Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado

<p>We assessed the performance of ambient ozone (O<sub>3</sub>) and carbon dioxide (CO<sub>2</sub>) sensor field calibration techniques when they were generated using data from one location and then applied to data collected at a new location. This was motivated by a...

Full description

Bibliographic Details
Main Authors: J. G. Casey, M. P. Hannigan
Format: Article
Language:English
Published: Copernicus Publications 2018-11-01
Series:Atmospheric Measurement Techniques
Online Access:https://www.atmos-meas-tech.net/11/6351/2018/amt-11-6351-2018.pdf
id doaj-da7f9f98158545e09b9bcb439487827d
record_format Article
spelling doaj-da7f9f98158545e09b9bcb439487827d2020-11-24T20:43:31ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482018-11-01116351637810.5194/amt-11-6351-2018Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across ColoradoJ. G. Casey0M. P. Hannigan1Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, 80309, USADepartment of Mechanical Engineering, University of Colorado at Boulder, Boulder, 80309, USA<p>We assessed the performance of ambient ozone (O<sub>3</sub>) and carbon dioxide (CO<sub>2</sub>) sensor field calibration techniques when they were generated using data from one location and then applied to data collected at a new location. This was motivated by a previous study (Casey et al., 2018), which highlighted the importance of determining the extent to which field calibration regression models could be aided by relationships among atmospheric trace gases at a given training location, which may not hold if a model is applied to data collected in a new location. We also explored the sensitivity of these methods in response to the timing of field calibrations relative to deployment periods. Employing data from a number of field deployments in Colorado and New Mexico that spanned several years, we tested and compared the performance of field-calibrated sensors using both linear models (LMs) and artificial neural networks (ANNs) for regression. Sampling sites covered urban and rural–peri-urban areas and environments influenced by oil and gas production. We found that the best-performing model inputs and model type depended on circumstances associated with individual case studies, such as differing characteristics of local dominant emissions sources, relative timing of model training and application, and the extent of extrapolation outside of parameter space encompassed by model training. In agreement with findings from our previous study that was focused on data from a single location (Casey et al., 2018), ANNs remained more effective than LMs for a number of these case studies but there were some exceptions. For CO<sub>2</sub> models, exceptions included case studies in which training data collection took place more than several months subsequent to the test data period. For O<sub>3</sub> models, exceptions included case studies in which the characteristics of dominant local emissions sources (oil and gas vs. urban) were significantly different at model training and testing locations. Among models that were tailored to case studies on an individual basis, O<sub>3</sub> ANNs performed better than O<sub>3</sub> LMs in six out of seven case studies, while CO<sub>2</sub> ANNs performed better than CO<sub>2</sub> LMs in three out of five case studies. The performance of O<sub>3</sub> models tended to be more sensitive to deployment location than to extrapolation in time, while the performance of CO<sub>2</sub> models tended to be more sensitive to extrapolation in time than to deployment location. The performance of O<sub>3</sub> ANN models benefited from the inclusion of several secondary metal-oxide-type sensors as inputs in five of seven case studies.</p>https://www.atmos-meas-tech.net/11/6351/2018/amt-11-6351-2018.pdf
collection DOAJ
language English
format Article
sources DOAJ
author J. G. Casey
M. P. Hannigan
spellingShingle J. G. Casey
M. P. Hannigan
Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado
Atmospheric Measurement Techniques
author_facet J. G. Casey
M. P. Hannigan
author_sort J. G. Casey
title Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado
title_short Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado
title_full Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado
title_fullStr Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado
title_full_unstemmed Testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across Colorado
title_sort testing the performance of field calibration techniques for low-cost gas sensors in new deployment locations: across a county line and across colorado
publisher Copernicus Publications
series Atmospheric Measurement Techniques
issn 1867-1381
1867-8548
publishDate 2018-11-01
description <p>We assessed the performance of ambient ozone (O<sub>3</sub>) and carbon dioxide (CO<sub>2</sub>) sensor field calibration techniques when they were generated using data from one location and then applied to data collected at a new location. This was motivated by a previous study (Casey et al., 2018), which highlighted the importance of determining the extent to which field calibration regression models could be aided by relationships among atmospheric trace gases at a given training location, which may not hold if a model is applied to data collected in a new location. We also explored the sensitivity of these methods in response to the timing of field calibrations relative to deployment periods. Employing data from a number of field deployments in Colorado and New Mexico that spanned several years, we tested and compared the performance of field-calibrated sensors using both linear models (LMs) and artificial neural networks (ANNs) for regression. Sampling sites covered urban and rural–peri-urban areas and environments influenced by oil and gas production. We found that the best-performing model inputs and model type depended on circumstances associated with individual case studies, such as differing characteristics of local dominant emissions sources, relative timing of model training and application, and the extent of extrapolation outside of parameter space encompassed by model training. In agreement with findings from our previous study that was focused on data from a single location (Casey et al., 2018), ANNs remained more effective than LMs for a number of these case studies but there were some exceptions. For CO<sub>2</sub> models, exceptions included case studies in which training data collection took place more than several months subsequent to the test data period. For O<sub>3</sub> models, exceptions included case studies in which the characteristics of dominant local emissions sources (oil and gas vs. urban) were significantly different at model training and testing locations. Among models that were tailored to case studies on an individual basis, O<sub>3</sub> ANNs performed better than O<sub>3</sub> LMs in six out of seven case studies, while CO<sub>2</sub> ANNs performed better than CO<sub>2</sub> LMs in three out of five case studies. The performance of O<sub>3</sub> models tended to be more sensitive to deployment location than to extrapolation in time, while the performance of CO<sub>2</sub> models tended to be more sensitive to extrapolation in time than to deployment location. The performance of O<sub>3</sub> ANN models benefited from the inclusion of several secondary metal-oxide-type sensors as inputs in five of seven case studies.</p>
url https://www.atmos-meas-tech.net/11/6351/2018/amt-11-6351-2018.pdf
work_keys_str_mv AT jgcasey testingtheperformanceoffieldcalibrationtechniquesforlowcostgassensorsinnewdeploymentlocationsacrossacountylineandacrosscolorado
AT mphannigan testingtheperformanceoffieldcalibrationtechniquesforlowcostgassensorsinnewdeploymentlocationsacrossacountylineandacrosscolorado
_version_ 1716819578203406336