HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLES

As a result of the steel cable security rating, it is essential to determine that the nature, value, and quantity of defects will not exceed the critical reject limits while in operation. The high-temperature impact results in uneven wire heating in the cable operation activity. It leads to the cabl...

Full description

Bibliographic Details
Main Authors: Marat Nurmukhamedovich Khalfin, Anatoly Arkadyevich Korotkiy
Format: Article
Language:Russian
Published: Don State Technical University 2013-03-01
Series:Advanced Engineering Research
Subjects:
Online Access:https://www.vestnik-donstu.ru/jour/article/view/382
id doaj-df61c8e01a8c42cb88558d34e102e736
record_format Article
spelling doaj-df61c8e01a8c42cb88558d34e102e7362021-10-02T16:21:19ZrusDon State Technical UniversityAdvanced Engineering Research2687-16532013-03-01131-2112117375HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLESMarat Nurmukhamedovich Khalfin0Anatoly Arkadyevich Korotkiy1South-Russian State Technical University RussiaDon State Technical University. RussiaAs a result of the steel cable security rating, it is essential to determine that the nature, value, and quantity of defects will not exceed the critical reject limits while in operation. The high-temperature impact results in uneven wire heating in the cable operation activity. It leads to the cable deflected mode change, and, consequently, the accident risk grows. On the increase of heating temperature to 370 °С, steel cables need to be rejected, even without waviness in them. The risk of rope break is dramatized by the fact that the steel cable technology, including those with the mechanical core, admits irregularities (various strand length). While in operation, short strands are overloaded, and the long ones are underloaded which results in the waviness origination. For higher safety of the lift cables under the high-temperature conditions (at temperatures above 370 °С), the algorithm considering the degradation risk in the steel cable, and special cable structures with indicator wires are offered for application.https://www.vestnik-donstu.ru/jour/article/view/382lift cablehigh-temperature effectriskexploitationrejection indicesrejection ratessafety assessmentdeflected mode.
collection DOAJ
language Russian
format Article
sources DOAJ
author Marat Nurmukhamedovich Khalfin
Anatoly Arkadyevich Korotkiy
spellingShingle Marat Nurmukhamedovich Khalfin
Anatoly Arkadyevich Korotkiy
HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLES
Advanced Engineering Research
lift cable
high-temperature effect
risk
exploitation
rejection indices
rejection rates
safety assessment
deflected mode.
author_facet Marat Nurmukhamedovich Khalfin
Anatoly Arkadyevich Korotkiy
author_sort Marat Nurmukhamedovich Khalfin
title HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLES
title_short HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLES
title_full HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLES
title_fullStr HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLES
title_full_unstemmed HIGH-TEMPERATURE EFFECT ON OPERATION RISK OF LIFT CABLES
title_sort high-temperature effect on operation risk of lift cables
publisher Don State Technical University
series Advanced Engineering Research
issn 2687-1653
publishDate 2013-03-01
description As a result of the steel cable security rating, it is essential to determine that the nature, value, and quantity of defects will not exceed the critical reject limits while in operation. The high-temperature impact results in uneven wire heating in the cable operation activity. It leads to the cable deflected mode change, and, consequently, the accident risk grows. On the increase of heating temperature to 370 °С, steel cables need to be rejected, even without waviness in them. The risk of rope break is dramatized by the fact that the steel cable technology, including those with the mechanical core, admits irregularities (various strand length). While in operation, short strands are overloaded, and the long ones are underloaded which results in the waviness origination. For higher safety of the lift cables under the high-temperature conditions (at temperatures above 370 °С), the algorithm considering the degradation risk in the steel cable, and special cable structures with indicator wires are offered for application.
topic lift cable
high-temperature effect
risk
exploitation
rejection indices
rejection rates
safety assessment
deflected mode.
url https://www.vestnik-donstu.ru/jour/article/view/382
work_keys_str_mv AT maratnurmukhamedovichkhalfin hightemperatureeffectonoperationriskofliftcables
AT anatolyarkadyevichkorotkiy hightemperatureeffectonoperationriskofliftcables
_version_ 1716852690903891968