The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study

Objective The goal of this study was to establish a numeric threshold to separate functional from substantially obstructed noses using comparisons of thermal imaging and subjective scores. Study Design An inexpensive smartphone application and hardware attachment that uses infrared thermal imaging w...

Full description

Bibliographic Details
Main Authors: Sydney Jiang MD, Jason Chan MD, Howard D. Stupak MD
Format: Article
Language:English
Published: SAGE Publishing 2021-09-01
Series:OTO Open
Online Access:https://doi.org/10.1177/2473974X211045958
id doaj-dccdc78d1a964f3a95b3f83a61b391c0
record_format Article
spelling doaj-dccdc78d1a964f3a95b3f83a61b391c02021-10-01T21:33:59ZengSAGE PublishingOTO Open2473-974X2021-09-01510.1177/2473974X211045958The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot StudySydney Jiang MD0Jason Chan MD1Howard D. Stupak MD2Department of Otorhinolaryngology–Head and Neck Surgery, Montefiore Medical Center/Children’s Hospital of Montefiore, Bronx, New York, USAAlbert Einstein College of Medicine, Bronx, New York, USADivision of Otorhinolaryngology–Head and Neck Surgery, Department of Surgery, Jacobi Medical Center, Albert Einstein College of Medicine, Bronx, New York, USAObjective The goal of this study was to establish a numeric threshold to separate functional from substantially obstructed noses using comparisons of thermal imaging and subjective scores. Study Design An inexpensive smartphone application and hardware attachment that uses infrared thermal imaging was tested to differentiate between substantial nasal blockage from an adequately functioning nose. Setting Sequential adult participants who presented to a public hospital otolaryngology clinic between June and August 2018 were asked to complete the Nasal Obstruction Symptom Evaluation (NOSE) tool. Methods A thermal video imaging device was used to record the difference in temperature (ΔT) between inspired (I) and expired (E) air at each nostril. The nostril ΔT between I and E air of patients with severe obstruction by the subjective measure (NOSE score) was compared with that of patients with minimal symptoms. Results A total of 26 participants were enrolled in the study. During normal respiration, Total ΔT for the nonobstructed group had a mean of 9.0, whereas the Total ΔT for the obstructed group had a mean of 7.69, a 17% difference that was statistically significant at P = .045. For the worst-performing nostril tested, ΔT for the nonobstructed group had a mean/median of 4°C, while the obstructed group had a mean of 3.23°C (median 3; 23.8% difference, P = .023). Conclusion Measures of thermal imaging, particularly at the threshold between the median scores of the worst-performing nostril, may be a useful clinical test to differentiate between a substantially obstructed nose from an adequately functioning nose, although more data are required.https://doi.org/10.1177/2473974X211045958
collection DOAJ
language English
format Article
sources DOAJ
author Sydney Jiang MD
Jason Chan MD
Howard D. Stupak MD
spellingShingle Sydney Jiang MD
Jason Chan MD
Howard D. Stupak MD
The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study
OTO Open
author_facet Sydney Jiang MD
Jason Chan MD
Howard D. Stupak MD
author_sort Sydney Jiang MD
title The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study
title_short The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study
title_full The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study
title_fullStr The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study
title_full_unstemmed The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study
title_sort use of infrared thermal imaging to determine functional nasal adequacy: a pilot study
publisher SAGE Publishing
series OTO Open
issn 2473-974X
publishDate 2021-09-01
description Objective The goal of this study was to establish a numeric threshold to separate functional from substantially obstructed noses using comparisons of thermal imaging and subjective scores. Study Design An inexpensive smartphone application and hardware attachment that uses infrared thermal imaging was tested to differentiate between substantial nasal blockage from an adequately functioning nose. Setting Sequential adult participants who presented to a public hospital otolaryngology clinic between June and August 2018 were asked to complete the Nasal Obstruction Symptom Evaluation (NOSE) tool. Methods A thermal video imaging device was used to record the difference in temperature (ΔT) between inspired (I) and expired (E) air at each nostril. The nostril ΔT between I and E air of patients with severe obstruction by the subjective measure (NOSE score) was compared with that of patients with minimal symptoms. Results A total of 26 participants were enrolled in the study. During normal respiration, Total ΔT for the nonobstructed group had a mean of 9.0, whereas the Total ΔT for the obstructed group had a mean of 7.69, a 17% difference that was statistically significant at P = .045. For the worst-performing nostril tested, ΔT for the nonobstructed group had a mean/median of 4°C, while the obstructed group had a mean of 3.23°C (median 3; 23.8% difference, P = .023). Conclusion Measures of thermal imaging, particularly at the threshold between the median scores of the worst-performing nostril, may be a useful clinical test to differentiate between a substantially obstructed nose from an adequately functioning nose, although more data are required.
url https://doi.org/10.1177/2473974X211045958
work_keys_str_mv AT sydneyjiangmd theuseofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy
AT jasonchanmd theuseofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy
AT howarddstupakmd theuseofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy
AT sydneyjiangmd useofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy
AT jasonchanmd useofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy
AT howarddstupakmd useofinfraredthermalimagingtodeterminefunctionalnasaladequacyapilotstudy
_version_ 1716860740696014848