Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall

Bibliographic Details
Main Authors: Tyler P. Rasmussen, MD, PhD, Gary Goldsmith, RT, Firas Zahr, MD, Jay K. Bhama, MD, Prashant D. Bhave, MD, FHRS
Format: Article
Language:English
Published: Elsevier 2016-11-01
Series:HeartRhythm Case Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S221402711630080X
id doaj-debed2e680ac4ce684995d3d78bff254
record_format Article
spelling doaj-debed2e680ac4ce684995d3d78bff2542021-07-02T09:17:30ZengElsevierHeartRhythm Case Reports2214-02712016-11-012651151310.1016/j.hrcr.2016.08.003Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wallTyler P. Rasmussen, MD, PhD0Gary Goldsmith, RT1Firas Zahr, MD2Jay K. Bhama, MD3Prashant D. Bhave, MD, FHRS4Department of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, IowaDivision of Cardiovascular Medicine, Department of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, IowaDivision of Cardiovascular Medicine, Department of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, IowaDivision of Cardiothoracic Surgery, Department of General Surgery, University of Iowa Carver College of Medicine, Iowa City, IowaDivision of Cardiovascular Medicine, Department of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, Iowahttp://www.sciencedirect.com/science/article/pii/S221402711630080XCatheterLead extractionPulmonary arterySnare deviceMechanical cutting device
collection DOAJ
language English
format Article
sources DOAJ
author Tyler P. Rasmussen, MD, PhD
Gary Goldsmith, RT
Firas Zahr, MD
Jay K. Bhama, MD
Prashant D. Bhave, MD, FHRS
spellingShingle Tyler P. Rasmussen, MD, PhD
Gary Goldsmith, RT
Firas Zahr, MD
Jay K. Bhama, MD
Prashant D. Bhave, MD, FHRS
Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall
HeartRhythm Case Reports
Catheter
Lead extraction
Pulmonary artery
Snare device
Mechanical cutting device
author_facet Tyler P. Rasmussen, MD, PhD
Gary Goldsmith, RT
Firas Zahr, MD
Jay K. Bhama, MD
Prashant D. Bhave, MD, FHRS
author_sort Tyler P. Rasmussen, MD, PhD
title Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall
title_short Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall
title_full Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall
title_fullStr Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall
title_full_unstemmed Percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall
title_sort percutaneous extraction of a pulmonary artery catheter inadvertently sewn to the right atrial wall
publisher Elsevier
series HeartRhythm Case Reports
issn 2214-0271
publishDate 2016-11-01
topic Catheter
Lead extraction
Pulmonary artery
Snare device
Mechanical cutting device
url http://www.sciencedirect.com/science/article/pii/S221402711630080X
work_keys_str_mv AT tylerprasmussenmdphd percutaneousextractionofapulmonaryarterycatheterinadvertentlysewntotherightatrialwall
AT garygoldsmithrt percutaneousextractionofapulmonaryarterycatheterinadvertentlysewntotherightatrialwall
AT firaszahrmd percutaneousextractionofapulmonaryarterycatheterinadvertentlysewntotherightatrialwall
AT jaykbhamamd percutaneousextractionofapulmonaryarterycatheterinadvertentlysewntotherightatrialwall
AT prashantdbhavemdfhrs percutaneousextractionofapulmonaryarterycatheterinadvertentlysewntotherightatrialwall
_version_ 1721333350675775488