Case Report: A Novel Solution to Penile Zipper Injury—The Needle Holder

Penile injuries are relatively uncommon[1]. The crush injury mediated by entrapment of the skin between the teeth and fastener of a zipper mechanism has been described[2,3]. It is seen more commonly in uncircumcised children than adults[4]. A number of treatment methods have been mentioned in the li...

Full description

Bibliographic Details
Main Author: Philip A. McCann
Format: Article
Language:English
Published: Hindawi Limited 2005-01-01
Series:The Scientific World Journal
Online Access:http://dx.doi.org/10.1100/tsw.2005.39
Description
Summary:Penile injuries are relatively uncommon[1]. The crush injury mediated by entrapment of the skin between the teeth and fastener of a zipper mechanism has been described[2,3]. It is seen more commonly in uncircumcised children than adults[4]. A number of treatment methods have been mentioned in the literature[5,6]. An adult case presentation and novel method of management using two small needle holders is illustrated.