Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.

The specific aim of this study was to evaluate the feasibility, reproducibility and maturational changes of LV rotation, twist and torsion variables by real-time 3D speckle-tracking echocardiography (RT3DSTE) in children.A prospective study was conducted in 347 consecutive healthy subjects (181 male...

Full description

Bibliographic Details
Main Authors: Li Zhang, Jing Zhang, Wei Han, Jun Gao, Lin He, Yali Yang, Ping Yin, Mingxing Xie, Shuping Ge
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4948847?pdf=render
id doaj-d9045635c9c8492bb1515e1edb2d4d73
record_format Article
spelling doaj-d9045635c9c8492bb1515e1edb2d4d732020-11-25T02:47:43ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01117e015867910.1371/journal.pone.0158679Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.Li ZhangJing ZhangWei HanJun GaoLin HeYali YangPing YinMingxing XieShuping GeThe specific aim of this study was to evaluate the feasibility, reproducibility and maturational changes of LV rotation, twist and torsion variables by real-time 3D speckle-tracking echocardiography (RT3DSTE) in children.A prospective study was conducted in 347 consecutive healthy subjects (181 males/156 females, mean age 7.12 ± 5.3 years, and range from birth to 18-years) using RT 3D echocardiography (3DE). The LV rotation, twist and torsion measurements were made off-line using TomTec software. Manual landmark selection and endocardial border editing were performed in 3 planes (apical "2"-, "4"-, and "3"- chamber views) and semi-automated tracking yielded LV rotation, twist and torsion measurements. LV rotation, twist and torsion analysis by RT 3DSTE were feasible in 307 out of 347 subjects (88.5%).There was no correlation between rotation or twist and age, height, weight, BSA or heart rate, respectively. However, there was statistically significant, but very modest correlation between LV torsion and age (R2 = 0.036, P< 0.001). The normal ranges were defined for rotation and twist in this cohort, and for torsion for each age group. The intra-observer and inter-observer variabilities for apical and basal rotation, twist and torsion ranged from 7.3% ± 3.8% to 12.3% ± 8.8% and from 8.8% ± 4.6% to 15.7% ± 10.1%, respectively.We conclude that analysis of LV rotation, twist and torsion by this new RT3D STE is feasible and reproducible in pediatric population. There is no maturational change in rotation and twist, but torsion decreases with age in this cohort. Further refinement is warranted to validate the utility of this new methodology in more sensitive and quantitative evaluation of congenital and acquired heart diseases in children.http://europepmc.org/articles/PMC4948847?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Li Zhang
Jing Zhang
Wei Han
Jun Gao
Lin He
Yali Yang
Ping Yin
Mingxing Xie
Shuping Ge
spellingShingle Li Zhang
Jing Zhang
Wei Han
Jun Gao
Lin He
Yali Yang
Ping Yin
Mingxing Xie
Shuping Ge
Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.
PLoS ONE
author_facet Li Zhang
Jing Zhang
Wei Han
Jun Gao
Lin He
Yali Yang
Ping Yin
Mingxing Xie
Shuping Ge
author_sort Li Zhang
title Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.
title_short Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.
title_full Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.
title_fullStr Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.
title_full_unstemmed Three-Dimensional Rotation, Twist and Torsion Analyses Using Real-Time 3D Speckle Tracking Imaging: Feasibility, Reproducibility, and Normal Ranges in Pediatric Population.
title_sort three-dimensional rotation, twist and torsion analyses using real-time 3d speckle tracking imaging: feasibility, reproducibility, and normal ranges in pediatric population.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description The specific aim of this study was to evaluate the feasibility, reproducibility and maturational changes of LV rotation, twist and torsion variables by real-time 3D speckle-tracking echocardiography (RT3DSTE) in children.A prospective study was conducted in 347 consecutive healthy subjects (181 males/156 females, mean age 7.12 ± 5.3 years, and range from birth to 18-years) using RT 3D echocardiography (3DE). The LV rotation, twist and torsion measurements were made off-line using TomTec software. Manual landmark selection and endocardial border editing were performed in 3 planes (apical "2"-, "4"-, and "3"- chamber views) and semi-automated tracking yielded LV rotation, twist and torsion measurements. LV rotation, twist and torsion analysis by RT 3DSTE were feasible in 307 out of 347 subjects (88.5%).There was no correlation between rotation or twist and age, height, weight, BSA or heart rate, respectively. However, there was statistically significant, but very modest correlation between LV torsion and age (R2 = 0.036, P< 0.001). The normal ranges were defined for rotation and twist in this cohort, and for torsion for each age group. The intra-observer and inter-observer variabilities for apical and basal rotation, twist and torsion ranged from 7.3% ± 3.8% to 12.3% ± 8.8% and from 8.8% ± 4.6% to 15.7% ± 10.1%, respectively.We conclude that analysis of LV rotation, twist and torsion by this new RT3D STE is feasible and reproducible in pediatric population. There is no maturational change in rotation and twist, but torsion decreases with age in this cohort. Further refinement is warranted to validate the utility of this new methodology in more sensitive and quantitative evaluation of congenital and acquired heart diseases in children.
url http://europepmc.org/articles/PMC4948847?pdf=render
work_keys_str_mv AT lizhang threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT jingzhang threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT weihan threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT jungao threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT linhe threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT yaliyang threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT pingyin threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT mingxingxie threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
AT shupingge threedimensionalrotationtwistandtorsionanalysesusingrealtime3dspeckletrackingimagingfeasibilityreproducibilityandnormalrangesinpediatricpopulation
_version_ 1724751896991760384