DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHOD
Research with self potential method has been done in Cangar area of Arjuno-Welirang volcano complex, East Java. The purpose of this study was determined the direction of hot fluid flow. This hot fluid forms a geothermal manifestation of hot springs. Data acquisition has been done using fixed electr...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Negeri Surabaya
2017-12-01
|
Series: | Jurnal Penelitian Fisika dan Aplikasinya |
Subjects: | |
Online Access: | https://journal.unesa.ac.id/index.php/jpfa/article/view/1735 |
id |
doaj-e0071c37b6df4485a8e15332c8748d35 |
---|---|
record_format |
Article |
spelling |
doaj-e0071c37b6df4485a8e15332c8748d352020-11-24T23:31:16ZengUniversitas Negeri SurabayaJurnal Penelitian Fisika dan Aplikasinya2087-99462477-17752017-12-017212313210.26740/jpfa.v7n2.p123-1321371DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHODDafiqiy Ya'lu Ulin Nuha0Sukir Maryanto1Didik Rahardi Santoso2Program Pascasarjana Fisika, Fakultas Matematika dan IPA, Universitas BrawijayaJurusan Fisika, Fakultas Matematika dan IPA, Universitas Brawijaya Pusat Studi Energi dan Sumber Daya Alam, Fakultas Matematika dan IPA, Universitas Brawijaya Lab. Measurement and Circuits, Fakultas Matematika dan IPA, Universitas BrawijayaJurusan Fisika, Fakultas Matematika dan IPA, Universitas Brawijaya Pusat Studi Energi dan Sumber Daya Alam, Fakultas Matematika dan IPA, Universitas Brawijaya Lab. Measurement and Circuits, Fakultas Matematika dan IPA, Universitas BrawijayaResearch with self potential method has been done in Cangar area of Arjuno-Welirang volcano complex, East Java. The purpose of this study was determined the direction of hot fluid flow. This hot fluid forms a geothermal manifestation of hot springs. Data acquisition has been done using fixed electrode configuration with interval 5 meters in 5 lines. In this configuration there are two porous pot electrodes, one of them set in fixed station and the other as mobile station. Based on the potential distribution value of the isopotential map, the lowest potential value about -54,5 mV and the highest value about 89,4 mV, so that in Cangar area can predicted the direction of hot fluid flow from southeast to northwest. Based on the results of this research in the direction of hot fluid flow can provide information about hydrothermal system in Cangar area for study of geothermal potential of Arjuno-Welirang Volcano complex, East Javahttps://journal.unesa.ac.id/index.php/jpfa/article/view/1735self potentialfixed base configurationisopotential mapfluid flow |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dafiqiy Ya'lu Ulin Nuha Sukir Maryanto Didik Rahardi Santoso |
spellingShingle |
Dafiqiy Ya'lu Ulin Nuha Sukir Maryanto Didik Rahardi Santoso DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHOD Jurnal Penelitian Fisika dan Aplikasinya self potential fixed base configuration isopotential map fluid flow |
author_facet |
Dafiqiy Ya'lu Ulin Nuha Sukir Maryanto Didik Rahardi Santoso |
author_sort |
Dafiqiy Ya'lu Ulin Nuha |
title |
DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHOD |
title_short |
DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHOD |
title_full |
DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHOD |
title_fullStr |
DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHOD |
title_full_unstemmed |
DETERMINATION OF THE DIRECTION OF HOT FLUID FLOW IN CANGAR AREA, ARJUNO-WELIRANG VOLCANO COMPLEX, EAST JAVA USING SELF POTENTIAL METHOD |
title_sort |
determination of the direction of hot fluid flow in cangar area, arjuno-welirang volcano complex, east java using self potential method |
publisher |
Universitas Negeri Surabaya |
series |
Jurnal Penelitian Fisika dan Aplikasinya |
issn |
2087-9946 2477-1775 |
publishDate |
2017-12-01 |
description |
Research with self potential method has been done in Cangar area of Arjuno-Welirang volcano complex, East Java. The purpose of this study was determined the direction of hot fluid flow. This hot fluid forms a geothermal manifestation of hot springs. Data acquisition has been done using fixed electrode configuration with interval 5 meters in 5 lines. In this configuration there are two porous pot electrodes, one of them set in fixed station and the other as mobile station. Based on the potential distribution value of the isopotential map, the lowest potential value about -54,5 mV and the highest value about 89,4 mV, so that in Cangar area can predicted the direction of hot fluid flow from southeast to northwest. Based on the results of this research in the direction of hot fluid flow can provide information about hydrothermal system in Cangar area for study of geothermal potential of Arjuno-Welirang Volcano complex, East Java |
topic |
self potential fixed base configuration isopotential map fluid flow |
url |
https://journal.unesa.ac.id/index.php/jpfa/article/view/1735 |
work_keys_str_mv |
AT dafiqiyyaluulinnuha determinationofthedirectionofhotfluidflowincangarareaarjunowelirangvolcanocomplexeastjavausingselfpotentialmethod AT sukirmaryanto determinationofthedirectionofhotfluidflowincangarareaarjunowelirangvolcanocomplexeastjavausingselfpotentialmethod AT didikrahardisantoso determinationofthedirectionofhotfluidflowincangarareaarjunowelirangvolcanocomplexeastjavausingselfpotentialmethod |
_version_ |
1725538724574396416 |