Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique
Medial meniscus posterior root tear is a disruptive injury causing significant sequelae. Several techniques to repair and maintain the native function of the medial meniscus have been introduced, but limitations have been reported in terms of their results. In this current note, the authors introduc...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2021-04-01
|
Series: | Arthroscopy Techniques |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2212628720303832 |
id |
doaj-dcafd3595067482c878731f27c33e763 |
---|---|
record_format |
Article |
spelling |
doaj-dcafd3595067482c878731f27c33e7632021-06-11T05:14:15ZengElsevierArthroscopy Techniques2212-62872021-04-01104e1017e1024Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture TechniqueJoo-Hwan Kim, M.D.0Dong-Jin Ryu, M.D.1Jae Sung Park, M.D.2Tae Soo Shin, M.D.3Joon Ho Wang, M.D., Ph.D.4Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South KoreaDepartment of Orthopedic Surgery, Inha University Hospital, Inha University School of Medicine, Incheon, South KoreaDepartment of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South KoreaDepartment of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South KoreaDepartment of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea; Department of Health Sciences and Technology and Department of Medical Device Management and Research, SAIHST, Sungkyunkwan University, Seoul, South Korea; Address correspondence to Joon Ho Wang, M.D., Ph.D., Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea; and Department of Health Sciences and Technology and Department of Medical Device Management and Research, SAIHST, Sungkyunkwan University, Seoul 06351, Korea.Medial meniscus posterior root tear is a disruptive injury causing significant sequelae. Several techniques to repair and maintain the native function of the medial meniscus have been introduced, but limitations have been reported in terms of their results. In this current note, the authors introduce the arthroscopic transtibial pull-out repair with whip running suture technique, which may not only avoid the potential risk of meniscus cut-through by the suture material but also optimize the reduction of the extruded meniscus. By suturing the posteromedial capsule and peripheral meniscus, more medialization force can be directly applied to the extruded part of the meniscus, and normal hoop tension can be restored.http://www.sciencedirect.com/science/article/pii/S2212628720303832 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Joo-Hwan Kim, M.D. Dong-Jin Ryu, M.D. Jae Sung Park, M.D. Tae Soo Shin, M.D. Joon Ho Wang, M.D., Ph.D. |
spellingShingle |
Joo-Hwan Kim, M.D. Dong-Jin Ryu, M.D. Jae Sung Park, M.D. Tae Soo Shin, M.D. Joon Ho Wang, M.D., Ph.D. Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique Arthroscopy Techniques |
author_facet |
Joo-Hwan Kim, M.D. Dong-Jin Ryu, M.D. Jae Sung Park, M.D. Tae Soo Shin, M.D. Joon Ho Wang, M.D., Ph.D. |
author_sort |
Joo-Hwan Kim, M.D. |
title |
Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique |
title_short |
Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique |
title_full |
Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique |
title_fullStr |
Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique |
title_full_unstemmed |
Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique |
title_sort |
arthroscopic transtibial pull-out repair of medial meniscus posterior root tear with a whip running suture technique |
publisher |
Elsevier |
series |
Arthroscopy Techniques |
issn |
2212-6287 |
publishDate |
2021-04-01 |
description |
Medial meniscus posterior root tear is a disruptive injury causing significant sequelae. Several techniques to repair and maintain the native function of the medial meniscus have been introduced, but limitations have been reported in terms of their results. In this current note, the authors introduce the arthroscopic transtibial pull-out repair with whip running suture technique, which may not only avoid the potential risk of meniscus cut-through by the suture material but also optimize the reduction of the extruded meniscus. By suturing the posteromedial capsule and peripheral meniscus, more medialization force can be directly applied to the extruded part of the meniscus, and normal hoop tension can be restored. |
url |
http://www.sciencedirect.com/science/article/pii/S2212628720303832 |
work_keys_str_mv |
AT joohwankimmd arthroscopictranstibialpulloutrepairofmedialmeniscusposteriorroottearwithawhiprunningsuturetechnique AT dongjinryumd arthroscopictranstibialpulloutrepairofmedialmeniscusposteriorroottearwithawhiprunningsuturetechnique AT jaesungparkmd arthroscopictranstibialpulloutrepairofmedialmeniscusposteriorroottearwithawhiprunningsuturetechnique AT taesooshinmd arthroscopictranstibialpulloutrepairofmedialmeniscusposteriorroottearwithawhiprunningsuturetechnique AT joonhowangmdphd arthroscopictranstibialpulloutrepairofmedialmeniscusposteriorroottearwithawhiprunningsuturetechnique |
_version_ |
1721383528284815360 |