Applying Differential Wave-Front Sensing and Differential Power Sensing for Simultaneous Precise and Wide-Range Test-Mass Rotation Measurements

We propose to combine differential wave-front sensing (DWS) and differential power sensing (DPS) in a Mach-Zehnder type interferometer for measuring the rotational dynamics of a test-mass. Using the DWS method, a high sensitive measurement of 6 nrad Hz<sup>−1/2</sup> in sub-Hz frequencie...

Full description

Bibliographic Details
Main Authors: Neda Meshksar, Moritz Mehmet, Katharina-Sophie Isleif, Gerhard Heinzel
Format: Article
Language:English
Published: MDPI AG 2021-12-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/21/1/164
Description
Summary:We propose to combine differential wave-front sensing (DWS) and differential power sensing (DPS) in a Mach-Zehnder type interferometer for measuring the rotational dynamics of a test-mass. Using the DWS method, a high sensitive measurement of 6 nrad Hz<sup>−1/2</sup> in sub-Hz frequencies can be provided around the test-mass nominal position (<inline-formula><math display="inline"><semantics><mrow><mo>±</mo><mn>0.11</mn></mrow></semantics></math></inline-formula> mrad), whereas the measurement of a wide rotation range (<inline-formula><math display="inline"><semantics><mrow><mo>±</mo><mn>5</mn></mrow></semantics></math></inline-formula> mrad) is realized by the DPS method. The interferometer can be combined with deep frequency modulation (DFM) interferometry for measurement of the test-mass translational dynamics. The setup and the resulting interferometric signals are verified by simulations. An optimization algorithm is applied to find suitable positions of the lenses and the waist size of the input laser in order to determine the best trade of between the slope of DWS, dynamic range of DPS, and the interferometric contrast. Our simulation further allows to investigate the layout for robustness and design tolerances. We compare our device with a recent experimental realization of a DFM interferometer and find that a practical implementation of the interferometer proposed here has the potential to provide translational and rotational test-mass tracking with state-of-the-art sensitivity. The simple and compact design, and especially the capability of sensing the test-mass rotation in a wide range and simultaneously providing a high-precision measurement close to the test-mass nominal position makes the design especially suitable for example for employment in torsion pendulum setups.
ISSN:1424-8220