Experimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness
The object of this research study was to investigate the maximum effectiveness values of the energy wheel by experimental tests conducted under extreme difference ambient air conditions parameters, different air volume flow rates, and energy wheel rotation speeds. Air temperature and humidity experi...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
VINCA Institute of Nuclear Sciences
2020-01-01
|
Series: | Thermal Science |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/0354-9836/2020/0354-98361900012K.pdf |
id |
doaj-e110c12c9f2244839b6e1487a099c64f |
---|---|
record_format |
Article |
spelling |
doaj-e110c12c9f2244839b6e1487a099c64f2021-01-02T14:27:07ZengVINCA Institute of Nuclear SciencesThermal Science0354-98362020-01-01243 Part B2113212410.2298/TSCI180927012K0354-98361900012KExperimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectivenessKassai Miklos0Al-Hyari Laith1Budapest University of Technology and Economics, Department of Building Service Engineering and Process Engineering, Budapest, HungaryBudapest University of Technology and Economics, Department of Building Service Engineering and Process Engineering, Budapest, HungaryThe object of this research study was to investigate the maximum effectiveness values of the energy wheel by experimental tests conducted under extreme difference ambient air conditions parameters, different air volume flow rates, and energy wheel rotation speeds. Air temperature and humidity experimental tests were performed using a test facility that was developed and installed into the Indoor Air Quality and Thermal Comfort Laboratory of Budapest University of Technology and Economics. Our objective was to get the effectiveness values of sorption coated air-to-air energy recovery wheel for steady-state conditions under different ambient air (as supply air inlet) conditions. It was found that the sensible effectiveness increases by decreasing the volumetric flow rate through the wheel, and the optimum values of the effectiveness were given at the maximum wheel rotation speed based on the tests. As for the latent and total effectivenesses, their characteristics show an increasing trend by decreasing the air volume flow rate, ambient air temperature and relative humidity and increasing the wheel rotation speed.http://www.doiserbia.nb.rs/img/doi/0354-9836/2020/0354-98361900012K.pdfenergy wheelenergy recoveryair handling uniteffectivenessoperation parameterswheel rotation speed |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Kassai Miklos Al-Hyari Laith |
spellingShingle |
Kassai Miklos Al-Hyari Laith Experimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness Thermal Science energy wheel energy recovery air handling unit effectiveness operation parameters wheel rotation speed |
author_facet |
Kassai Miklos Al-Hyari Laith |
author_sort |
Kassai Miklos |
title |
Experimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness |
title_short |
Experimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness |
title_full |
Experimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness |
title_fullStr |
Experimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness |
title_full_unstemmed |
Experimental investigation on operation parameters of 3Å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness |
title_sort |
experimental investigation on operation parameters of 3å molecular sieve desiccant coated total energy recovery wheel for maximum effectiveness |
publisher |
VINCA Institute of Nuclear Sciences |
series |
Thermal Science |
issn |
0354-9836 |
publishDate |
2020-01-01 |
description |
The object of this research study was to investigate the maximum effectiveness values of the energy wheel by experimental tests conducted under extreme difference ambient air conditions parameters, different air volume flow rates, and energy wheel rotation speeds. Air temperature and humidity experimental tests were performed using a test facility that was developed and installed into the Indoor Air Quality and Thermal Comfort Laboratory of Budapest University of Technology and Economics. Our objective was to get the effectiveness values of sorption coated air-to-air energy recovery wheel for steady-state conditions under different ambient air (as supply air inlet) conditions. It was found that the sensible effectiveness increases by decreasing the volumetric flow rate through the wheel, and the optimum values of the effectiveness were given at the maximum wheel rotation speed based on the tests. As for the latent and total effectivenesses, their characteristics show an increasing trend by decreasing the air volume flow rate, ambient air temperature and relative humidity and increasing the wheel rotation speed. |
topic |
energy wheel energy recovery air handling unit effectiveness operation parameters wheel rotation speed |
url |
http://www.doiserbia.nb.rs/img/doi/0354-9836/2020/0354-98361900012K.pdf |
work_keys_str_mv |
AT kassaimiklos experimentalinvestigationonoperationparametersof3amolecularsievedesiccantcoatedtotalenergyrecoverywheelformaximumeffectiveness AT alhyarilaith experimentalinvestigationonoperationparametersof3amolecularsievedesiccantcoatedtotalenergyrecoverywheelformaximumeffectiveness |
_version_ |
1724353460418117632 |