NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-Comparison
The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the National Oceanic and Atmospheric Administration–20 (NOAA-20) and the Suomi National Polar-orbiting Partnership Program (S-NPP) satellites were launched in late 2017 and 2011, respectively. This paper presents a recent update in the V...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-01-01
|
Series: | Remote Sensing |
Subjects: | |
Online Access: | https://www.mdpi.com/2072-4292/13/3/448 |
id |
doaj-e191180b0fac4f92b5e39875ea5d2f28 |
---|---|
record_format |
Article |
spelling |
doaj-e191180b0fac4f92b5e39875ea5d2f282021-01-28T00:06:28ZengMDPI AGRemote Sensing2072-42922021-01-011344844810.3390/rs13030448NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-ComparisonWenhui Wang0Changyong Cao1CISESS/ESSIC, University of Maryland, College Park, MD 20740, USANOAA/NESDIS/Center for Satellite Applications and Research, College Park, MD 20740, USAThe Visible Infrared Imaging Radiometer Suite (VIIRS) on board the National Oceanic and Atmospheric Administration–20 (NOAA-20) and the Suomi National Polar-orbiting Partnership Program (S-NPP) satellites were launched in late 2017 and 2011, respectively. This paper presents a recent update in the VIIRS thermal emissive bands (TEB) on-orbit calibration algorithm and inter-compares long-term instrument and TEB sensor data records (SDR) performances of the two VIIRS, to support user communities. The VIIRS TEB calibration algorithm was improved to mitigate calibration biases during the blackbody warm-up/cool-down (WUCD) events. Four WUCD bias correction methods were implemented in the NOAA operational processing in 2019: (1) the Nominal-F method, (2) the WUCD-C method, (3) the Ltrace method, and (4) the Ltrace-2 method. Our evaluation results indicate that the on-orbit performances of the two VIIRS instruments have been generally stable and comparable with each other, except that NOAA-20 VIIRS blackbody and instrument temperatures are lower than those of the S-NPP VIIRS. The degradations in the S-NPP TEB detector responsivities remain small after 9 years on-orbit. NOAA-20 detector responsivities have been generally stable after the longwave infrared degradation during its early mission was resolved by the mid-mission outgassing. NOAA-20 and S-NPP VIIRS TEB SDRs agree with co-located Cross-track Infrared Sounder observations, with daily averaged biases within 0.1 K at nadir. After the implementation of operational WUCD bias correction, residual TEB WUCD biases are similar for NOAA-20 and S-NPP, with daily averaged biases ~ 0.01K in all bands.https://www.mdpi.com/2072-4292/13/3/448NOAA-20S-NPPVIIRSThermal Emissive Bands (TEB), Sensor Data Record (SDR), operational processing, radiometric calibration, blackbody, warm-up/cool-down (WUCD) bias correction |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Wenhui Wang Changyong Cao |
spellingShingle |
Wenhui Wang Changyong Cao NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-Comparison Remote Sensing NOAA-20 S-NPP VIIRS Thermal Emissive Bands (TEB), Sensor Data Record (SDR), operational processing, radiometric calibration, blackbody, warm-up/cool-down (WUCD) bias correction |
author_facet |
Wenhui Wang Changyong Cao |
author_sort |
Wenhui Wang |
title |
NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-Comparison |
title_short |
NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-Comparison |
title_full |
NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-Comparison |
title_fullStr |
NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-Comparison |
title_full_unstemmed |
NOAA-20 and S-NPP VIIRS Thermal Emissive Bands On-Orbit Calibration Algorithm Update and Long-Term Performance Inter-Comparison |
title_sort |
noaa-20 and s-npp viirs thermal emissive bands on-orbit calibration algorithm update and long-term performance inter-comparison |
publisher |
MDPI AG |
series |
Remote Sensing |
issn |
2072-4292 |
publishDate |
2021-01-01 |
description |
The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the National Oceanic and Atmospheric Administration–20 (NOAA-20) and the Suomi National Polar-orbiting Partnership Program (S-NPP) satellites were launched in late 2017 and 2011, respectively. This paper presents a recent update in the VIIRS thermal emissive bands (TEB) on-orbit calibration algorithm and inter-compares long-term instrument and TEB sensor data records (SDR) performances of the two VIIRS, to support user communities. The VIIRS TEB calibration algorithm was improved to mitigate calibration biases during the blackbody warm-up/cool-down (WUCD) events. Four WUCD bias correction methods were implemented in the NOAA operational processing in 2019: (1) the Nominal-F method, (2) the WUCD-C method, (3) the Ltrace method, and (4) the Ltrace-2 method. Our evaluation results indicate that the on-orbit performances of the two VIIRS instruments have been generally stable and comparable with each other, except that NOAA-20 VIIRS blackbody and instrument temperatures are lower than those of the S-NPP VIIRS. The degradations in the S-NPP TEB detector responsivities remain small after 9 years on-orbit. NOAA-20 detector responsivities have been generally stable after the longwave infrared degradation during its early mission was resolved by the mid-mission outgassing. NOAA-20 and S-NPP VIIRS TEB SDRs agree with co-located Cross-track Infrared Sounder observations, with daily averaged biases within 0.1 K at nadir. After the implementation of operational WUCD bias correction, residual TEB WUCD biases are similar for NOAA-20 and S-NPP, with daily averaged biases ~ 0.01K in all bands. |
topic |
NOAA-20 S-NPP VIIRS Thermal Emissive Bands (TEB), Sensor Data Record (SDR), operational processing, radiometric calibration, blackbody, warm-up/cool-down (WUCD) bias correction |
url |
https://www.mdpi.com/2072-4292/13/3/448 |
work_keys_str_mv |
AT wenhuiwang noaa20andsnppviirsthermalemissivebandsonorbitcalibrationalgorithmupdateandlongtermperformanceintercomparison AT changyongcao noaa20andsnppviirsthermalemissivebandsonorbitcalibrationalgorithmupdateandlongtermperformanceintercomparison |
_version_ |
1724320271187312640 |