Fatigue and Vibration Parameters Improvement of Steel DIN 41Cr4 by Ultrasonic Shock Peening Treatment

The effects of the ultrasonic peening treatment (UPT) on the rotating bending fatigue behavior and the behavior of the vibrations of alloy steel DIN 41Cr4 were studied. Hardness test, Tensile test, Constant amplitude fatigue tests, and the vibrations measurements have been carried out on the specime...

Full description

Bibliographic Details
Main Authors: Zeina Shaker Mahmood, Jumaa Salman Chiad
Format: Article
Language:English
Published: Al-Nahrain Journal for Engineering Sciences 2019-10-01
Series:مجلة النهرين للعلوم الهندسية
Subjects:
Online Access:https://nahje.com/index.php/main/article/view/692
Description
Summary:The effects of the ultrasonic peening treatment (UPT) on the rotating bending fatigue behavior and the behavior of the vibrations of alloy steel DIN 41Cr4 were studied. Hardness test, Tensile test, Constant amplitude fatigue tests, and the vibrations measurements have been carried out on the specimens. Also, the fracture surface was examined and analyzed by a Scanning Electron Microscope (SEM). The results of the investigations, e.g. stress to number of cycles to failure (S-N) curves, fatigue strength improvement factor was 7%. The decreasing percentage of maximum Fast Fourier Transform (FFT) acceleration of the ultrasonic peened condition compared to the untreated conditions was 45%.