Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study

Aim: The aim of this study is to evaluate the efficacy of new material ultraviolet (UV) light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin (Polymethylmethacrylate (PMMA)) to cobalt-chromium (Co-Cr) retentive minor connector. Setting and Design: Compar...

Full description

Bibliographic Details
Main Authors: Minal Sanjay Kumthekar, Shivsagar Tewary, Pronob Kumar Sanyal
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:The Journal of Indian Prosthodontic Society
Subjects:
Online Access:http://www.j-ips.org/article.asp?issn=0972-4052;year=2020;volume=20;issue=4;spage=394;epage=401;aulast=
id doaj-e0630988e8d64a70afa1a4791bf98b12
record_format Article
spelling doaj-e0630988e8d64a70afa1a4791bf98b122020-11-25T04:02:35ZengWolters Kluwer Medknow PublicationsThe Journal of Indian Prosthodontic Society0972-40521998-40572020-01-0120439440110.4103/jips.jips_85_20Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro studyMinal Sanjay KumthekarShivsagar TewaryPronob Kumar SanyalAim: The aim of this study is to evaluate the efficacy of new material ultraviolet (UV) light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin (Polymethylmethacrylate (PMMA)) to cobalt-chromium (Co-Cr) retentive minor connector. Setting and Design: Comparative evaluation- In-vitro study. Materials and Methods: Sixty samples of Co-Cr plates mimicking minor connectors were fabricated. Thirty samples were coated with new material UV light polymerized clear adhesive and cured under UV light source for 10 min. In gun-metal flask, metal plates were placed in the lower compartment over it. Heat cure acrylic resin was packed in the dough stage with the help of clamps and processed according to the manufacturer's instructions. Samples were kept in artificial saliva for 90 days. Shear and tensile bond strengths were calculated of each sample with a Universal testing machine, and results were statistically analyzed. Type of bond failure was observed for each sample under stereomicroscope. Statistical Analysis Used: Unpaired t test. Results: Tensile bond strength, as well as shear bond strength, showed that 0.93 N and 1.64 N respectively for without application of new adhesive was more as compared to that of samples with the application of new adhesive which is 0.75 N and 1.54 N respectively. Bond failure was found to be an adhesive failure in resin–metal interface. Conclusions: Excellent bonding seen between the new adhesive and acrylic interface but limited effect on the metal interface. To increase bond strength between metal and resin interface, some surface treatment with the metal surface is needed to increase the bonding of the new adhesive to the metal surface.http://www.j-ips.org/article.asp?issn=0972-4052;year=2020;volume=20;issue=4;spage=394;epage=401;aulast=acresin a250 ultravioletadhesivebond failurecast partial denturepmmaultraviolet light cure
collection DOAJ
language English
format Article
sources DOAJ
author Minal Sanjay Kumthekar
Shivsagar Tewary
Pronob Kumar Sanyal
spellingShingle Minal Sanjay Kumthekar
Shivsagar Tewary
Pronob Kumar Sanyal
Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
The Journal of Indian Prosthodontic Society
acresin a250 ultraviolet
adhesive
bond failure
cast partial denture
pmma
ultraviolet light cure
author_facet Minal Sanjay Kumthekar
Shivsagar Tewary
Pronob Kumar Sanyal
author_sort Minal Sanjay Kumthekar
title Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_short Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_full Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_fullStr Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_full_unstemmed Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_sort evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: an in vitro study
publisher Wolters Kluwer Medknow Publications
series The Journal of Indian Prosthodontic Society
issn 0972-4052
1998-4057
publishDate 2020-01-01
description Aim: The aim of this study is to evaluate the efficacy of new material ultraviolet (UV) light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin (Polymethylmethacrylate (PMMA)) to cobalt-chromium (Co-Cr) retentive minor connector. Setting and Design: Comparative evaluation- In-vitro study. Materials and Methods: Sixty samples of Co-Cr plates mimicking minor connectors were fabricated. Thirty samples were coated with new material UV light polymerized clear adhesive and cured under UV light source for 10 min. In gun-metal flask, metal plates were placed in the lower compartment over it. Heat cure acrylic resin was packed in the dough stage with the help of clamps and processed according to the manufacturer's instructions. Samples were kept in artificial saliva for 90 days. Shear and tensile bond strengths were calculated of each sample with a Universal testing machine, and results were statistically analyzed. Type of bond failure was observed for each sample under stereomicroscope. Statistical Analysis Used: Unpaired t test. Results: Tensile bond strength, as well as shear bond strength, showed that 0.93 N and 1.64 N respectively for without application of new adhesive was more as compared to that of samples with the application of new adhesive which is 0.75 N and 1.54 N respectively. Bond failure was found to be an adhesive failure in resin–metal interface. Conclusions: Excellent bonding seen between the new adhesive and acrylic interface but limited effect on the metal interface. To increase bond strength between metal and resin interface, some surface treatment with the metal surface is needed to increase the bonding of the new adhesive to the metal surface.
topic acresin a250 ultraviolet
adhesive
bond failure
cast partial denture
pmma
ultraviolet light cure
url http://www.j-ips.org/article.asp?issn=0972-4052;year=2020;volume=20;issue=4;spage=394;epage=401;aulast=
work_keys_str_mv AT minalsanjaykumthekar evaluationoftheeffectofultravioletlightpolymerizedclearadhesiveonshearandtensilebondstrengthofheatcuredenturebaseresintothecobaltchromiumretentiveminorconnectoraninvitrostudy
AT shivsagartewary evaluationoftheeffectofultravioletlightpolymerizedclearadhesiveonshearandtensilebondstrengthofheatcuredenturebaseresintothecobaltchromiumretentiveminorconnectoraninvitrostudy
AT pronobkumarsanyal evaluationoftheeffectofultravioletlightpolymerizedclearadhesiveonshearandtensilebondstrengthofheatcuredenturebaseresintothecobaltchromiumretentiveminorconnectoraninvitrostudy
_version_ 1724443030110339072