Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic Bearings

Active magnetic bearings (AMBs) commonly use pulse-width modulation to reduce analogous hardware and manufacturing costs, but they experience sensing process, sensing accuracy and stability problems. To address these issues, a synchronous sampling-based direct current estimation (SS-DCE) method is p...

Full description

Bibliographic Details
Main Authors: Xiongxin Hu, Fang Xu, Ronghui Wang, Dapeng Tan
Format: Article
Language:English
Published: MDPI AG 2020-06-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/12/3497
id doaj-e0c292140eb942e690b007882809a934
record_format Article
spelling doaj-e0c292140eb942e690b007882809a9342020-11-25T03:14:47ZengMDPI AGSensors1424-82202020-06-01203497349710.3390/s20123497Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic BearingsXiongxin Hu0Fang Xu1Ronghui Wang2Dapeng Tan3College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, ChinaCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, ChinaCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, ChinaCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, ChinaActive magnetic bearings (AMBs) commonly use pulse-width modulation to reduce analogous hardware and manufacturing costs, but they experience sensing process, sensing accuracy and stability problems. To address these issues, a synchronous sampling-based direct current estimation (SS-DCE) method is proposed herein with a bistate switching power amplifier. First—considering the reluctance evolution mechanism of AMBs—a coupling relation mathematical model between rotor displacement and voltage/current is presented to acquire the rotor position from the working coil current alone. Then—assuming that the switching current was an approximately triangular signal—a DCE for the rotor position was established based on the estimation inductance of the charging/discharging phase. Finally—to decrease the phase shift caused by the self-sensing filters and position estimation algorithms—the SS-DCE method was introduced to conduct precise position detection for rotors with high velocities. The simulation and experimental results indicated that the proposed method could improve the sensing accuracy and stability. Compared to other AMB position estimation methods, the simple linearity of the SS-DCE method was greatly improved and could be controlled below 4%. Evaluation using frequency response analysis showed that the SS-DCE method had excellent dynamic accuracy and could perform at a higher phase margin, especially for the uprising/landing transient state. Moreover, there was a phase margin of 158° at the natural frequency of 19.26 HZ, and the peak sensitivity in the 50–250 μm range reached 10.7 dB.https://www.mdpi.com/1424-8220/20/12/3497self-sensingactive magnetic bearingsleast square methoddirect current estimatorsynchronous sampling
collection DOAJ
language English
format Article
sources DOAJ
author Xiongxin Hu
Fang Xu
Ronghui Wang
Dapeng Tan
spellingShingle Xiongxin Hu
Fang Xu
Ronghui Wang
Dapeng Tan
Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic Bearings
Sensors
self-sensing
active magnetic bearings
least square method
direct current estimator
synchronous sampling
author_facet Xiongxin Hu
Fang Xu
Ronghui Wang
Dapeng Tan
author_sort Xiongxin Hu
title Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic Bearings
title_short Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic Bearings
title_full Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic Bearings
title_fullStr Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic Bearings
title_full_unstemmed Synchronous Sampling-Based Direct Current Estimation Method for Self-Sensing Active Magnetic Bearings
title_sort synchronous sampling-based direct current estimation method for self-sensing active magnetic bearings
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2020-06-01
description Active magnetic bearings (AMBs) commonly use pulse-width modulation to reduce analogous hardware and manufacturing costs, but they experience sensing process, sensing accuracy and stability problems. To address these issues, a synchronous sampling-based direct current estimation (SS-DCE) method is proposed herein with a bistate switching power amplifier. First—considering the reluctance evolution mechanism of AMBs—a coupling relation mathematical model between rotor displacement and voltage/current is presented to acquire the rotor position from the working coil current alone. Then—assuming that the switching current was an approximately triangular signal—a DCE for the rotor position was established based on the estimation inductance of the charging/discharging phase. Finally—to decrease the phase shift caused by the self-sensing filters and position estimation algorithms—the SS-DCE method was introduced to conduct precise position detection for rotors with high velocities. The simulation and experimental results indicated that the proposed method could improve the sensing accuracy and stability. Compared to other AMB position estimation methods, the simple linearity of the SS-DCE method was greatly improved and could be controlled below 4%. Evaluation using frequency response analysis showed that the SS-DCE method had excellent dynamic accuracy and could perform at a higher phase margin, especially for the uprising/landing transient state. Moreover, there was a phase margin of 158° at the natural frequency of 19.26 HZ, and the peak sensitivity in the 50–250 μm range reached 10.7 dB.
topic self-sensing
active magnetic bearings
least square method
direct current estimator
synchronous sampling
url https://www.mdpi.com/1424-8220/20/12/3497
work_keys_str_mv AT xiongxinhu synchronoussamplingbaseddirectcurrentestimationmethodforselfsensingactivemagneticbearings
AT fangxu synchronoussamplingbaseddirectcurrentestimationmethodforselfsensingactivemagneticbearings
AT ronghuiwang synchronoussamplingbaseddirectcurrentestimationmethodforselfsensingactivemagneticbearings
AT dapengtan synchronoussamplingbaseddirectcurrentestimationmethodforselfsensingactivemagneticbearings
_version_ 1724642482705137664