An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems

<p><strong>Purpose: </strong>Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the stability of selected image parameters was assessed and evaluated for CBCT mo...

Full description

Bibliographic Details
Main Authors: Dennis N Stanley, Niko Papanikolaou, Alonso N Gutierrez
Format: Article
Language:English
Published: IJCTO 2014-03-01
Series:International Journal of Cancer Therapy and Oncology
Online Access:http://ijcto.org/index.php/IJCTO/article/view/124
id doaj-da20bc68f7714502b0cff4ea286ce871
record_format Article
spelling doaj-da20bc68f7714502b0cff4ea286ce8712020-11-24T22:16:58ZengIJCTOInternational Journal of Cancer Therapy and Oncology 2330-40492014-03-012274An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systemsDennis N Stanley0Niko Papanikolaou1Alonso N Gutierrez2The University of Texas Health Science Center San Antonio, San Antonio, TX, USA.The University of Texas Health Science Center San Antonio, San Antonio, TX, USA.The University of Texas Health Science Center San Antonio, San Antonio, TX, USA.<p><strong>Purpose: </strong>Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and the radiographic MV EPID mode.</p><p><strong>Methods and Materials</strong>: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For OBI CBCT, High quality head Full-Fan acquisition and Pelvis Half-Fan acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution, HU constancy and geometric distortion. Dose and kVp for the OBI were recorded using the Unfors RaySafe Xi system with the R/F High Detector for planar kV and the CT detector for CBCT. Dose for the MV EPID was recorded using a PTW975 Semiflex Ion Chamber, webline electrometer and 1cm SolidWater™.</p><p><strong>Results: </strong>For each metric, values were normalized to the mean and the standard deviations were recorded. <strong>Table 1</strong> shows the standard deviation for all results. Using this, tolerances can be reported as a warning threshold of 1σ and an action threshold of 2σ. <strong>Table 2</strong> shows the warning and action tolerances for the planar radiographic modalities while <strong>T</strong><strong>able 3 and 4</strong> show tolerance levels for the Full-Fan and Half-Fan, respectively.</p><p><strong>Conclusion</strong>: A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Varian OBI and EPID Imaging systems. The two systems show consistent imaging and dosimetric properties over the evaluated time frame.</p><p>----------------------------</p><p><strong>Cite this article as:</strong> Stanley DN, Papanikolaou N, Gutierrez AN. An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems. Int J Cancer Ther Oncol 2014; 2(2):020236.<strong> DOI: 10.14319/ijcto.0202.36</strong><br /><br /></p>http://ijcto.org/index.php/IJCTO/article/view/124
collection DOAJ
language English
format Article
sources DOAJ
author Dennis N Stanley
Niko Papanikolaou
Alonso N Gutierrez
spellingShingle Dennis N Stanley
Niko Papanikolaou
Alonso N Gutierrez
An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems
International Journal of Cancer Therapy and Oncology
author_facet Dennis N Stanley
Niko Papanikolaou
Alonso N Gutierrez
author_sort Dennis N Stanley
title An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems
title_short An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems
title_full An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems
title_fullStr An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems
title_full_unstemmed An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems
title_sort evaluation of the stability of image quality parameters of varian on-board imaging (obi) and epid imaging systems
publisher IJCTO
series International Journal of Cancer Therapy and Oncology
issn 2330-4049
publishDate 2014-03-01
description <p><strong>Purpose: </strong>Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and the radiographic MV EPID mode.</p><p><strong>Methods and Materials</strong>: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For OBI CBCT, High quality head Full-Fan acquisition and Pelvis Half-Fan acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution, HU constancy and geometric distortion. Dose and kVp for the OBI were recorded using the Unfors RaySafe Xi system with the R/F High Detector for planar kV and the CT detector for CBCT. Dose for the MV EPID was recorded using a PTW975 Semiflex Ion Chamber, webline electrometer and 1cm SolidWater™.</p><p><strong>Results: </strong>For each metric, values were normalized to the mean and the standard deviations were recorded. <strong>Table 1</strong> shows the standard deviation for all results. Using this, tolerances can be reported as a warning threshold of 1σ and an action threshold of 2σ. <strong>Table 2</strong> shows the warning and action tolerances for the planar radiographic modalities while <strong>T</strong><strong>able 3 and 4</strong> show tolerance levels for the Full-Fan and Half-Fan, respectively.</p><p><strong>Conclusion</strong>: A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Varian OBI and EPID Imaging systems. The two systems show consistent imaging and dosimetric properties over the evaluated time frame.</p><p>----------------------------</p><p><strong>Cite this article as:</strong> Stanley DN, Papanikolaou N, Gutierrez AN. An evaluation of the stability of image quality parameters of Varian on-board imaging (OBI) and EPID imaging systems. Int J Cancer Ther Oncol 2014; 2(2):020236.<strong> DOI: 10.14319/ijcto.0202.36</strong><br /><br /></p>
url http://ijcto.org/index.php/IJCTO/article/view/124
work_keys_str_mv AT dennisnstanley anevaluationofthestabilityofimagequalityparametersofvarianonboardimagingobiandepidimagingsystems
AT nikopapanikolaou anevaluationofthestabilityofimagequalityparametersofvarianonboardimagingobiandepidimagingsystems
AT alonsongutierrez anevaluationofthestabilityofimagequalityparametersofvarianonboardimagingobiandepidimagingsystems
AT dennisnstanley evaluationofthestabilityofimagequalityparametersofvarianonboardimagingobiandepidimagingsystems
AT nikopapanikolaou evaluationofthestabilityofimagequalityparametersofvarianonboardimagingobiandepidimagingsystems
AT alonsongutierrez evaluationofthestabilityofimagequalityparametersofvarianonboardimagingobiandepidimagingsystems
_version_ 1725787344403955712