Optimization Method for Voltage Sag Monitor Placement in Power System

Voltage sag is one off the severe power quality issues and may cause huge losses to industries. Voltage sag happens frequently and might be caused by random and unpredictable factors. To monitor voltage sag, Voltage Sag Monitoring (VSM) system has been currently implemented to the whole power syste...

Full description

Bibliographic Details
Main Authors: R. Ismail, D. M. Said, N. Ahmad, M. P. Abdullah, M. Y. Hassan, A. O. Idris
Format: Article
Language:English
Published: Penerbit Universiti Teknikal Malaysia Melaka 2018-04-01
Series:International Journal of Electrical Engineering and Applied Sciences
Online Access:https://ijeeas.utem.edu.my/ijeeas/article/view/3910
id doaj-e09cfcc18e7448fa9c2359f8a8f344af
record_format Article
spelling doaj-e09cfcc18e7448fa9c2359f8a8f344af2021-05-11T02:09:53ZengPenerbit Universiti Teknikal Malaysia MelakaInternational Journal of Electrical Engineering and Applied Sciences2600-74952600-96332018-04-0111Optimization Method for Voltage Sag Monitor Placement in Power SystemR. IsmailD. M. SaidN. AhmadM. P. AbdullahM. Y. HassanA. O. Idris Voltage sag is one off the severe power quality issues and may cause huge losses to industries. Voltage sag happens frequently and might be caused by random and unpredictable factors. To monitor voltage sag, Voltage Sag Monitoring (VSM) system has been currently implemented to the whole power system. However, implementation of VSM at all buses is not economical. Therefore, the objective of this study is to evaluate the optimal number and placement of voltage sag monitors in IEEE 30-bus system. First, the concept of monitor reach area is used. In this study, voltage sag is represented by balance and unbalance fault with fault impedance, Zf equal to 0Ω. To obtain fault voltage on each bus, IEEE 30-bus system was constructed using PowerWorld software. Then, monitor reach area matrix is formed by comparing fault voltage with selected voltage threshold, α. After that, monitor reach area is analysed by using branch and bound method to evaluate the minimum number and the possible arrangements of VSM. Finally, to optimally place the identified number of VSM, all possible combinations of VSM in the power system were evaluated using sag severity index. To show the effectiveness of the proposed method on the optimal voltage sag monitor placement in power system, the proposed algorithm was implemented and tested on the IEEE 30-bus test system. The proposed method was tested with two different α; i.e. 0.55 p.u. and 0.80 p.u. respectively. The proposed method successfully found the optimal number and its placement for monitoring the whole IEEE 30-bus system with respective α value. Based on the results, for α equal to 0.55, VSM need to be installed on bus 6, 17, 25 and 30 in order to monitor voltage sag on IEEE 30-bus system; and for α equal to 0.80 p.u., VSM are only required to be placed at bus 25 respectively. https://ijeeas.utem.edu.my/ijeeas/article/view/3910
collection DOAJ
language English
format Article
sources DOAJ
author R. Ismail
D. M. Said
N. Ahmad
M. P. Abdullah
M. Y. Hassan
A. O. Idris
spellingShingle R. Ismail
D. M. Said
N. Ahmad
M. P. Abdullah
M. Y. Hassan
A. O. Idris
Optimization Method for Voltage Sag Monitor Placement in Power System
International Journal of Electrical Engineering and Applied Sciences
author_facet R. Ismail
D. M. Said
N. Ahmad
M. P. Abdullah
M. Y. Hassan
A. O. Idris
author_sort R. Ismail
title Optimization Method for Voltage Sag Monitor Placement in Power System
title_short Optimization Method for Voltage Sag Monitor Placement in Power System
title_full Optimization Method for Voltage Sag Monitor Placement in Power System
title_fullStr Optimization Method for Voltage Sag Monitor Placement in Power System
title_full_unstemmed Optimization Method for Voltage Sag Monitor Placement in Power System
title_sort optimization method for voltage sag monitor placement in power system
publisher Penerbit Universiti Teknikal Malaysia Melaka
series International Journal of Electrical Engineering and Applied Sciences
issn 2600-7495
2600-9633
publishDate 2018-04-01
description Voltage sag is one off the severe power quality issues and may cause huge losses to industries. Voltage sag happens frequently and might be caused by random and unpredictable factors. To monitor voltage sag, Voltage Sag Monitoring (VSM) system has been currently implemented to the whole power system. However, implementation of VSM at all buses is not economical. Therefore, the objective of this study is to evaluate the optimal number and placement of voltage sag monitors in IEEE 30-bus system. First, the concept of monitor reach area is used. In this study, voltage sag is represented by balance and unbalance fault with fault impedance, Zf equal to 0Ω. To obtain fault voltage on each bus, IEEE 30-bus system was constructed using PowerWorld software. Then, monitor reach area matrix is formed by comparing fault voltage with selected voltage threshold, α. After that, monitor reach area is analysed by using branch and bound method to evaluate the minimum number and the possible arrangements of VSM. Finally, to optimally place the identified number of VSM, all possible combinations of VSM in the power system were evaluated using sag severity index. To show the effectiveness of the proposed method on the optimal voltage sag monitor placement in power system, the proposed algorithm was implemented and tested on the IEEE 30-bus test system. The proposed method was tested with two different α; i.e. 0.55 p.u. and 0.80 p.u. respectively. The proposed method successfully found the optimal number and its placement for monitoring the whole IEEE 30-bus system with respective α value. Based on the results, for α equal to 0.55, VSM need to be installed on bus 6, 17, 25 and 30 in order to monitor voltage sag on IEEE 30-bus system; and for α equal to 0.80 p.u., VSM are only required to be placed at bus 25 respectively.
url https://ijeeas.utem.edu.my/ijeeas/article/view/3910
work_keys_str_mv AT rismail optimizationmethodforvoltagesagmonitorplacementinpowersystem
AT dmsaid optimizationmethodforvoltagesagmonitorplacementinpowersystem
AT nahmad optimizationmethodforvoltagesagmonitorplacementinpowersystem
AT mpabdullah optimizationmethodforvoltagesagmonitorplacementinpowersystem
AT myhassan optimizationmethodforvoltagesagmonitorplacementinpowersystem
AT aoidris optimizationmethodforvoltagesagmonitorplacementinpowersystem
_version_ 1721453090596454400