Analysis of loading profile effect on testing machine calibration results

The paper presents an evaluation of the loading profile effect on the testing machine calibration. First, a 20 kN force transducer was calibrated in a force calibration machine. This transducer was then used for a number of calibration runs in a 600 kN material testing machine where the time step in...

Full description

Bibliographic Details
Main Author: Miha Hiti
Format: Article
Language:English
Published: Elsevier 2021-12-01
Series:Measurement: Sensors
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2665917421000945
id doaj-da5053a8b7b24f1083cf2b767726e867
record_format Article
spelling doaj-da5053a8b7b24f1083cf2b767726e8672021-09-21T04:10:11ZengElsevierMeasurement: Sensors2665-91742021-12-0118100131Analysis of loading profile effect on testing machine calibration resultsMiha Hiti0Slovenian National Building and Civil Engineering Institute (ZAG), Ljubljana, SloveniaThe paper presents an evaluation of the loading profile effect on the testing machine calibration. First, a 20 kN force transducer was calibrated in a force calibration machine. This transducer was then used for a number of calibration runs in a 600 kN material testing machine where the time step interval of the same loading profile was varied from 120 s to 0 s. Results show good agreement for most of the range but highlight an increasing error due to synchronization and filtering issues in measured signals when approaching very short step intervals and continuous loading.http://www.sciencedirect.com/science/article/pii/S2665917421000945Force calibrationLoading profileMeasurement uncertaintyContinuous loadingMaterial testing machines
collection DOAJ
language English
format Article
sources DOAJ
author Miha Hiti
spellingShingle Miha Hiti
Analysis of loading profile effect on testing machine calibration results
Measurement: Sensors
Force calibration
Loading profile
Measurement uncertainty
Continuous loading
Material testing machines
author_facet Miha Hiti
author_sort Miha Hiti
title Analysis of loading profile effect on testing machine calibration results
title_short Analysis of loading profile effect on testing machine calibration results
title_full Analysis of loading profile effect on testing machine calibration results
title_fullStr Analysis of loading profile effect on testing machine calibration results
title_full_unstemmed Analysis of loading profile effect on testing machine calibration results
title_sort analysis of loading profile effect on testing machine calibration results
publisher Elsevier
series Measurement: Sensors
issn 2665-9174
publishDate 2021-12-01
description The paper presents an evaluation of the loading profile effect on the testing machine calibration. First, a 20 kN force transducer was calibrated in a force calibration machine. This transducer was then used for a number of calibration runs in a 600 kN material testing machine where the time step interval of the same loading profile was varied from 120 s to 0 s. Results show good agreement for most of the range but highlight an increasing error due to synchronization and filtering issues in measured signals when approaching very short step intervals and continuous loading.
topic Force calibration
Loading profile
Measurement uncertainty
Continuous loading
Material testing machines
url http://www.sciencedirect.com/science/article/pii/S2665917421000945
work_keys_str_mv AT mihahiti analysisofloadingprofileeffectontestingmachinecalibrationresults
_version_ 1717373841684037632