The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study
Objective The goal of this study was to establish a numeric threshold to separate functional from substantially obstructed noses using comparisons of thermal imaging and subjective scores. Study Design An inexpensive smartphone application and hardware attachment that uses infrared thermal imaging w...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2021-09-01
|
Series: | OTO Open |
Online Access: | https://doi.org/10.1177/2473974X211045958 |
id |
doaj-dccdc78d1a964f3a95b3f83a61b391c0 |
---|---|
record_format |
Article |
spelling |
doaj-dccdc78d1a964f3a95b3f83a61b391c02021-10-01T21:33:59ZengSAGE PublishingOTO Open2473-974X2021-09-01510.1177/2473974X211045958The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot StudySydney Jiang MD0Jason Chan MD1Howard D. Stupak MD2Department of Otorhinolaryngology–Head and Neck Surgery, Montefiore Medical Center/Children’s Hospital of Montefiore, Bronx, New York, USAAlbert Einstein College of Medicine, Bronx, New York, USADivision of Otorhinolaryngology–Head and Neck Surgery, Department of Surgery, Jacobi Medical Center, Albert Einstein College of Medicine, Bronx, New York, USAObjective The goal of this study was to establish a numeric threshold to separate functional from substantially obstructed noses using comparisons of thermal imaging and subjective scores. Study Design An inexpensive smartphone application and hardware attachment that uses infrared thermal imaging was tested to differentiate between substantial nasal blockage from an adequately functioning nose. Setting Sequential adult participants who presented to a public hospital otolaryngology clinic between June and August 2018 were asked to complete the Nasal Obstruction Symptom Evaluation (NOSE) tool. Methods A thermal video imaging device was used to record the difference in temperature (ΔT) between inspired (I) and expired (E) air at each nostril. The nostril ΔT between I and E air of patients with severe obstruction by the subjective measure (NOSE score) was compared with that of patients with minimal symptoms. Results A total of 26 participants were enrolled in the study. During normal respiration, Total ΔT for the nonobstructed group had a mean of 9.0, whereas the Total ΔT for the obstructed group had a mean of 7.69, a 17% difference that was statistically significant at P = .045. For the worst-performing nostril tested, ΔT for the nonobstructed group had a mean/median of 4°C, while the obstructed group had a mean of 3.23°C (median 3; 23.8% difference, P = .023). Conclusion Measures of thermal imaging, particularly at the threshold between the median scores of the worst-performing nostril, may be a useful clinical test to differentiate between a substantially obstructed nose from an adequately functioning nose, although more data are required.https://doi.org/10.1177/2473974X211045958 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sydney Jiang MD Jason Chan MD Howard D. Stupak MD |
spellingShingle |
Sydney Jiang MD Jason Chan MD Howard D. Stupak MD The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study OTO Open |
author_facet |
Sydney Jiang MD Jason Chan MD Howard D. Stupak MD |
author_sort |
Sydney Jiang MD |
title |
The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study |
title_short |
The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study |
title_full |
The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study |
title_fullStr |
The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study |
title_full_unstemmed |
The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study |
title_sort |
use of infrared thermal imaging to determine functional nasal adequacy: a pilot study |
publisher |
SAGE Publishing |
series |
OTO Open |
issn |
2473-974X |
publishDate |
2021-09-01 |
description |
Objective The goal of this study was to establish a numeric threshold to separate functional from substantially obstructed noses using comparisons of thermal imaging and subjective scores. Study Design An inexpensive smartphone application and hardware attachment that uses infrared thermal imaging was tested to differentiate between substantial nasal blockage from an adequately functioning nose. Setting Sequential adult participants who presented to a public hospital otolaryngology clinic between June and August 2018 were asked to complete the Nasal Obstruction Symptom Evaluation (NOSE) tool. Methods A thermal video imaging device was used to record the difference in temperature (ΔT) between inspired (I) and expired (E) air at each nostril. The nostril ΔT between I and E air of patients with severe obstruction by the subjective measure (NOSE score) was compared with that of patients with minimal symptoms. Results A total of 26 participants were enrolled in the study. During normal respiration, Total ΔT for the nonobstructed group had a mean of 9.0, whereas the Total ΔT for the obstructed group had a mean of 7.69, a 17% difference that was statistically significant at P = .045. For the worst-performing nostril tested, ΔT for the nonobstructed group had a mean/median of 4°C, while the obstructed group had a mean of 3.23°C (median 3; 23.8% difference, P = .023). Conclusion Measures of thermal imaging, particularly at the threshold between the median scores of the worst-performing nostril, may be a useful clinical test to differentiate between a substantially obstructed nose from an adequately functioning nose, although more data are required. |
url |
https://doi.org/10.1177/2473974X211045958 |
work_keys_str_mv |
AT sydneyjiangmd theuseofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy AT jasonchanmd theuseofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy AT howarddstupakmd theuseofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy AT sydneyjiangmd useofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy AT jasonchanmd useofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy AT howarddstupakmd useofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy |
_version_ |
1716860740696014848 |