New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.

Background. Optical Spectroscopic techniques widely used in practice despite the high sensitivity and wide range of studied chemical elements have the drawbacks, such as sample preparation, which is possible only in case of destruction of the investigated object. Non-destructive method to investigat...

Full description

Bibliographic Details
Main Authors: V. D. Mishalov, O. V. Michailenko
Format: Article
Language:Russian
Published: Ministry of Health of Ukraine. Dnipropetrovsk Medical Academy 2016-09-01
Series:Морфологія
Subjects:
Online Access:http://morphology.dma.dp.ua/article/view/139600
id doaj-dda11cbba25e46cb9cc2f9e90f45db01
record_format Article
spelling doaj-dda11cbba25e46cb9cc2f9e90f45db012020-11-24T22:59:03ZrusMinistry of Health of Ukraine. Dnipropetrovsk Medical Academy Морфологія1997-96652016-09-0110337337610.26641/1997-9665.2016.3.373-376139600New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.V. D. Mishalov0O. V. Michailenko1Національна медична академія післядипломної освіти імені П.Л. ШупикаКиївське міське клінічне бюро судово-медичної експертизи, КиївBackground. Optical Spectroscopic techniques widely used in practice despite the high sensitivity and wide range of studied chemical elements have the drawbacks, such as sample preparation, which is possible only in case of destruction of the investigated object. Non-destructive method to investigate the elemental composition of metal layers and other products of the shot is X-ray fluorescence spectral analysis, but the knowledge about the possibilities of modern equipment is incomplete. Objective. Identify chemical elements in damage simulator clothes at experimental shots from firearms through X-ray fluorescence spectral element analysis using a spectrometer «M4 TORNADO» manufactured by Bruker. Methods. The object of study was damaged clothe (patches of leather of jacket). Micro X-ray fluorescence spectral element analysis with a spectrometer «M4 TORNADO» manufactured by Bruker (Germany) was applied. Results. Use of technical capabilities and software spectrometer «M4 TORNADO» provides new opportunities for laboratory diagnosis of various chemical elements in the tissues of biological and non-biological origin, including shot products through micro X-ray fluorescence spectral element analysis. Its advantages over similar methods are the possibility of mapping the topography as common maps of elements, maps for individual elements and their combinations. Analyzing the distribution pattern of elements on maps researcher has an opportunity to interpret the character of layers and background concentrations of the elements by their intensity. Conclusion. Tested equipment and program software opens new opportunities for laboratory diagnostics of shot products by their X-ray fluorescence spectral element analysis.http://morphology.dma.dp.ua/article/view/139600мікрорентгенівський флуоресцентний спектральний елементний аналізвогнепальні ушкодження
collection DOAJ
language Russian
format Article
sources DOAJ
author V. D. Mishalov
O. V. Michailenko
spellingShingle V. D. Mishalov
O. V. Michailenko
New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.
Морфологія
мікрорентгенівський флуоресцентний спектральний елементний аналіз
вогнепальні ушкодження
author_facet V. D. Mishalov
O. V. Michailenko
author_sort V. D. Mishalov
title New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.
title_short New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.
title_full New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.
title_fullStr New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.
title_full_unstemmed New opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.
title_sort new opportunities in laboratory diagnostics of shot products by their x-ray fluorescence spectral element analysis.
publisher Ministry of Health of Ukraine. Dnipropetrovsk Medical Academy
series Морфологія
issn 1997-9665
publishDate 2016-09-01
description Background. Optical Spectroscopic techniques widely used in practice despite the high sensitivity and wide range of studied chemical elements have the drawbacks, such as sample preparation, which is possible only in case of destruction of the investigated object. Non-destructive method to investigate the elemental composition of metal layers and other products of the shot is X-ray fluorescence spectral analysis, but the knowledge about the possibilities of modern equipment is incomplete. Objective. Identify chemical elements in damage simulator clothes at experimental shots from firearms through X-ray fluorescence spectral element analysis using a spectrometer «M4 TORNADO» manufactured by Bruker. Methods. The object of study was damaged clothe (patches of leather of jacket). Micro X-ray fluorescence spectral element analysis with a spectrometer «M4 TORNADO» manufactured by Bruker (Germany) was applied. Results. Use of technical capabilities and software spectrometer «M4 TORNADO» provides new opportunities for laboratory diagnosis of various chemical elements in the tissues of biological and non-biological origin, including shot products through micro X-ray fluorescence spectral element analysis. Its advantages over similar methods are the possibility of mapping the topography as common maps of elements, maps for individual elements and their combinations. Analyzing the distribution pattern of elements on maps researcher has an opportunity to interpret the character of layers and background concentrations of the elements by their intensity. Conclusion. Tested equipment and program software opens new opportunities for laboratory diagnostics of shot products by their X-ray fluorescence spectral element analysis.
topic мікрорентгенівський флуоресцентний спектральний елементний аналіз
вогнепальні ушкодження
url http://morphology.dma.dp.ua/article/view/139600
work_keys_str_mv AT vdmishalov newopportunitiesinlaboratorydiagnosticsofshotproductsbytheirxrayfluorescencespectralelementanalysis
AT ovmichailenko newopportunitiesinlaboratorydiagnosticsofshotproductsbytheirxrayfluorescencespectralelementanalysis
_version_ 1725645855728336896