Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint
This study examines the effect of common viscose damper on the behavior of adjacent reinforced concrete structures. For this purpose, three reinforced concrete 3, 5 and 7 floors buildings with a regular plan were selected and were compared in two cases without and with viscous dampers at the seams....
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Society of Polish Mechanical Engineers and Technicians
2017-09-01
|
Series: | Advances in Science and Technology Research Journal |
Subjects: | |
Online Access: | http://www.journalssystem.com/astrj/Evaluation-of-the-Reduction-of-Seismic-Response-of-Adjacent-Structures-Using-Viscous-Damper-Joint,70762,0,2.html |
id |
doaj-d9c7a2b47cbf41a1950e54124ae8ac5e |
---|---|
record_format |
Article |
spelling |
doaj-d9c7a2b47cbf41a1950e54124ae8ac5e2020-11-24T23:05:09ZengSociety of Polish Mechanical Engineers and TechniciansAdvances in Science and Technology Research Journal2080-40752299-86242017-09-01113314710.12913/22998624/7076270762Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper JointHamed Karbalay Malek0Kamal Emami1Department of Civil Engineering, Shabestar Branch, Islamic Azad University, Shabestar, IranDepartment of Civil Engineering, Shabestar Branch, Islamic Azad University, Shabestar, IranThis study examines the effect of common viscose damper on the behavior of adjacent reinforced concrete structures. For this purpose, three reinforced concrete 3, 5 and 7 floors buildings with a regular plan were selected and were compared in two cases without and with viscous dampers at the seams. They are designed based on discussions of Buildings Regulations 2800 and the 6 and 9 issues of Iranian National Building Regulations. Those buildings face under accelerograms of Bam, Mangil and El Centro, and then they are analyzed with nonlinear modal time history. This Accelerograms before applying to the structures, they are scaled based on the 2800 Regulations. Those buildings were modeled by SAP2000 finite element modeling software. Linear behavior of structural components of the structure and the non-linear behavior viscous damper were modeled. Finally, the seismic response of buildings includes the base shear force, up to a maximum lateral acceleration of seismic classes and classes for both with and without the viscous damper have been extracted and compared. The results showed the reduction in relative lateral displacement, maximum acceleration and base cut applied to structure in the presence of viscous dampers between two structures. This decline is not even in the direction that the viscous damper is viewed as significant.http://www.journalssystem.com/astrj/Evaluation-of-the-Reduction-of-Seismic-Response-of-Adjacent-Structures-Using-Viscous-Damper-Joint,70762,0,2.htmldriftseismic analysisMaximum accelerationviscous dampercutting foundationsreinforced concrete structure |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hamed Karbalay Malek Kamal Emami |
spellingShingle |
Hamed Karbalay Malek Kamal Emami Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint Advances in Science and Technology Research Journal drift seismic analysis Maximum acceleration viscous damper cutting foundations reinforced concrete structure |
author_facet |
Hamed Karbalay Malek Kamal Emami |
author_sort |
Hamed Karbalay Malek |
title |
Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint |
title_short |
Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint |
title_full |
Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint |
title_fullStr |
Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint |
title_full_unstemmed |
Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint |
title_sort |
evaluation of the reduction of seismic response of adjacent structures using viscous damper joint |
publisher |
Society of Polish Mechanical Engineers and Technicians |
series |
Advances in Science and Technology Research Journal |
issn |
2080-4075 2299-8624 |
publishDate |
2017-09-01 |
description |
This study examines the effect of common viscose damper on the behavior of adjacent reinforced concrete structures. For this purpose, three reinforced concrete 3, 5 and 7 floors buildings with a regular plan were selected and were compared in two cases without and with viscous dampers at the seams. They are designed based on discussions of Buildings Regulations 2800 and the 6 and 9 issues of Iranian National Building Regulations. Those buildings face under accelerograms of Bam, Mangil and El Centro, and then they are analyzed with nonlinear modal time history. This Accelerograms before applying to the structures, they are scaled based on the 2800 Regulations. Those buildings were modeled by SAP2000 finite element modeling software. Linear behavior of structural components of the structure and the non-linear behavior viscous damper were modeled. Finally, the seismic response of buildings includes the base shear force, up to a maximum lateral acceleration of seismic classes and classes for both with and without the viscous damper have been extracted and compared. The results showed the reduction in relative lateral displacement, maximum acceleration and base cut applied to structure in the presence of viscous dampers between two structures. This decline is not even in the direction that the viscous damper is viewed as significant. |
topic |
drift seismic analysis Maximum acceleration viscous damper cutting foundations reinforced concrete structure |
url |
http://www.journalssystem.com/astrj/Evaluation-of-the-Reduction-of-Seismic-Response-of-Adjacent-Structures-Using-Viscous-Damper-Joint,70762,0,2.html |
work_keys_str_mv |
AT hamedkarbalaymalek evaluationofthereductionofseismicresponseofadjacentstructuresusingviscousdamperjoint AT kamalemami evaluationofthereductionofseismicresponseofadjacentstructuresusingviscousdamperjoint |
_version_ |
1725627235622191104 |