Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic Neuropathy

Objective. To investigate the association of the diameter of the internal carotid artery siphon (ICAS) and nonarteritic anterior ischaemic optic neuropathy (NAION). Methods. Thirty patients clinically diagnosed with NAION (unilateral affected) who presented to Beijing Friendship Hospital from Januar...

Full description

Bibliographic Details
Main Authors: Zhiyong Fu, Hongyang Li, Wei Wang, Yanling Wang
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2019/7910602
id doaj-e23c7003dbc040699a099e13bef49f81
record_format Article
spelling doaj-e23c7003dbc040699a099e13bef49f812020-11-24T20:51:10ZengHindawi LimitedJournal of Ophthalmology2090-004X2090-00582019-01-01201910.1155/2019/79106027910602Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic NeuropathyZhiyong Fu0Hongyang Li1Wei Wang2Yanling Wang3Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, ChinaDepartment of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, ChinaDepartment of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, ChinaDepartment of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, ChinaObjective. To investigate the association of the diameter of the internal carotid artery siphon (ICAS) and nonarteritic anterior ischaemic optic neuropathy (NAION). Methods. Thirty patients clinically diagnosed with NAION (unilateral affected) who presented to Beijing Friendship Hospital from January 2017 to October 2018 were selected. The eyes suffered from NAION were enrolled as the observation group, and the fellow healthy eyes were enrolled as the control group. The following indexes were measured: diameter of the ICAS and the ophthalmic artery (OA), intima-media thickness (IMT) of the internal carotid artery (ICA), degree of stenosis of the ICA and plaque formation, and hemodynamic parameters of the ICA and the short posterior ciliary arteries (SPCAs). All the values were compared between the two groups. Results. The diameter of the ICAS in the observation group (0.30 ± 0.07 cm) significantly narrowed compared with that of the control group (0.32 ± 0.06 cm) (P<0.05), but the diameter of the OA of the two groups had no significant difference. The detection rate of carotid atherosclerosis plaque, the average blood flow velocity (Vm), and the resistance index (RI) of the ICA in the observation group (46.67%, 26.81 ± 1.78 cm/s, and 0.72 ± 0.06) had significant differences compared with those of the control group (16.67%, 28.19 ± 2.75 cm/s, and 0.70 ± 0.05) (P<0.05), but the gradings of ICA stenosis and IMT between the two groups had no significant differences. The peak systolic velocity (PSV) and the end diastolic velocity (EDV) of the SPCAs in the observation group (10.72 ± 2.88 cm/s and 3.43 ± 1.01 cm/s) were significantly lower than those of the control group (13.62 ± 3.93 cm/s and 4.59 ± 1.71 cm/s) (P<0.05), but the RI of the SPCAs of the two groups had no significant differences. Conclusion. The diameter of the ICAS has a close relationship with NAION.http://dx.doi.org/10.1155/2019/7910602
collection DOAJ
language English
format Article
sources DOAJ
author Zhiyong Fu
Hongyang Li
Wei Wang
Yanling Wang
spellingShingle Zhiyong Fu
Hongyang Li
Wei Wang
Yanling Wang
Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic Neuropathy
Journal of Ophthalmology
author_facet Zhiyong Fu
Hongyang Li
Wei Wang
Yanling Wang
author_sort Zhiyong Fu
title Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic Neuropathy
title_short Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic Neuropathy
title_full Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic Neuropathy
title_fullStr Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic Neuropathy
title_full_unstemmed Research on Association of the Diameter of the Internal Carotid Artery Siphon and Nonarteritic Anterior Ischaemic Optic Neuropathy
title_sort research on association of the diameter of the internal carotid artery siphon and nonarteritic anterior ischaemic optic neuropathy
publisher Hindawi Limited
series Journal of Ophthalmology
issn 2090-004X
2090-0058
publishDate 2019-01-01
description Objective. To investigate the association of the diameter of the internal carotid artery siphon (ICAS) and nonarteritic anterior ischaemic optic neuropathy (NAION). Methods. Thirty patients clinically diagnosed with NAION (unilateral affected) who presented to Beijing Friendship Hospital from January 2017 to October 2018 were selected. The eyes suffered from NAION were enrolled as the observation group, and the fellow healthy eyes were enrolled as the control group. The following indexes were measured: diameter of the ICAS and the ophthalmic artery (OA), intima-media thickness (IMT) of the internal carotid artery (ICA), degree of stenosis of the ICA and plaque formation, and hemodynamic parameters of the ICA and the short posterior ciliary arteries (SPCAs). All the values were compared between the two groups. Results. The diameter of the ICAS in the observation group (0.30 ± 0.07 cm) significantly narrowed compared with that of the control group (0.32 ± 0.06 cm) (P<0.05), but the diameter of the OA of the two groups had no significant difference. The detection rate of carotid atherosclerosis plaque, the average blood flow velocity (Vm), and the resistance index (RI) of the ICA in the observation group (46.67%, 26.81 ± 1.78 cm/s, and 0.72 ± 0.06) had significant differences compared with those of the control group (16.67%, 28.19 ± 2.75 cm/s, and 0.70 ± 0.05) (P<0.05), but the gradings of ICA stenosis and IMT between the two groups had no significant differences. The peak systolic velocity (PSV) and the end diastolic velocity (EDV) of the SPCAs in the observation group (10.72 ± 2.88 cm/s and 3.43 ± 1.01 cm/s) were significantly lower than those of the control group (13.62 ± 3.93 cm/s and 4.59 ± 1.71 cm/s) (P<0.05), but the RI of the SPCAs of the two groups had no significant differences. Conclusion. The diameter of the ICAS has a close relationship with NAION.
url http://dx.doi.org/10.1155/2019/7910602
work_keys_str_mv AT zhiyongfu researchonassociationofthediameteroftheinternalcarotidarterysiphonandnonarteriticanteriorischaemicopticneuropathy
AT hongyangli researchonassociationofthediameteroftheinternalcarotidarterysiphonandnonarteriticanteriorischaemicopticneuropathy
AT weiwang researchonassociationofthediameteroftheinternalcarotidarterysiphonandnonarteriticanteriorischaemicopticneuropathy
AT yanlingwang researchonassociationofthediameteroftheinternalcarotidarterysiphonandnonarteriticanteriorischaemicopticneuropathy
_version_ 1716802520672632832