Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophages

Insertion of metal implants is associated with a possible change in the delicate balance between pro- and anti-inflammatory proteins, probably leading to an unfavourable predominantly pro-inflammatory milieu. The most likely cause is an inappropriate activation of macrophages in close relation to th...

Full description

Bibliographic Details
Main Authors: S S Jakobsen, A Larsen, M Stoltenberg, J M Bruun, K Soballe
Format: Article
Language:English
Published: AO Research Institute Davos 2007-09-01
Series:European Cells & Materials
Subjects:
Online Access:http://www.ecmjournal.org/journal/papers/vol014/pdf/v014a05.pdf
id doaj-dd68b33ed4974d3e941af23c47eefbf5
record_format Article
spelling doaj-dd68b33ed4974d3e941af23c47eefbf52020-11-24T22:02:56Zeng AO Research Institute DavosEuropean Cells & Materials1473-22622007-09-01144555Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophagesS S JakobsenA LarsenM StoltenbergJ M BruunK SoballeInsertion of metal implants is associated with a possible change in the delicate balance between pro- and anti-inflammatory proteins, probably leading to an unfavourable predominantly pro-inflammatory milieu. The most likely cause is an inappropriate activation of macrophages in close relation to the metal implant and wear-products. The aim of the present study was to compare surfaces of as-cast and wrought Cobalt-Chrome-Molybdenum (CoCrMo) alloys and Titanium-Aluminium-Vanadium (TiAlV) alloy when incubated with mouse macrophage J774A.1 cell cultures. Changes in pro- and anti-inflammatory cytokines [TNF-alpha, IL-6, IL-alpha, IL-1beta, IL-10] and proteins known to induce proliferation [M-CSF], chemotaxis [MCP-1] and osteogenesis [TGF-beta, OPG] were determined by ELISA and Real Time reverse transcriptase - PCR (Real Time rt-PCR). Lactate dehydrogenase (LDH) was measured in the medium to asses the cell viability. Surface properties of the discs were characterised with a profilometer and with energy dispersive X-ray spectroscopy. We here report, for the first time, that the prosthetic material surface (non-phagocytable) of as-cast high carbon CoCrMo reduces the pro-inflammatory cytokine IL-6 transcription, the chemokine MCP-1 secretion, and M-CSF secretion by 77 %, 36 %, and 62 %, respectively. Furthermore, we found that reducing surface roughness did not affect this reduction. The results suggest that as-cast CoCrMo alloy is more inert than wrought CoCrMo and wrought TiAlV alloys and could prove to be a superior implant material generating less inflammation which might result in less osteolysis.http://www.ecmjournal.org/journal/papers/vol014/pdf/v014a05.pdfCoCrMotitaniuminflammationcytokinereal time RT-PCRsurfaceosteolysisJ774A.1 macrophagedissolucytosis
collection DOAJ
language English
format Article
sources DOAJ
author S S Jakobsen
A Larsen
M Stoltenberg
J M Bruun
K Soballe
spellingShingle S S Jakobsen
A Larsen
M Stoltenberg
J M Bruun
K Soballe
Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophages
European Cells & Materials
CoCrMo
titanium
inflammation
cytokine
real time RT-PCR
surface
osteolysis
J774A.1 macrophage
dissolucytosis
author_facet S S Jakobsen
A Larsen
M Stoltenberg
J M Bruun
K Soballe
author_sort S S Jakobsen
title Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophages
title_short Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophages
title_full Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophages
title_fullStr Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophages
title_full_unstemmed Effects of AS-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in J774A.1 macrophages
title_sort effects of as-cast and wrought cobalt-chrome-molybdenum and titanium-aluminium-vanadium alloys on cytokine gene expression and protein secretion in j774a.1 macrophages
publisher AO Research Institute Davos
series European Cells & Materials
issn 1473-2262
publishDate 2007-09-01
description Insertion of metal implants is associated with a possible change in the delicate balance between pro- and anti-inflammatory proteins, probably leading to an unfavourable predominantly pro-inflammatory milieu. The most likely cause is an inappropriate activation of macrophages in close relation to the metal implant and wear-products. The aim of the present study was to compare surfaces of as-cast and wrought Cobalt-Chrome-Molybdenum (CoCrMo) alloys and Titanium-Aluminium-Vanadium (TiAlV) alloy when incubated with mouse macrophage J774A.1 cell cultures. Changes in pro- and anti-inflammatory cytokines [TNF-alpha, IL-6, IL-alpha, IL-1beta, IL-10] and proteins known to induce proliferation [M-CSF], chemotaxis [MCP-1] and osteogenesis [TGF-beta, OPG] were determined by ELISA and Real Time reverse transcriptase - PCR (Real Time rt-PCR). Lactate dehydrogenase (LDH) was measured in the medium to asses the cell viability. Surface properties of the discs were characterised with a profilometer and with energy dispersive X-ray spectroscopy. We here report, for the first time, that the prosthetic material surface (non-phagocytable) of as-cast high carbon CoCrMo reduces the pro-inflammatory cytokine IL-6 transcription, the chemokine MCP-1 secretion, and M-CSF secretion by 77 %, 36 %, and 62 %, respectively. Furthermore, we found that reducing surface roughness did not affect this reduction. The results suggest that as-cast CoCrMo alloy is more inert than wrought CoCrMo and wrought TiAlV alloys and could prove to be a superior implant material generating less inflammation which might result in less osteolysis.
topic CoCrMo
titanium
inflammation
cytokine
real time RT-PCR
surface
osteolysis
J774A.1 macrophage
dissolucytosis
url http://www.ecmjournal.org/journal/papers/vol014/pdf/v014a05.pdf
work_keys_str_mv AT ssjakobsen effectsofascastandwroughtcobaltchromemolybdenumandtitaniumaluminiumvanadiumalloysoncytokinegeneexpressionandproteinsecretioninj774a1macrophages
AT alarsen effectsofascastandwroughtcobaltchromemolybdenumandtitaniumaluminiumvanadiumalloysoncytokinegeneexpressionandproteinsecretioninj774a1macrophages
AT mstoltenberg effectsofascastandwroughtcobaltchromemolybdenumandtitaniumaluminiumvanadiumalloysoncytokinegeneexpressionandproteinsecretioninj774a1macrophages
AT jmbruun effectsofascastandwroughtcobaltchromemolybdenumandtitaniumaluminiumvanadiumalloysoncytokinegeneexpressionandproteinsecretioninj774a1macrophages
AT ksoballe effectsofascastandwroughtcobaltchromemolybdenumandtitaniumaluminiumvanadiumalloysoncytokinegeneexpressionandproteinsecretioninj774a1macrophages
_version_ 1725833870528479232