Li
spellingShingle Luo Wang
Yonggang Li
Junqing Li
Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
Energies
synchronous generator
inter-turn short circuit
stator unbalance branch current
Volterra series
fault diagnosis
author_facet Luo Wang
Yonggang Li
Junqing Li
author_sort Luo Wang
title Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
title_short Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
title_full Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
title_fullStr Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
title_full_unstemmed Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
title_sort diagnosis of inter-turn short circuit of synchronous generator rotor winding based on volterra kernel identification
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2018-09-01
description The inter-turn short circuit is a common fault in the synchronous generator. This fault is not easily detected at early stage. However, with the development of the fault, it will pose a threat to the safe operation of the generator. To detect the inter-turn short circuit of rotor winding, the feasibility of identifying the stator branch characteristics of synchronous generator during inter-turn short circuit was analyzed. In this paper, an on-line fault identification method based on Volterra kernel identification is presented. This method uses the stator branch voltage and stator unbalance branch current collected from the generator as input and output signals of the series model. Recursive batch least squares method is applied to calculate the three kernels of Volterra series. When the generator is in normal state or fault state, the Volterra kernel will change accordingly. Through the identification of the time-domain kernel of the nonlinear transfer model, the inter-turn short circuit fault of the synchronous generator is diagnosed. The correctness and effectiveness of this method is verified by using the data of fault experimental synchronous generator.
topic synchronous generator
inter-turn short circuit
stator unbalance branch current
Volterra series
fault diagnosis
url http://www.mdpi.com/1996-1073/11/10/2524
work_keys_str_mv AT luowang diagnosisofinterturnshortcircuitofsynchronousgeneratorrotorwindingbasedonvolterrakernelidentification
AT yonggangli diagnosisofinterturnshortcircuitofsynchronousgeneratorrotorwindingbasedonvolterrakernelidentification
AT junqingli diagnosisofinterturnshortcircuitofsynchronousgeneratorrotorwindingbasedonvolterrakernelidentification
_version_ 1725901007497461760