Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat Exchangers
Ground-source heat pump systems are renewable and highly efficient HVAC systems that utilise the ground to exchange heat via ground heat exchangers (GHEs). This study developed a detailed 3D finite element model for horizontal GHEs by using COMSOL Multiphysics and validated it against a fully instru...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-06-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/13/3919 |
id |
doaj-dc918f6cea944af29e692b30ce8f0e72 |
---|---|
record_format |
Article |
spelling |
doaj-dc918f6cea944af29e692b30ce8f0e722021-07-15T15:33:25ZengMDPI AGEnergies1996-10732021-06-01143919391910.3390/en14133919Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat ExchangersYu Zhou0Asal Bidarmaghz1Nikolas Makasis2Guillermo Narsilio3China Construction Science and Technology Group Co. Ltd., Shenzhen 518000, ChinaSchool of Civil and Environmental Engineering, University of New South Wales, Sydney, NSW 2052, AustraliaDepartment of Infrastructure Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC 3010, AustraliaDepartment of Infrastructure Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC 3010, AustraliaGround-source heat pump systems are renewable and highly efficient HVAC systems that utilise the ground to exchange heat via ground heat exchangers (GHEs). This study developed a detailed 3D finite element model for horizontal GHEs by using COMSOL Multiphysics and validated it against a fully instrumented system under the loading conditions of rural industries in NSW, Australia. First, the yearly performance evaluation of the horizontal straight GHEs showed an adequate initial design under the unique loads. This study then evaluated the effects of variable trench separations, GHE configurations, and effective thermal conductivity. Different trench separations that varied between 1.2 and 3.5 m were selected and analysed while considering three different horizontal loop configurations, i.e., the horizontal straight, slinky, and dense slinky loop configurations. These configurations had the same length of pipe in one trench, and the first two had the same trench length as well. The results revealed that when the trench separation became smaller, there was a minor increasing trend (0.5 °C) in the carrier fluid temperature. As for the configuration, the dense slinky loop showed an average that was 1.5 °C lower than those of the horizontal straight and slinky loop (which were about the same). This indicates that, when land is limited, compromises on the trench separation should be made first in lieu of changes in the loop configuration. Lastly, the results showed that although the effective thermal conductivity had an impact on the carrier fluid temperature, this impact was much lower compared to that for the GHE configurations and trench separations.https://www.mdpi.com/1996-1073/14/13/3919ground-source heat pumpshorizontal ground heat exchangersfinite element modelling |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Yu Zhou Asal Bidarmaghz Nikolas Makasis Guillermo Narsilio |
spellingShingle |
Yu Zhou Asal Bidarmaghz Nikolas Makasis Guillermo Narsilio Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat Exchangers Energies ground-source heat pumps horizontal ground heat exchangers finite element modelling |
author_facet |
Yu Zhou Asal Bidarmaghz Nikolas Makasis Guillermo Narsilio |
author_sort |
Yu Zhou |
title |
Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat Exchangers |
title_short |
Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat Exchangers |
title_full |
Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat Exchangers |
title_fullStr |
Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat Exchangers |
title_full_unstemmed |
Ground-Source Heat Pump Systems: The Effects of Variable Trench Separations and Pipe Configurations in Horizontal Ground Heat Exchangers |
title_sort |
ground-source heat pump systems: the effects of variable trench separations and pipe configurations in horizontal ground heat exchangers |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2021-06-01 |
description |
Ground-source heat pump systems are renewable and highly efficient HVAC systems that utilise the ground to exchange heat via ground heat exchangers (GHEs). This study developed a detailed 3D finite element model for horizontal GHEs by using COMSOL Multiphysics and validated it against a fully instrumented system under the loading conditions of rural industries in NSW, Australia. First, the yearly performance evaluation of the horizontal straight GHEs showed an adequate initial design under the unique loads. This study then evaluated the effects of variable trench separations, GHE configurations, and effective thermal conductivity. Different trench separations that varied between 1.2 and 3.5 m were selected and analysed while considering three different horizontal loop configurations, i.e., the horizontal straight, slinky, and dense slinky loop configurations. These configurations had the same length of pipe in one trench, and the first two had the same trench length as well. The results revealed that when the trench separation became smaller, there was a minor increasing trend (0.5 °C) in the carrier fluid temperature. As for the configuration, the dense slinky loop showed an average that was 1.5 °C lower than those of the horizontal straight and slinky loop (which were about the same). This indicates that, when land is limited, compromises on the trench separation should be made first in lieu of changes in the loop configuration. Lastly, the results showed that although the effective thermal conductivity had an impact on the carrier fluid temperature, this impact was much lower compared to that for the GHE configurations and trench separations. |
topic |
ground-source heat pumps horizontal ground heat exchangers finite element modelling |
url |
https://www.mdpi.com/1996-1073/14/13/3919 |
work_keys_str_mv |
AT yuzhou groundsourceheatpumpsystemstheeffectsofvariabletrenchseparationsandpipeconfigurationsinhorizontalgroundheatexchangers AT asalbidarmaghz groundsourceheatpumpsystemstheeffectsofvariabletrenchseparationsandpipeconfigurationsinhorizontalgroundheatexchangers AT nikolasmakasis groundsourceheatpumpsystemstheeffectsofvariabletrenchseparationsandpipeconfigurationsinhorizontalgroundheatexchangers AT guillermonarsilio groundsourceheatpumpsystemstheeffectsofvariabletrenchseparationsandpipeconfigurationsinhorizontalgroundheatexchangers |
_version_ |
1721299723156979712 |