Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucoma

Abstract Previous epidemiological studies have demonstrated that the lower serum concentration of vitamin D was associated with elevated risk of open-angle glaucoma (OAG). However, few studies have examined the association between aqueous humor vitamin D concentrations and OAG. Hence, we investigate...

Full description

Bibliographic Details
Main Authors: Yongwun Cho, Seung Pil Yun, Woong-Sun Yoo, Rock-Bum Kim, Min-Chul Cho, Seong-Jae Kim
Format: Article
Language:English
Published: Nature Publishing Group 2021-09-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-021-98342-9
id doaj-dc551e143dd044078d6575f0949e407b
record_format Article
spelling doaj-dc551e143dd044078d6575f0949e407b2021-09-26T11:30:38ZengNature Publishing GroupScientific Reports2045-23222021-09-011111810.1038/s41598-021-98342-9Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucomaYongwun Cho0Seung Pil Yun1Woong-Sun Yoo2Rock-Bum Kim3Min-Chul Cho4Seong-Jae Kim5Department of Ophthalmology, Gyeongsang National University Hospital and Gyeongsang National University College of MedicineDepartment of Pharmacology and Convergence Medical Science, Institute of Health Sciences, College of Medicine, Gyeongsang National UniversityDepartment of Ophthalmology, Gyeongsang National University Hospital and Gyeongsang National University College of MedicineDepartment of Preventive Medicine, Gyeongsang National University Hospital and Gyeongsang National University College of MedicineInstitute of Health Science, Gyeongsang National UniversityDepartment of Ophthalmology, Gyeongsang National University Hospital and Gyeongsang National University College of MedicineAbstract Previous epidemiological studies have demonstrated that the lower serum concentration of vitamin D was associated with elevated risk of open-angle glaucoma (OAG). However, few studies have examined the association between aqueous humor vitamin D concentrations and OAG. Hence, we investigated the relationship between 25-hydroxyvitamin D (25(OH)D) concentrations in aqueous humor and OAG. We measured 25(OH)D concentrations in aqueous humor and serum of 126 patients who underwent cataract surgery. 36 were patients with OAG and 90 were control patients. The 25(OH)D concentrations were measured using Elecsys Vitamin D Total Kits with the Cobas e602 module (Roche Diagnostics, Mannheim, Germany), an electrochemiluminescence assay. Multiple linear regression analysis was performed to investigate factors associated with serum and aqueous humor 25(OH)D concentrations. Patients with OAG had significantly lower 25(OH)D concentrations in aqueous humor than control patients. Serum 25(OH)D concentrations were higher in patients with OAG than in the control, but this was not statistically significant. 25(OH)D concentrations in aqueous humor of patients with OAG were significantly associated with axial length but not with glaucoma severity, which was determined by the retinal nerve fiber layer thickness or mean deviation. Vitamin D concentrations in aqueous humor of patients with OAG were significantly lower than those in patients without OAG.https://doi.org/10.1038/s41598-021-98342-9
collection DOAJ
language English
format Article
sources DOAJ
author Yongwun Cho
Seung Pil Yun
Woong-Sun Yoo
Rock-Bum Kim
Min-Chul Cho
Seong-Jae Kim
spellingShingle Yongwun Cho
Seung Pil Yun
Woong-Sun Yoo
Rock-Bum Kim
Min-Chul Cho
Seong-Jae Kim
Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucoma
Scientific Reports
author_facet Yongwun Cho
Seung Pil Yun
Woong-Sun Yoo
Rock-Bum Kim
Min-Chul Cho
Seong-Jae Kim
author_sort Yongwun Cho
title Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucoma
title_short Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucoma
title_full Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucoma
title_fullStr Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucoma
title_full_unstemmed Reduced 25-hydroxyvitamin D concentration in the aqueous humor of cataract patients with open-angle glaucoma
title_sort reduced 25-hydroxyvitamin d concentration in the aqueous humor of cataract patients with open-angle glaucoma
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2021-09-01
description Abstract Previous epidemiological studies have demonstrated that the lower serum concentration of vitamin D was associated with elevated risk of open-angle glaucoma (OAG). However, few studies have examined the association between aqueous humor vitamin D concentrations and OAG. Hence, we investigated the relationship between 25-hydroxyvitamin D (25(OH)D) concentrations in aqueous humor and OAG. We measured 25(OH)D concentrations in aqueous humor and serum of 126 patients who underwent cataract surgery. 36 were patients with OAG and 90 were control patients. The 25(OH)D concentrations were measured using Elecsys Vitamin D Total Kits with the Cobas e602 module (Roche Diagnostics, Mannheim, Germany), an electrochemiluminescence assay. Multiple linear regression analysis was performed to investigate factors associated with serum and aqueous humor 25(OH)D concentrations. Patients with OAG had significantly lower 25(OH)D concentrations in aqueous humor than control patients. Serum 25(OH)D concentrations were higher in patients with OAG than in the control, but this was not statistically significant. 25(OH)D concentrations in aqueous humor of patients with OAG were significantly associated with axial length but not with glaucoma severity, which was determined by the retinal nerve fiber layer thickness or mean deviation. Vitamin D concentrations in aqueous humor of patients with OAG were significantly lower than those in patients without OAG.
url https://doi.org/10.1038/s41598-021-98342-9
work_keys_str_mv AT yongwuncho reduced25hydroxyvitamindconcentrationintheaqueoushumorofcataractpatientswithopenangleglaucoma
AT seungpilyun reduced25hydroxyvitamindconcentrationintheaqueoushumorofcataractpatientswithopenangleglaucoma
AT woongsunyoo reduced25hydroxyvitamindconcentrationintheaqueoushumorofcataractpatientswithopenangleglaucoma
AT rockbumkim reduced25hydroxyvitamindconcentrationintheaqueoushumorofcataractpatientswithopenangleglaucoma
AT minchulcho reduced25hydroxyvitamindconcentrationintheaqueoushumorofcataractpatientswithopenangleglaucoma
AT seongjaekim reduced25hydroxyvitamindconcentrationintheaqueoushumorofcataractpatientswithopenangleglaucoma
_version_ 1716867970959933440