Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score
Purpose: To investigate the factors that influence the success of labor induction with synthetic intravenous oxytocin infusion in term pregnancies with favourable Bishop score. Material and Methods: 150 pregnant women with completed 37 weeks of gestation and Bishop score>6 who had single and ceph...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Cukurova University
2015-06-01
|
Series: | Çukurova Üniversitesi Tıp Fakültesi Dergisi |
Subjects: | |
Online Access: | http://www.scopemed.org/fulltextpdf.php?mno=173483 |
id |
doaj-d99baffbe2274067899b12edbb915282 |
---|---|
record_format |
Article |
spelling |
doaj-d99baffbe2274067899b12edbb9152822020-11-25T00:59:57ZengCukurova UniversityÇukurova Üniversitesi Tıp Fakültesi Dergisi0250-51502015-06-01402317325173483Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop scoreMahmut Kuntay Kokanali0Demet Kokanali1Ali irfan Guzel2Hasan Onur Topcu3Sabri Cavkaytar4Melike Doganay5Zekai Tahir Burak Kadin Sagligi Egitim ve Arastirma Hastanesi/Ankara/Turkiye Zekai Tahir Burak Kadin Sagligi Egitim ve Arastirma Hastanesi/Ankara/Turkiye Zekai Tahir Burak Kadin Sagligi Egitim ve Arastirma Hastanesi/Ankara/Turkiye Zekai Tahir Burak Kadin Sagligi Egitim ve Arastirma Hastanesi/Ankara/Turkiye Zekai Tahir Burak Kadin Sagligi Egitim ve Arastirma Hastanesi/Ankara/Turkiye Zekai Tahir Burak Kadin Sagligi Egitim ve Arastirma Hastanesi/Ankara/TurkiyePurpose: To investigate the factors that influence the success of labor induction with synthetic intravenous oxytocin infusion in term pregnancies with favourable Bishop score. Material and Methods: 150 pregnant women with completed 37 weeks of gestation and Bishop score>6 who had single and cephalic presentation of pregnancy and were decided to underwent labor induction with intravenous oxytocin infusion were included in the study. Labor induction was considered unsuccessful if a vaginal delivery did not occur within 24 hours after the onset of loxytocin infusion or a cesarean section was performed during oxytocin infusion due to foetal distress, cephalopelvic disproportion or failure to progress in labor. Multivariable regression were used to identify odds of induction success. Results: Out of 150 women, induction of labor was unsuccessful in 23 (15.3%). Multivariate analysis demonstrated that nulliparity, shorter gestation period, persistent occiput posterior presentation and greater birth weight were independent risk factors for the induction failure. ROC curve analysis stated that gestation period of <270 days predict induction failure with a sensitivity of 60.9% and a spesificity of 92.9% while value of >3445-gram-birth weight has a sensitivity of 82.6% and a spesificity of 71.7% for the prediction of failure. Conclusion: Nulliparity, shorter gestation period, persistent occiput posterior presentation and greater birth weight increase the failure risk of labor induction with intravenous synthetic oxytocin infusion. [Cukurova Med J 2015; 40(2.000): 317-325]http://www.scopemed.org/fulltextpdf.php?mno=173483term pregnancybishop scoreoxytocinlabor induction |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mahmut Kuntay Kokanali Demet Kokanali Ali irfan Guzel Hasan Onur Topcu Sabri Cavkaytar Melike Doganay |
spellingShingle |
Mahmut Kuntay Kokanali Demet Kokanali Ali irfan Guzel Hasan Onur Topcu Sabri Cavkaytar Melike Doganay Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score Çukurova Üniversitesi Tıp Fakültesi Dergisi term pregnancy bishop score oxytocin labor induction |
author_facet |
Mahmut Kuntay Kokanali Demet Kokanali Ali irfan Guzel Hasan Onur Topcu Sabri Cavkaytar Melike Doganay |
author_sort |
Mahmut Kuntay Kokanali |
title |
Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score |
title_short |
Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score |
title_full |
Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score |
title_fullStr |
Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score |
title_full_unstemmed |
Analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score |
title_sort |
analysis of factors that influence the outcomes of labor induction with intravenous synthetic oxytocin infusion in term pregnancy with favourable bishop score |
publisher |
Cukurova University |
series |
Çukurova Üniversitesi Tıp Fakültesi Dergisi |
issn |
0250-5150 |
publishDate |
2015-06-01 |
description |
Purpose: To investigate the factors that influence the success of labor induction with synthetic intravenous oxytocin infusion in term pregnancies with favourable Bishop score.
Material and Methods: 150 pregnant women with completed 37 weeks of gestation and Bishop score>6 who had single and cephalic presentation of pregnancy and were decided to underwent labor induction with intravenous oxytocin infusion were included in the study. Labor induction was considered unsuccessful if a vaginal delivery did not occur within 24 hours after the onset of loxytocin infusion or a cesarean section was performed during oxytocin infusion due to foetal distress, cephalopelvic disproportion or failure to progress in labor. Multivariable regression were used to identify odds of induction success.
Results: Out of 150 women, induction of labor was unsuccessful in 23 (15.3%). Multivariate analysis demonstrated that nulliparity, shorter gestation period, persistent occiput posterior presentation and greater birth weight were independent risk factors for the induction failure. ROC curve analysis stated that gestation period of <270 days predict induction failure with a sensitivity of 60.9% and a spesificity of 92.9% while value of >3445-gram-birth weight has a sensitivity of 82.6% and a spesificity of 71.7% for the prediction of failure.
Conclusion: Nulliparity, shorter gestation period, persistent occiput posterior presentation and greater birth weight increase the failure risk of labor induction with intravenous synthetic oxytocin infusion. [Cukurova Med J 2015; 40(2.000): 317-325] |
topic |
term pregnancy bishop score oxytocin labor induction |
url |
http://www.scopemed.org/fulltextpdf.php?mno=173483 |
work_keys_str_mv |
AT mahmutkuntaykokanali analysisoffactorsthatinfluencetheoutcomesoflaborinductionwithintravenoussyntheticoxytocininfusionintermpregnancywithfavourablebishopscore AT demetkokanali analysisoffactorsthatinfluencetheoutcomesoflaborinductionwithintravenoussyntheticoxytocininfusionintermpregnancywithfavourablebishopscore AT aliirfanguzel analysisoffactorsthatinfluencetheoutcomesoflaborinductionwithintravenoussyntheticoxytocininfusionintermpregnancywithfavourablebishopscore AT hasanonurtopcu analysisoffactorsthatinfluencetheoutcomesoflaborinductionwithintravenoussyntheticoxytocininfusionintermpregnancywithfavourablebishopscore AT sabricavkaytar analysisoffactorsthatinfluencetheoutcomesoflaborinductionwithintravenoussyntheticoxytocininfusionintermpregnancywithfavourablebishopscore AT melikedoganay analysisoffactorsthatinfluencetheoutcomesoflaborinductionwithintravenoussyntheticoxytocininfusionintermpregnancywithfavourablebishopscore |
_version_ |
1725215107920691200 |