Minimum accelerometer wear-time for reliable estimates of physical activity and sedentary behaviour of people receiving haemodialysis

Abstract Background Low levels of physical activity are implicated in low life expectancies of people receiving maintenance haemodialysis. Accelerometers are increasingly being used to quantify activity behaviours of this population but guidance to quality-assure such data is lacking. The objective...

Full description

Bibliographic Details
Main Authors: Sean Prescott, Jamie P. Traynor, Ilona Shilliday, Tobia Zanotto, Robert Rush, Thomas H. Mercer
Format: Article
Language:English
Published: BMC 2020-06-01
Series:BMC Nephrology
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12882-020-01877-8
Description
Summary:Abstract Background Low levels of physical activity are implicated in low life expectancies of people receiving maintenance haemodialysis. Accelerometers are increasingly being used to quantify activity behaviours of this population but guidance to quality-assure such data is lacking. The objective of this study was to provide data processing and reduction recommendations to ensure accelerometer-derived outcomes are sufficiently reliable for interpretative analysis. Methods Seventy people receiving maintenance haemodialysis (age 55.9 ± 15.7 years, 34% women, 23% diabetic) from a single outpatient renal unit volunteered for the study. Participants wore Actigraph GT3x and ActivPAL monitors during waking hours over seven days. Reliability of accelerometer output (normalised to wear-time) was assessed via intraclass correlation coefficient (ICC). The Spearman-Brown prophecy formula was subsequently applied to the ICCs to derive the minimum required accelerometer wear-time for each behavioural outcome. Results Monitor wear compliance was greater on dialysis compared to non-dialysis days (90% v 77%). Participants were significantly more active on non-dialysis days compared to dialysis days but there were no significant differences in estimated behaviours between days within the same condition. Average measure ICCs for all accelerometer outcomes were high (range 0.76–0.96). Computations indicated that habitual physical activity and sedentary behaviour could be estimated with a minimum reliability level of 0.80 from one dialysis day and two non-dialysis days, and at least eight hours monitor wear per day. Applying this rubric allowed 90% of participant data to be retained for further analysis. Conclusions Regardless of accelerometer, one dialysis and two non-dialysis days data with a minimum of eight hours wear each day should enable habitual activity of people receiving maintenance haemodialysis to be characterised with acceptable reliability. These recommendations reconcile the tension between wear-time criteria stringency and retention of an adequately representative sample.
ISSN:1471-2369