Biocompatibility of Intraocular Lenses

The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory a...

Full description

Bibliographic Details
Main Authors: Pelin Özyol, Erhan Özyol, Fatih Karel
Format: Article
Language:English
Published: Galenos Yayinevi 2017-08-01
Series:Türk Oftalmoloji Dergisi
Subjects:
Online Access:http://www.oftalmoloji.org/article_15223/Biocompatibility-Of-Intraocular-Lenses
id doaj-e11e60777c7e4971975ded7492ed46fa
record_format Article
spelling doaj-e11e60777c7e4971975ded7492ed46fa2020-11-24T23:17:15ZengGalenos YayineviTürk Oftalmoloji Dergisi1300-06592147-26612017-08-0147422122510.4274/tjo.10437Biocompatibility of Intraocular LensesPelin Özyol0Erhan Özyol1Fatih Karel2Muğla Sıtkı Koçman University Training and Research Hospital, Department of Ophthalmology, Muğla, TurkeyMuğla Sıtkı Koçman University Training and Research Hospital, Department of Ophthalmology, Muğla, TurkeyDünyagöz Hospital, Ophthalmology Clinic, Ankara, Turkey The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in terms of uveal biocompatibility, based on the inflammatory foreign-body reaction of the eye against the implant, and in terms of capsular biocompatibility, determined by the relationship of the intraocular lens with residual lens epithelial cells within the capsular bag. Insufficient biocompatibility of intraocular lens materials may result in different clinical entities such as anterior capsule opacification, posterior capsule opacification, and lens epithelial cell ongrowth. Intraocular lenses are increasingly implanted much earlier in life in cases such as refractive lens exchange or pediatric intraocular lens implantation after congenital cataract surgery, and these lenses are expected to exhibit maximum performance for many decades. The materials used in intraocular lens manufacture should, therefore, ensure long-term uveal and capsular biocompatibility. In this article, we review the currently available materials used in the manufacture of intraocular lenses, especially with regard to their uveal and capsular biocompatibility, and discuss efforts to improve the biocompatibility of intraocular lenses.http://www.oftalmoloji.org/article_15223/Biocompatibility-Of-Intraocular-LensesUveal biocompatibilitycapsular biocompatibilitycataract surgeryhydrophilic acrylic intraocular lenshydrophobic acrylic intraocular lens
collection DOAJ
language English
format Article
sources DOAJ
author Pelin Özyol
Erhan Özyol
Fatih Karel
spellingShingle Pelin Özyol
Erhan Özyol
Fatih Karel
Biocompatibility of Intraocular Lenses
Türk Oftalmoloji Dergisi
Uveal biocompatibility
capsular biocompatibility
cataract surgery
hydrophilic acrylic intraocular lens
hydrophobic acrylic intraocular lens
author_facet Pelin Özyol
Erhan Özyol
Fatih Karel
author_sort Pelin Özyol
title Biocompatibility of Intraocular Lenses
title_short Biocompatibility of Intraocular Lenses
title_full Biocompatibility of Intraocular Lenses
title_fullStr Biocompatibility of Intraocular Lenses
title_full_unstemmed Biocompatibility of Intraocular Lenses
title_sort biocompatibility of intraocular lenses
publisher Galenos Yayinevi
series Türk Oftalmoloji Dergisi
issn 1300-0659
2147-2661
publishDate 2017-08-01
description The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in terms of uveal biocompatibility, based on the inflammatory foreign-body reaction of the eye against the implant, and in terms of capsular biocompatibility, determined by the relationship of the intraocular lens with residual lens epithelial cells within the capsular bag. Insufficient biocompatibility of intraocular lens materials may result in different clinical entities such as anterior capsule opacification, posterior capsule opacification, and lens epithelial cell ongrowth. Intraocular lenses are increasingly implanted much earlier in life in cases such as refractive lens exchange or pediatric intraocular lens implantation after congenital cataract surgery, and these lenses are expected to exhibit maximum performance for many decades. The materials used in intraocular lens manufacture should, therefore, ensure long-term uveal and capsular biocompatibility. In this article, we review the currently available materials used in the manufacture of intraocular lenses, especially with regard to their uveal and capsular biocompatibility, and discuss efforts to improve the biocompatibility of intraocular lenses.
topic Uveal biocompatibility
capsular biocompatibility
cataract surgery
hydrophilic acrylic intraocular lens
hydrophobic acrylic intraocular lens
url http://www.oftalmoloji.org/article_15223/Biocompatibility-Of-Intraocular-Lenses
work_keys_str_mv AT pelinozyol biocompatibilityofintraocularlenses
AT erhanozyol biocompatibilityofintraocularlenses
AT fatihkarel biocompatibilityofintraocularlenses
_version_ 1725584029944643584