Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor

We report our latest developments on a novel miniature particulate matter (PM) sensor for personal air quality monitoring. This optical sensor combines a visible fibered light source and a vertical air channel drilled out of a holed retina. The fabrication of such retina features an unconventional d...

Full description

Bibliographic Details
Main Authors: Gabriel Jobert, Pierre Barritault, Maryse Fournier, Salim Boutami, Daphnée Jobert, Adrien Marchant, Julien Michelot, Paul Monsinjon, Pierre Lienhard, Sergio Nicoletti
Format: Article
Language:English
Published: Elsevier 2020-11-01
Series:Sensors and Actuators Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666053920300072
id doaj-dcf18fdfd4994f7b879255d8307865d9
record_format Article
spelling doaj-dcf18fdfd4994f7b879255d8307865d92021-05-01T04:36:11ZengElsevierSensors and Actuators Reports2666-05392020-11-0121100010Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensorGabriel Jobert0Pierre Barritault1Maryse Fournier2Salim Boutami3Daphnée Jobert4Adrien Marchant5Julien Michelot6Paul Monsinjon7Pierre Lienhard8Sergio Nicoletti9CEA-LETI Minatec, Université Grenoble-Alpes, F38000 Grenoble, France; Corresponding author.CEA-LETI Minatec, Université Grenoble-Alpes, F38000 Grenoble, FranceCEA-LETI Minatec, Université Grenoble-Alpes, F38000 Grenoble, FranceCEA-LETI Minatec, Université Grenoble-Alpes, F38000 Grenoble, FranceCEA-LETI Minatec, Université Grenoble-Alpes, F38000 Grenoble, FranceCEA-LETI Minatec, Université Grenoble-Alpes, F38000 Grenoble, FrancePyxalis, Moirans, FrancePyxalis, Moirans, FrancePyxalis, Moirans, FranceCEA-LETI Minatec, Université Grenoble-Alpes, F38000 Grenoble, FranceWe report our latest developments on a novel miniature particulate matter (PM) sensor for personal air quality monitoring. This optical sensor combines a visible fibered light source and a vertical air channel drilled out of a holed retina. The fabrication of such retina features an unconventional design of a CMOS image sensor and a specific drilling post process at wafer level. The scattering of light by a single particle generates a distinctive pattern. By using a compact optical set-up, we measure a lens-free projection of the scattering signature on the image sensor. We present the design and fabrication of such sensor as well as experimental signatures that are consistent with our in-house analytical model. We demonstrate counting and differentiation between calibrated particles of different sizes. Our current setup allows for the detection of single 320 nm polystyrene particles. Finally, we describe our image analysis procedure that fits a measured signature with a modelled one in order to retrieve particle's size and refractive index.http://www.sciencedirect.com/science/article/pii/S2666053920300072Air qualityParticulate matter sensorLight-scatteringCMOS image sensorLens-free imagingImage processing
collection DOAJ
language English
format Article
sources DOAJ
author Gabriel Jobert
Pierre Barritault
Maryse Fournier
Salim Boutami
Daphnée Jobert
Adrien Marchant
Julien Michelot
Paul Monsinjon
Pierre Lienhard
Sergio Nicoletti
spellingShingle Gabriel Jobert
Pierre Barritault
Maryse Fournier
Salim Boutami
Daphnée Jobert
Adrien Marchant
Julien Michelot
Paul Monsinjon
Pierre Lienhard
Sergio Nicoletti
Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor
Sensors and Actuators Reports
Air quality
Particulate matter sensor
Light-scattering
CMOS image sensor
Lens-free imaging
Image processing
author_facet Gabriel Jobert
Pierre Barritault
Maryse Fournier
Salim Boutami
Daphnée Jobert
Adrien Marchant
Julien Michelot
Paul Monsinjon
Pierre Lienhard
Sergio Nicoletti
author_sort Gabriel Jobert
title Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor
title_short Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor
title_full Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor
title_fullStr Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor
title_full_unstemmed Miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor
title_sort miniature particulate matter counter and analyzer based on lens-free imaging of light scattering signatures with a holed image sensor
publisher Elsevier
series Sensors and Actuators Reports
issn 2666-0539
publishDate 2020-11-01
description We report our latest developments on a novel miniature particulate matter (PM) sensor for personal air quality monitoring. This optical sensor combines a visible fibered light source and a vertical air channel drilled out of a holed retina. The fabrication of such retina features an unconventional design of a CMOS image sensor and a specific drilling post process at wafer level. The scattering of light by a single particle generates a distinctive pattern. By using a compact optical set-up, we measure a lens-free projection of the scattering signature on the image sensor. We present the design and fabrication of such sensor as well as experimental signatures that are consistent with our in-house analytical model. We demonstrate counting and differentiation between calibrated particles of different sizes. Our current setup allows for the detection of single 320 nm polystyrene particles. Finally, we describe our image analysis procedure that fits a measured signature with a modelled one in order to retrieve particle's size and refractive index.
topic Air quality
Particulate matter sensor
Light-scattering
CMOS image sensor
Lens-free imaging
Image processing
url http://www.sciencedirect.com/science/article/pii/S2666053920300072
work_keys_str_mv AT gabrieljobert miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT pierrebarritault miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT marysefournier miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT salimboutami miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT daphneejobert miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT adrienmarchant miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT julienmichelot miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT paulmonsinjon miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT pierrelienhard miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
AT sergionicoletti miniatureparticulatemattercounterandanalyzerbasedonlensfreeimagingoflightscatteringsignatureswithaholedimagesensor
_version_ 1721496980167852032